Rosemount 0085 Pipe Clamp Sensor
Purchase options
From$78.23
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Non-intrusive pipe clamp RTD for surface temperature measurement: -50 to 300 C, pipe 1/2 in. to 60 in., spring-loaded element.
Key features
- Non-intrusive pipe clamp RTD sensor: measures pipe surface temperature without welding or penetrating the line
- Range -58 to 572 F (-50 to 300 C); fits pipe from 1/2 in. to 60 in. (22 to 1524 mm)
- Spring-loaded element pressed against the wall, so contact pressure holds as the pipe expands and contracts
- Single element 4-wire or dual element 3-wire RTD with silver tip
- Nipple-union extension in stainless steel with 1/2 in. NPT instrument connection, 80 mm or 150 mm, or sensor-only without extension
- Measures surface and ambient temperature, so a low-velocity gas line needs the wall-to-process difference considered
Key specifications
- Accuracy
- Range -58 to 572 F (-50 to 300 C); the element measures pipe wall temperature and infers the process, so a low velocity gas or partly filled line has to be assessed on wall-to-process difference, not on sensor accuracy alone
- Output signal
- RTD resistance to a transmitter or direct to the control system; single element 4-wire (P1) or dual element 3-wire (P2), both with a silver tip
- Diagnostics
- Contact pressure is the accuracy mechanism: a loose clamp leaves an air gap that adds thermal resistance, drifting the reading toward ambient and slowing the response, so the spring is what keeps the measurement repeatable
- Pressure range
- Not applicable to the sensor itself - it clamps to the outside of the pipe, so the line's pressure rating is unaffected and no process connection is required
- Variants
- Element P1 single 4-wire or P2 dual 3-wire; extension J nipple-union stainless steel with 1/2 in. NPT instrument connection at 3.1 in. (80 mm) or 5.9 in. (150 mm), or N for sensor only without extension
- Application
- Non-intrusive surface temperature measurement on existing pipe: retrofits, small bore lines where a thermowell would restrict flow, sanitary or non-penetrating installations, and temporary surveys along a line
Temperature without a hole in the pipe
The Rosemount 0085 pipe clamp sensor measures the surface temperature of a pipe from the outside. A stainless band wraps the pipe, a spring-loaded element is pressed against the wall, and the reading goes to a transmitter through a nipple-union extension. Nothing is welded, nothing is drilled, and the line does not have to be depressurised to fit it — which is why this is the sensor that goes onto pipe that is already running.
What it can and cannot measure
The published range is -58 to 572 °F (-50 to 300 °C), and the element sits on the outside of the wall. That distinction is the whole engineering question: a clamp sensor measures the pipe wall, and infers the process from it. Where the fluid is well mixed and the wall conducts well — water, steam condensate, a full liquid line — the wall tracks the process closely. Where the line is a gas at low velocity, or partly filled, or the ambient is very different from the process, the wall can sit a long way from the fluid temperature, and no amount of sensor accuracy fixes a measurement that is looking at the wrong surface.
Spring loading is the accuracy mechanism
The element is spring loaded against the pipe wall rather than simply resting in a clamp. That matters more than the RTD class: a loose clamp leaves an air gap, and an air gap is a thermal resistance in series with the measurement, so the reading drifts toward ambient and the response slows. The spring keeps contact pressure constant as the pipe expands and contracts through its temperature cycles, which is the difference between a sensor that reads the same next year and one that has to be re-tightened.
Sizes and elements
It fits pipe from ½ inch to 60 inches (22 to 1524 mm) diameter, in a range of band materials, so the same product covers a 15 mm impulse line and a 1.5 m duct. The element choices are a single element 4-wire or a dual element 3-wire RTD with a silver tip, both over the full range. Four-wire is the connection to specify where lead resistance would otherwise show up in the measurement; dual element is for a second transmitter or a redundant point on one clamp.
Extension and mounting
The extension is either a stainless nipple-union with a ½ inch NPT instrument connection, 3.1 in (80 mm) or 5.9 in (150 mm) long, or none at all for a sensor-only installation where the cable goes straight to a junction box. The taller extension exists for insulated lines — it lifts the head clear of the lagging so the cable entry and the transmitter are accessible without cutting the insulation back.
Where it fits
Retrofit temperature measurement on existing lines, small bore piping where a thermowell would be a restriction, sanitary or non-penetrating installations, and any point where the pipe cannot be opened. It is also the practical answer for temporary surveys: a set of these clamped along a line shows where the temperature actually goes before anyone commits to a welded thermowell.
Manufacturer reference: Rosemount 0085 Pipe Clamp Sensor Product Data Sheet, ordering information and specifications.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Range -58 to 572 F (-50 to 300 C); the element measures pipe wall temperature and infers the process, so a low velocity gas or partly filled line has to be assessed on wall-to-process difference, not on sensor accuracy alone |
| Output signal | RTD resistance to a transmitter or direct to the control system; single element 4-wire (P1) or dual element 3-wire (P2), both with a silver tip |
| Diagnostics | Contact pressure is the accuracy mechanism: a loose clamp leaves an air gap that adds thermal resistance, drifting the reading toward ambient and slowing the response, so the spring is what keeps the measurement repeatable |
| Pressure range | Not applicable to the sensor itself - it clamps to the outside of the pipe, so the line's pressure rating is unaffected and no process connection is required |
| Variants | Element P1 single 4-wire or P2 dual 3-wire; extension J nipple-union stainless steel with 1/2 in. NPT instrument connection at 3.1 in. (80 mm) or 5.9 in. (150 mm), or N for sensor only without extension |
| Application | Non-intrusive surface temperature measurement on existing pipe: retrofits, small bore lines where a thermowell would restrict flow, sanitary or non-penetrating installations, and temporary surveys along a line |
| Mounting | Stainless band clamped around the pipe from 1/2 in. to 60 in. (22 to 1524 mm); spring-loaded element pressed against the wall so contact pressure holds through thermal cycles, with no welding and no line shutdown |
| Operating temperature (°C) | -58 to 572 F (-50 to 300 C) at the clamp; the extension lifts the head clear of insulation on lagged lines |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer