Micro Motion ELITE Coriolis Flow and Density Meter
Purchase options
From$4,289.08
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Micro Motion or Emerson.
Overview
Peak-accuracy Coriolis meter with 0.14 percent calibration uncertainty and very low pressure drop. Densities to 5 g/cm3, flow from 0.07 lb/min up to 120,000 lb/min, ISO/IEC 17025 calibrated.
Key specifications
- Measurement principle
- Coriolis, dual vibrating tube; mass flow and density from the same element
- Accuracy
- Calibration uncertainty 0.14 percent (ISO/IEC 17025); density accuracy 0.0005 g/cm3 (0.0002 optional)
- Wetted materials
- Drainable case; tube materials for sanitary and chloride-bearing service; case rating per ASME B31.3
- Diagnostics
- Smart Meter Verification with a verification record
- Pressure range
- Density range up to 5 g/cm3 (5,000 kg/m3)
- Measurement range
- Flow from 0.07 lb/min up to 120,000 lb/min (3,200 ton/hr) depending on tube design
The reference meter of the family
ELITE is the sensor Micro Motion positions at the top of its Coriolis range: calibrated on stands traceable to ISO/IEC 17025 with 0.14 percent uncertainty, and built so that its pressure drop is low enough to measure a low-pressure gas line or a gravity-fed liquid without a booster. That combination is why it turns up in custody transfer and allocation metering rather than only in process monitoring.
One platform, an enormous flow span
Tube designs cover 0.07 lb/min at the bottom — flavouring, vial filling, chemical injection — up to 120,000 lb/min (3,200 tons/hour) at the top for ship and railcar loading. The point is not the extremes individually but that the same transmitter family and the same diagnostics run across them, so a site with a pilot skid and a loading arm is not maintaining two technologies.
Density as a measurement, not a by-product
Density is accurate to 0.0005 g/cm3 (0.0002 optional) across a range up to 5 g/cm3, which makes the meter usable for concentration control and product identification, not just for correcting a volume figure. Repeatability of 0.0002 g/cm3 is what allows a batch to be released on density without a laboratory sample.
Materials for the hard services
The drainable case and the available tube materials are what let it sit in sanitary service and in produced fluids with chlorides. Case pressure ratings follow ASME B31.3, so the sensor can be specified against the same piping code as the line it is installed in rather than against a separate instrument standard.
Verification without a shutdown
Smart Meter Verification runs a comprehensive check of sensor and electronics against factory calibration while the process continues, and produces a record. On a custody meter that record is the difference between proving the meter is healthy on demand and waiting for the next calibration window.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Coriolis, dual vibrating tube; mass flow and density from the same element |
| Accuracy | Calibration uncertainty 0.14 percent (ISO/IEC 17025); density accuracy 0.0005 g/cm3 (0.0002 optional) |
| Wetted materials | Drainable case; tube materials for sanitary and chloride-bearing service; case rating per ASME B31.3 |
| Diagnostics | Smart Meter Verification with a verification record |
| Pressure range | Density range up to 5 g/cm3 (5,000 kg/m3) |
| Measurement range | Flow from 0.07 lb/min up to 120,000 lb/min (3,200 ton/hr) depending on tube design |
| Application | Custody transfer, ship and railcar loading, allocation, chemical injection and sanitary service |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer