Overview
The PROMASS P500 measures mass flow directly from the vibration of a flow tube, so the reading is unaffected by pressure, temperature, viscosity or a changing density profile in the product.
Mass, straight from the tube
Two tubes are driven at their resonance and the mass flowing through them twists the vibration; the phase difference between inlet and outlet is the mass flow, and the resonant frequency itself gives density. One sensor therefore reports mass, density, temperature and derived volume simultaneously.
What one sensor reports
That combination is what makes it useful on a custody or blending point: concentration follows from density, and a batch can be proved by mass rather than by a volume corrected with an assumed density.
Installation discipline
Installation rules are short but unforgiving — the tube must drain, the flanges must not be used to pull the pipe together, and a meter mounted where the line can empty will report the resulting gas slug as a density excursion rather than as a fault.