Endress+Hauser Proline Promag H 200 Electromagnetic Flow Meter
Purchase options
From$1,475.44
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Endress+Hauser.
Overview
The PROMAG H200 measures the volumetric flow of conductive liquids through a full-bore magnetic sensor: no moving parts, no pressure drop, and a reading that does not drift with viscosity, density or solids content.
Key specifications
- Process connection
- Electrical Connection: Thread NPT1/2
- Output signal
- Output: 4 to 20 mA HART, pulse/freq./switch output
- Certifications
- Approval: Non-hazardous area
- Measurement range
- Measuring range: 0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min)
- Application
- Application Package: Without
- Seal type
- Seal: Aseptic shape, EPDM
Magnetic measurement, no obstruction
The sensor is a lined tube with two electrodes; the transmitter drives a coil and reads the potential the flowing liquid generates. Because nothing protrudes into the stream, the meter handles slurries, pulp and media with fibres without clogging, and the only wear items are the liner and the electrodes.
Sizing and liner
Sizing is a velocity decision rather than a diameter decision: the line size sets the range, and the lining sets the temperature and chemical envelope. base price: $4,321.86; size 5/32in, DN04; approval Non-hazardous area; output 4 to 20 mA HART, pulse/freq./switch output (+$187.30).
What commissioning decides
Commissioning centres on the empty-pipe detection and the low-flow cut-off, both of which exist to stop the meter integrating noise when the line is dry or the pump is off. On a batching line, that is the difference between a repeatable batch and a totalizer that creeps overnight.
Specifications
| Attribute | Value |
|---|---|
| Process connection | Electrical Connection: Thread NPT1/2 |
| Output signal | Output: 4 to 20 mA HART, pulse/freq./switch output |
| Certifications | Approval: Non-hazardous area |
| Measurement range | Measuring range: 0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min) |
| Application | Application Package: Without |
| Seal type | Seal: Aseptic shape, EPDM |
| Sensor | Electrodes: 1.4435/316L |