Fisher Cavitrol III Anti-Cavitation Trim
Purchase options
Request a quote
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Fisher or Emerson.
Overview
One-, two- and three-stage anti-cavitation cages for Fisher globe and angle bodies, NPS 1 to 24. Pressure drop capability to 99.3, 149 and 207 bar respectively, with FL 0.98 and 0.99 on the multi-stage cages.
Key specifications
- Line size range
- Fisher globe and angle bodies from NPS 1 to 24 (valve tables in the bulletin)
- Pressure rating
- Maximum pressure drop: one-stage 99.3 bar (1440 psi), two-stage 149 bar (2160 psi), three-stage 207 bar (3000 psi)
- Diagnostics
- Class IV standard on one-stage; Class V standard on two- and three-stage, higher classes optional
- Pressure range
- Recovery coefficient FL 0.98 on the two-stage and 0.99 on the three-stage cage
- Variants
- Cavitrol III one-, two- and three-stage anti-cavitation cages; linear characteristic, characterised cages on request
- Operating temperature (°C)
- One-stage -29 to 232 C (-20 to 450 F); multi-stage per bulletin table
The problem it solves
When a liquid valve drops pressure below the vapour pressure, bubbles form and then collapse — cavitation. The collapse happens against the trim and the body, removing metal and producing noise and vibration. The fix is not a harder material but a different pressure profile: split the total drop into stages so no single stage takes the liquid below its vapour pressure.
One, two or three stages
The stage count follows the pressure drop. One stage is rated to 99.3 bar (1440 psi), two stages to 149 bar (2160 psi) and three stages to 207 bar (3000 psi) — the extra stages are what keep each individual drop below the cavitation threshold. Flow is down, in through the cage openings and out through the seat ring, and the characteristic is linear with a standard cage, with characterised cages on request.
Recovery coefficient
FL is the number that predicts cavitation onset: the closer to 1.0, the less the trim recovers pressure downstream of the vena contracta and the more drop it can take before cavitating. The two-stage cage gives FL 0.98 and the three-stage 0.99 — near the practical maximum, which is exactly why these cages handle drops that would destroy a standard trim.
Bodies and shutoff
They fit Fisher globe and angle bodies from NPS 1 to 24 (valve tables in the bulletin). Shutoff is Class IV standard on the one-stage and Class V standard on the two- and three-stage cages, with higher classes optional. Temperature is -29 to 232 °C on the one-stage; multi-stage limits follow the bulletin table and figure, which must be checked against the body and bonnet chosen.
Specifications
| Attribute | Value |
|---|---|
| Line size range | Fisher globe and angle bodies from NPS 1 to 24 (valve tables in the bulletin) |
| Pressure rating | Maximum pressure drop: one-stage 99.3 bar (1440 psi), two-stage 149 bar (2160 psi), three-stage 207 bar (3000 psi) |
| Diagnostics | Class IV standard on one-stage; Class V standard on two- and three-stage, higher classes optional |
| Pressure range | Recovery coefficient FL 0.98 on the two-stage and 0.99 on the three-stage cage |
| Variants | Cavitrol III one-, two- and three-stage anti-cavitation cages; linear characteristic, characterised cages on request |
| Operating temperature (°C) | One-stage -29 to 232 C (-20 to 450 F); multi-stage per bulletin table |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer