Overview
The PROSONIC FDU95 measures level from the transit time of an ultrasonic pulse through the air above the product, with no contact between the sensor and the liquid.
Key specifications
- Process connection
- Process Connection: Thread ANSI NPT1, UP
- Wetted materials
- Temperature, Blocking Distance and Material: -40 to 80°C/176°F, 70cm/2.3ft and membrane 316L, PE coated
- Certifications
- Approval: Non-hazardous area
- Measurement range
- Maximum measuring range: solids: 148ft (45m)
- Cable connection
- Cable Length: 20m/65ft
Sound, not contact
The sensor is mounted above the surface and the distance to the echo is converted to level using the speed of sound, which the integrated temperature sensor corrects continuously. Nothing wets, nothing fouls, and the measurement is unaffected by the dielectric constant of the product.
Vapour and surface
The limits are the vapour space and the surface: foam absorbs the pulse, heavy condensation can mask the transducer, and a strongly stratified atmosphere changes the speed of sound faster than the temperature correction tracks. base price: $2,454.62; approval Non-hazardous area; temperature, blocking distance and material -40 to 80°C/176°F, 70cm/2.3ft and membrane 316L, PE coated; process connection Thread ANSI NPT1, UP.
Open basins and sumps
It suits sumps, channels and open basins where a contacting instrument would need cleaning, and where the mounting can keep the sensor out of the fill stream.
Specifications
| Attribute | Value |
|---|---|
| Process connection | Process Connection: Thread ANSI NPT1, UP |
| Wetted materials | Temperature, Blocking Distance and Material: -40 to 80°C/176°F, 70cm/2.3ft and membrane 316L, PE coated |
| Certifications | Approval: Non-hazardous area |
| Measurement range | Maximum measuring range: solids: 148ft (45m) |
| Cable connection | Cable Length: 20m/65ft |
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.