Rosemount 0304 Conventional Manifold
Purchase options
From$165.64
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Conventional manifold for Rosemount pressure transmitters in traditional or wafer construction, with threaded or flanged side entries and PTFE packing rated to 6092 psi.
Key features
- Conventional manifold in traditional or wafer construction
- Threaded or flanged side process entries
- 2-, 3- and 5-valve configurations
- PTFE packing rated 6092 psi at 200 F, 4000 psi at 400 F
- Graphite options to 750 F wafer and 1000 F flanged
- POM seat option rated 4500 psi from -67 to 212 F
Key specifications
- Process temperature
- -40 to 200 F (-40 to 93 C) at full rating; PTFE to 400 F (204 C) at reduced rating; graphite wafer to 750 F (399 C); graphite flanged to 1000 F (538 C) stainless and 800 F (427 C) carbon steel; POM seat -67 to 212 F (-55 to 100 C)
- Pressure rating
- 6092 psi (420 bar) at -40 to 200 F with PTFE; 4000 psi (276 bar) at 400 F; graphite 1500 psi (103 bar) at 750 F wafer and 1000 F flanged; ASME graphite 3030 psi (209 bar) at 1000 F; POM seat 4500 psi (310 bar)
- Process connection
- Traditional body mounted on the traditional transmitter flange, 2 1/8 in (53.98 mm) centre-to-centre; wafer body sandwiched between flange faces; threaded or flanged side process entries
- Wetted materials
- 316 SST body with 316 SST trim; stainless or carbon steel flanged body options
- Variants
- Traditional (T) or wafer (W) style; G2 option, which limits maximum working pressure to 4500 psi (310 bar)
- Application
- Replacement of a traditional transmitter hook-up in chemical, refining, power and steam service
What the 0304 is
A conventional manifold: the instrument valve block that sits between the impulse piping and a pressure transmitter, in the familiar form plants have installed for decades. It comes in traditional (pipe-mounted, 2 1/8 in centre-to-centre) and wafer construction, with threaded or flanged side process entries, so an existing hook-up can be renewed with the same footprint.
Why conventional still matters
Not every installation can move to an integral manifold — the transmitter flange pattern, the pipe routing and the maintenance procedure are already fixed. A conventional manifold keeps that arrangement and still arrives leak checked and pressure tested as one assembly, which is the part a field-built stack cannot promise.
Traditional or wafer
The traditional body mounts on the transmitter flange with the pipe entries on the side; the wafer version sandwiches between flange faces and takes less depth. Both carry the same valve functions: block, equalise and vent in the 3- and 5-valve forms, block and vent in the 2-valve form.
Materials and limits
PTFE packing with an integral seat covers 6092 psi at -40 to 200 F (420 bar at -40 to 93 C) and 4000 psi at 400 F (276 bar at 204 C). Graphite packing reaches 1500 psi at 750 F as a wafer and at 1000 F as a flanged stainless body; the ASME B31.1/B31.3 graphite option is rated 3030 psi at 1000 F (209 bar at 538 C). A POM seat with PTFE packing is rated 4500 psi from -67 to 212 F, and the G2 option caps working pressure at 4500 psi (310 bar).
Where it fits
Chemical, refining, power and steam service where a conventional transmitter hook-up is the plant standard and the manifold has to match it.
Manufacturer reference: Emerson document 00813-0100-4733.
Specifications
| Attribute | Value |
|---|---|
| Process temperature | -40 to 200 F (-40 to 93 C) at full rating; PTFE to 400 F (204 C) at reduced rating; graphite wafer to 750 F (399 C); graphite flanged to 1000 F (538 C) stainless and 800 F (427 C) carbon steel; POM seat -67 to 212 F (-55 to 100 C) |
| Pressure rating | 6092 psi (420 bar) at -40 to 200 F with PTFE; 4000 psi (276 bar) at 400 F; graphite 1500 psi (103 bar) at 750 F wafer and 1000 F flanged; ASME graphite 3030 psi (209 bar) at 1000 F; POM seat 4500 psi (310 bar) |
| Process connection | Traditional body mounted on the traditional transmitter flange, 2 1/8 in (53.98 mm) centre-to-centre; wafer body sandwiched between flange faces; threaded or flanged side process entries |
| Wetted materials | 316 SST body with 316 SST trim; stainless or carbon steel flanged body options |
| Variants | Traditional (T) or wafer (W) style; G2 option, which limits maximum working pressure to 4500 psi (310 bar) |
| Application | Replacement of a traditional transmitter hook-up in chemical, refining, power and steam service |
| Valve configuration | 2-valve, 3-valve and 5-valve conventional configurations |
| Packing | PTFE as standard; graphite for high temperature, with a wafer and a flanged variant |
| Seat | Integral seat as standard; POM seat option with PTFE packing |
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer