Fisher T205 Series Tank Blanketing Regulator
Purchase options
Request a quote
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Fisher or Emerson.
Overview
Tank blanketing regulator with seven spring ranges from 1 in. w.c. to 7 psig. Bodies 3/4 or 1 inch, inlet to 150 psig on gray iron and 200 psig on steel or stainless, in NPT or CL150/CL300/PN flanged.
Key specifications
- Line size range
- 3/4 or 1 in. (DN 20 or 25); 3/4 x 1 in. flanged uses the 3/4 in. body
- Pressure rating
- 150 psig / 10.3 bar maximum inlet on gray cast iron; 200 psig / 13.8 bar on steel or stainless
- Process connection
- NPT; CL150 RF, CL300 RF or PN 16/25/40 RF with welded flanges
- Measurement range
- 1 in. w.c. to 7 psig / 2.5 mbar to 0.48 bar across seven spring ranges
- Glass membrane
- Maximum outlet (casing) 35 psig / 2.4 bar on T205 and T205M gray iron; 75 psig / 5.2 bar on steel or stainless
- Application
- Tank blanketing on storage vessels holding oxidation- or moisture-sensitive liquids
What blanketing needs from a regulator
The pressure it holds is tiny — inches of water column on most tanks — but the supply behind it is a nitrogen or fuel gas header at 150 to 200 psig. A regulator that cannot hold a low set point against a high supply will either creep the tank pressure up until the relief valve lifts, or hunt as the tank breathes with temperature. The T205 is built for exactly that duty, with seven spring ranges covering 1 in. w.c. up to 7 psig.
Body and inlet ratings
3/4 and 1 inch bodies (DN 20 and 25), with the 3/4 x 1 inch flanged version using the 3/4 inch body. End connections are NPT, CL150 RF, CL300 RF or PN 16/25/40 RF with welded flanges. Maximum allowable inlet is 150 psig (10.3 bar) on gray cast iron and 200 psig (13.8 bar) on steel and stainless — the material choice sets the inlet rating, and the flanged ratings are lower again, so the combination has to be checked rather than assumed.
Casing limits
Maximum outlet (casing) pressure is 35 psig (2.4 bar) on the T205 and T205M in gray iron, and 75 psig (5.2 bar) in steel or stainless; the H versions carry their own figure. That casing limit, not the spring range, is what protects the regulator if the pilot or the seat fails — on a blanketing system it is the number that decides whether the tank's own relief is the next line of defence.
Where it is used
Storage tanks holding liquids that oxidize, absorb moisture or form a flammable atmosphere above the liquid: solvents, edible oils, chemicals and fuel. The regulator holds the pad gas at a set point just above atmospheric so air cannot enter through the vent.
Specifications
| Attribute | Value |
|---|---|
| Line size range | 3/4 or 1 in. (DN 20 or 25); 3/4 x 1 in. flanged uses the 3/4 in. body |
| Pressure rating | 150 psig / 10.3 bar maximum inlet on gray cast iron; 200 psig / 13.8 bar on steel or stainless |
| Process connection | NPT; CL150 RF, CL300 RF or PN 16/25/40 RF with welded flanges |
| Measurement range | 1 in. w.c. to 7 psig / 2.5 mbar to 0.48 bar across seven spring ranges |
| Glass membrane | Maximum outlet (casing) 35 psig / 2.4 bar on T205 and T205M gray iron; 75 psig / 5.2 bar on steel or stainless |
| Application | Tank blanketing on storage vessels holding oxidation- or moisture-sensitive liquids |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer