Pilot-operated gas regulators for high pressure: inlet 1 to 100 bar, outlet set range 1 to 80 bar, allowable PS to 100 bar. EZH needs 1 bar minimum differential; EZHSO is the slam-shut version.
Key specifications
- Line size range
- Line sizes up to DN 200
- Pressure rating
- Allowable PS up to 100 bar; inlet pressure 1 to 100 bar
- Pressure range
- Minimum differential 1 bar (EZH); 3.8 bar on DN 25/50/80, 1.8 bar DN 100, 1 bar DN 150/200 (EZHSO)
- Measurement range
- Outlet set range 1 to 80 bar
- Glass membrane
- Maximum differential 99 bar (EZH) and 96.2 bar (EZHSO)
- Variants
- Pilot-operated pressure reducing regulator; EZHSO adds integral slam-shut
The high-pressure end of the range
Most gas regulators top out around 20 bar. The EZH covers inlet pressures from 1 to 100 bar and outlet set points from 1 to 80 bar, with an allowable PS of 100 bar — the range where a distribution regulator would need two stages and this one does it in one.
Why pilot-operated here
At 100 bar inlet, the force on a direct-operated diaphragm would be enormous and the regulator would need a spring that a person could not adjust. Pilot operation puts a small pilot in charge: it senses the outlet pressure and modulates the pressure on the main valve's actuator, so accurate control comes from a small, sensitive element while the main valve handles the flow and the pressure.
Differential requirements
The EZH needs a minimum differential of 1 bar to stroke fully. The EZHSO — the version with integral slam-shut — needs more: 3.8 bar on DN 25, 50 and 80, 1.8 bar on DN 100 and 1 bar on DN 150 and 200. That is a real constraint on station design: on a low-drop station the slam-shut version may simply not have enough differential to work.
Limits
Maximum differential is 99 bar on the EZH and 96.2 bar on the EZHSO. Sizes run to DN 200, which with the 100 bar rating covers transmission-level letdown as well as industrial high-pressure supply.
Specifications
| Attribute | Value |
|---|---|
| Line size range | Line sizes up to DN 200 |
| Pressure rating | Allowable PS up to 100 bar; inlet pressure 1 to 100 bar |
| Pressure range | Minimum differential 1 bar (EZH); 3.8 bar on DN 25/50/80, 1.8 bar DN 100, 1 bar DN 150/200 (EZHSO) |
| Measurement range | Outlet set range 1 to 80 bar |
| Glass membrane | Maximum differential 99 bar (EZH) and 96.2 bar (EZHSO) |
| Variants | Pilot-operated pressure reducing regulator; EZHSO adds integral slam-shut |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer