Micro Motion H-Series Hygienic Coriolis Flow and Density Meter
Purchase options
From$3,062.65
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Micro Motion or Emerson.
Overview
Hygienic Coriolis sensor with drainable, cleanable tubes for sanitary service. 316L wetted parts, 3-A and EHEDG design, mass flow to 0.10 percent and density to 0.0005 g/cm3.
Key specifications
- Measurement principle
- Coriolis, dual vibrating tube; mass flow, volume flow, density and temperature
- Accuracy
- Mass flow 0.10-0.15 percent of rate; volume 0.15-0.25 percent; gas 0.50 percent; density 0.0005-0.002 g/cm3
- Process temperature
- -100 to 204 C (-150 to 400 F)
- Pressure rating
- 1450 psi (100 bar)
- Output signal
- 4-20 mA, HART, PROFIBUS-DP and FOUNDATION fieldbus via Micro Motion transmitters
- Wetted materials
- 316L stainless steel wetted parts; 3-A authorized and EHEDG certified design
Built for a line that has to be cleaned
Sanitary process lines are not cleaned around the instrument; the instrument has to survive the clean-in-place cycle and drain afterwards. The H-Series tube geometry is the design answer: the measuring tubes empty completely and there is no crevice where product can sit between batches, which is the property an EHEDG and 3-A review actually looks for.
Four measurements, one element
Mass flow, volume flow, density and temperature come from the same vibrating tube. Density is read from the tube's resonant frequency and mass flow from the phase shift between its ends, so a recipe change can be confirmed by density while the batch is measured by mass — no second instrument, no sampling.
Accuracy across the range
Mass flow accuracy is 0.10 to 0.15 percent of rate, volume flow 0.15 to 0.25 percent, gas flow 0.50 percent, and density 0.0005 to 0.002 g/cm3. Those are the figures that decide whether a filler can hit a declared net quantity without overfilling to compensate.
Materials and limits
Wetted parts are 316L stainless steel — the material a sanitary specification expects — with a temperature rating of -100 to 204 °C and a pressure rating of 1450 psi (100 bar). Smart Meter Verification checks the meter against its factory calibration while the line runs, which is what turns a calibration interval into a verification record rather than a shutdown.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Coriolis, dual vibrating tube; mass flow, volume flow, density and temperature |
| Accuracy | Mass flow 0.10-0.15 percent of rate; volume 0.15-0.25 percent; gas 0.50 percent; density 0.0005-0.002 g/cm3 |
| Process temperature | -100 to 204 C (-150 to 400 F) |
| Pressure rating | 1450 psi (100 bar) |
| Output signal | 4-20 mA, HART, PROFIBUS-DP and FOUNDATION fieldbus via Micro Motion transmitters |
| Wetted materials | 316L stainless steel wetted parts; 3-A authorized and EHEDG certified design |
| Diagnostics | Smart Meter Verification of calibration while the line runs |
| Application | Hygienic and sanitary service: food, beverage, dairy, pharmaceutical and biotech lines |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer