Fisher 249 Displacer Level Sensor
Purchase options
Request a quote
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Fisher or Emerson.
Overview
Displacer level sensor for use with Fisher 2500 and DLC level instruments. Caged and cageless variants cover pressures from CL125 to CL2500 and bodies from NPS 1-1/2 up to NPS 8, in cast iron, steel and CF8M stainless.
Key specifications
- Line size range
- Caged NPS 1-1/2 and 2; cageless NPS 3, 4, 6 and 8 depending on type
- Pressure rating
- CL125/250 (249 cast iron) up to CL2500 (249L, ring-type joint); CL600 for 249B/249BF/249C; CL1500 for 249K
- Application
- Liquid level, interface level and density measurement on tanks and vessels
- Transmitter compatibility
- Fisher 2500 pneumatic level controllers and DLC digital level controllers
- Material of construction
- Cast iron, WCC or carbon steel, CF8M stainless steel, LCC; 249W wafer body for customer-supplied cage
- Sensor
- Displacer level sensor, caged and cageless, for Fisher 2500 and DLC level instruments
What the 249 measures
A displacer hangs from a torque tube inside the cage or the vessel. As liquid level, interface level or specific gravity changes, the buoyant force on the displacer changes, the torque tube twists, and that small rotation is what the 2500 or DLC instrument reads. Nothing in the sensor is electrical — the 249 is the mechanical half of the loop.
Caged or cageless
The caged body is a chamber the displacer sits in, isolated from turbulence and connected to the vessel by two nozzles. It is the right choice where the vessel is agitated, where a stilling well is needed, or where the instrument has to be serviced without emptying the tank. Cageless versions mount the displacer directly in the vessel through a single top or side connection, which suits clean service and small vessels where a cage would not fit.
Ratings that decide the model
The family spans a very wide pressure range: 249 in cast iron at CL125/250, 249B/249BF in WCC or carbon steel to CL600, 249C in CF8M to CL600, 249K at CL1500 and 249L at CL2500 with ring-type joint flanges. Cageless types 249BP/249CP/249P take NPS 3 to 8 bodies; 249VS is a side-mounted NPS 4 unit; 249W is a wafer body for a customer-supplied cage.
Choosing between them
Start from pressure class and material, then decide caged or cageless on the installation: agitation and service access push towards a cage, space and cost towards cageless. Displacer size and torque tube range are then selected against the process density and the instrument's span.
Specifications
| Attribute | Value |
|---|---|
| Line size range | Caged NPS 1-1/2 and 2; cageless NPS 3, 4, 6 and 8 depending on type |
| Pressure rating | CL125/250 (249 cast iron) up to CL2500 (249L, ring-type joint); CL600 for 249B/249BF/249C; CL1500 for 249K |
| Application | Liquid level, interface level and density measurement on tanks and vessels |
| Transmitter compatibility | Fisher 2500 pneumatic level controllers and DLC digital level controllers |
| Material of construction | Cast iron, WCC or carbon steel, CF8M stainless steel, LCC; 249W wafer body for customer-supplied cage |
| Sensor | Displacer level sensor, caged and cageless, for Fisher 2500 and DLC level instruments |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.