Endress+Hauser Proline Prosonic G 300 Ultrasonic Flowmeter
Purchase options
From$3,720.27
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Endress+Hauser.
Overview
The PROSONIC G300 times an acoustic signal across the pipe and derives velocity from the transit-time difference between upstream and downstream paths, with no obstruction in the flow.
Key specifications
- Process connection
- Electrical Connection: Thread NPT1/2
- Output signal
- Output and Input 1: 4-20mA HART
- Power supply
- Power Supply: 24VDC
- Certifications
- Approval Type: CSA
- Measurement range
- Measuring temperature range: -50° to 150°C (-58° to 302°F)
- Application
- Application Package: Advanced gas analysis
Transit time across the pipe
Clamp-on or in-line, the measurement principle is the same: the sound path length and the pipe geometry are known, so the time difference is a direct velocity measurement. Nothing wears because nothing is in contact with the moving fluid on a clamp-on installation.
Installation is the accuracy
The trade is installation discipline: couplant, pipe condition and the accuracy of the entered wall thickness and diameter all enter the result, and a clamp-on meter is only as good as the survey that placed it. base price: $11,722.52; size 1in; DN25; approval type CSA; approval, transmitter and sensor CSA C/US; Cl.I,II,III Div.1, XP, Gr.A-G (+$1,486.88).
Why clamp-on
On water distribution and energy metering the appeal is that the meter can be fitted to existing pipe without a shutdown, and moved later if the network is reconfigured.
Specifications
| Attribute | Value |
|---|---|
| Process connection | Electrical Connection: Thread NPT1/2 |
| Output signal | Output and Input 1: 4-20mA HART |
| Power supply | Power Supply: 24VDC |
| Certifications | Approval Type: CSA |
| Measurement range | Measuring temperature range: -50° to 150°C (-58° to 302°F) |
| Application | Application Package: Advanced gas analysis |
| Sensor | Measuring Tube, Transducer, and Sensor Version: 316L; Titanium Gr. 2; pressure + temperature measurement integrated |
Documents
No documents are published for this product yet.
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer