Fisher Type 99 Pilot-Operated Pressure Reducing Regulator
Purchase options
Request a quote
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Fisher or Emerson.
Overview
Pilot-operated reducing regulator in an NPS 2 body with a choice of five pilots. Inlet capability from 160 psig to 1000 psig depending on the pilot, and outlet settings from 2 in. w.c. to 100 psig.
Key specifications
- Line size range
- NPS 2 / DN 50
- Pressure rating
- 160 psig / 11.0 bar (61LD); 400 psig / 27.6 bar (61L, 61LE, 61H); 1000 psig / 69.0 bar (61HP)
- Process connection
- NPT, CL125 FF, CL150 RF, CL250 RF or CL300 RF
- Measurement range
- 2 in. w.c. to 100 psig / 5 mbar to 6.9 bar overall
- Glass membrane
- Maximum actuator pressure 100 psig operating, 110 psig emergency; maximum rated travel 1/4 in. (6.4 mm)
- Variants
- Pilot-operated with 61L, 61LD, 61LE, 61H or 61HP pilot
One body, five pilots
The Type 99 is a single NPS 2 body with the pilot doing the discrimination. The 61LD pilot holds the inlet to 160 psig and is the low-pressure option; 61L, 61LE and 61H cover 400 psig; the 61HP reaches 1000 psig. Outlet settings run from 2 in. w.c. all the way to 100 psig across the range, so the same body serves a burner train and a low-pressure blanketing duty depending on the pilot bolted to it.
Why pilot operation on NPS 2
A direct-operated regulator in an NPS 2 body would need a very large diaphragm and a heavy spring to hold accuracy at 1000 psig inlet. Pilot operation replaces that with a small, sensitive pilot controlling the pressure on the main valve's actuator: the accuracy comes from the pilot, the capacity from the main valve. On a 2-inch line with a 1000 psig source, that is the only practical arrangement.
Body and connections
NPS 2 / DN 50 in NPT, CL125 FF, CL150 RF, CL250 RF or CL300 RF. Maximum actuator pressure is 100 psig operating and 110 psig emergency, and maximum rated travel is 1/4 inch (6.4 mm) — a short stroke, which is why the main valve responds quickly to the pilot.
Sizing
Pick the pilot from the inlet pressure, then the spring from the outlet setting, then confirm the body rating and the actuator's 100 psig limit against the supply. Getting that order wrong is how a Type 99 ends up with a pilot that cannot reach the set point it was bought for.
Specifications
| Attribute | Value |
|---|---|
| Line size range | NPS 2 / DN 50 |
| Pressure rating | 160 psig / 11.0 bar (61LD); 400 psig / 27.6 bar (61L, 61LE, 61H); 1000 psig / 69.0 bar (61HP) |
| Process connection | NPT, CL125 FF, CL150 RF, CL250 RF or CL300 RF |
| Measurement range | 2 in. w.c. to 100 psig / 5 mbar to 6.9 bar overall |
| Glass membrane | Maximum actuator pressure 100 psig operating, 110 psig emergency; maximum rated travel 1/4 in. (6.4 mm) |
| Variants | Pilot-operated with 61L, 61LD, 61LE, 61H or 61HP pilot |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer