Rosemount 102C Liquid Analysis Sensor Cable
No product images are published for this product yet.
Purchase options
From$59.64
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Sensor cable family for Rosemount liquid analysis: six types matched to sensor families, 4 to 200 ft, digital M12 or analog VP.
Key features
- Liquid analysis sensor cable family for Rosemount sensors, in lengths from 4 ft (1.2 m) to 200 ft (61 m)
- Six cable types, each matched to a sensor family: D1 digital M12 to M12, V6 contacting and amperometric, V8 analog/preamp pH/ORP, and E1 to E3 extensions
- V types start at the sensor with a VP connector and E types continue the run with wire leads at both ends, so a long run is a V plus one or more E cables
- The analog/preamp pH/ORP cable is not interchangeable with a conductivity or toroidal cable: a wet connector in a high impedance circuit behaves like a resistance in parallel, and the error appears as the slow drift people blame on a failing sensor
- For the digital M12 cable the female end goes to the sensor and the male end to the transmitter, which matters when the run is pulled through conduit
- Fine length steps from 4 to 200 ft exist to put the transmitter in a clean shelter while the sensor sits out at the basin
Key specifications
- Accuracy
- No measurement function of its own, but the cable is part of the circuit: the analog/preamp pH/ORP cable carries a high impedance signal, and a wet connector behaves like a resistance in parallel, producing the slow drift that is usually attributed to a failing sensor
- Output signal
- D1 digital sensor cable M12 female to M12 male. V6 and V8 analog sensor cables from a VP connector to wire leads. E1, E2 and E3 analog extension cables with wire leads at both ends, for pH/preamp, contacting and amperometric, and toroidal respectively
- Diagnostics
- Check the cable and connector before condemning a sensor: a probe that reads correctly on a short known good cable is not a failed probe. Keeping a spare of the type the site uses makes that test a swap rather than an investigation
- Pressure range
- Not applicable - a cable assembly with no process connection and no wetted parts beyond the sensor connector
- Variants
- Six cable types matched to sensor families, in lengths from 4 ft (1.2 m) through 5, 10, 15, 20, 25, 30, 33, 35, 40, 45, 50, 60, 66, 70, 80, 90, 100, 125, 150 and 175 ft up to 200 ft (61 m)
- Application
- Connecting Rosemount liquid analysis sensors to their transmitters where the two are separated: new installations and replacements of damaged, flooded or chewed cables on water and wastewater sites
The cable is part of the measurement, not part of the installation
The Rosemount 102C is the cable family for the Rosemount liquid analysis sensors, and it is not one cable. There are six types, each matched to a sensor family, in lengths from 4 ft (1.2 m) to 200 ft (61 m):
| Code | Cable |
|---|---|
| D1 | Digital sensor cable, M12 female to M12 male |
| V6 | Analog contacting and amperometric sensor cable, VP6 to wire leads |
| V8 | Analog/preamp pH/ORP sensor cable, VP8 to wire leads |
| E1 | Analog/preamp pH/ORP extension cable, wire leads to wire leads |
| E2 | Analog contacting and amperometric extension cable, wire leads to wire leads |
| E3 | Analog toroidal extension cable, wire leads to wire leads |
Read the list as three pairs rather than six products. For each analog sensor family there is a cable that starts at the sensor (the V types, with a VP connector at the sensor end) and a cable that continues the run (the E types, wire leads at both ends). The digital sensor needs neither, because its M12 connector and its own electronics do the job.
Why the type cannot be substituted
An analog pH sensor is a high impedance source, and the transmitter's preamplifier is what makes its signal usable. That is what the “analog/preamp” description in V8 and E1 means: this is the cable specified for that circuit, and it is not the same cable as the one for a contacting conductivity or amperometric sensor (V6, E2), nor the one for a toroidal sensor (E3).
The failure mode when the wrong one is used is not a dead instrument. It is a reading that is noisy, or that drifts slowly, or that responds to somebody touching the conduit. Those are the symptoms people attribute to a failing pH sensor, and a significant share of them are the cable — particularly a connector that has taken on moisture. A wet connector in a high impedance circuit behaves like a resistance in parallel with the measurement, and the resulting error appears gradually, in the same direction a fouled sensor drifts.
So the diagnostic habit worth having is to check the cable and the connector before condemning the sensor: a probe that reads correctly when connected with a short known-good cable is not a failed probe.
V plus E, not one long V
The V cable is the first length from the sensor; the E cable extends it. A long run is therefore built as a V cable plus one or more E cables, and every junction between them is a place where moisture and mechanical strain can enter the circuit.
That has a practical consequence for how the run is planned. Fewer, longer sections are better than several short ones joined in a wet area, and the junction between the sensor cable and the extension belongs in a dry enclosure rather than taped to a handrail over a basin. On a 200 ft run out to a settlement tank, the joints are the part of the installation that will be attended to again.
The M12 rule, for the digital cable
For digital sensor cables with M12 connectors, the connection is directional: the female end goes to the sensor and the male end goes to the transmitter. That is worth stating because a pre-made cordset cannot be reversed, and a cable pulled through a conduit the wrong way round is discovered at the far end with the run already made off.
Lengths, and what the length is for
The length list runs in fine steps — 4, 5, 10, 15, 20, 25, 30, 33, 35, 40, 45, 50, 60, 66, 70, 80, 90, 100, 125, 150, 175 and 200 ft — which tells you what these lengths are for. They exist to let a transmitter sit in a clean, accessible shelter while its sensor sits out at the basin, the channel or the tank, which is the normal layout on a water or wastewater site. Choose the length from the routed path with a service loop, not from the straight-line distance, and remember that a long run of analog signal is a longer antenna for whatever electrical noise the site has.
Where it fits
New installations where the sensor and the transmitter are separated, and replacements where a cable has been damaged, flooded or chewed. Order the cable with the sensor rather than after it — the V type has to match the sensor's connector and circuit, and the E type has to match the V — and keep one spare of the type the site actually uses, because a cable failure presents as a measurement failure and the fastest way to prove which one it is, is to swap the cable.
Manufacturer reference: Rosemount 102C Liquid Analysis Sensor Cable Product Data Sheet for cable types, connectors, length codes and the wiring references for each sensor family.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | No measurement function of its own, but the cable is part of the circuit: the analog/preamp pH/ORP cable carries a high impedance signal, and a wet connector behaves like a resistance in parallel, producing the slow drift that is usually attributed to a failing sensor |
| Output signal | D1 digital sensor cable M12 female to M12 male. V6 and V8 analog sensor cables from a VP connector to wire leads. E1, E2 and E3 analog extension cables with wire leads at both ends, for pH/preamp, contacting and amperometric, and toroidal respectively |
| Diagnostics | Check the cable and connector before condemning a sensor: a probe that reads correctly on a short known good cable is not a failed probe. Keeping a spare of the type the site uses makes that test a swap rather than an investigation |
| Pressure range | Not applicable - a cable assembly with no process connection and no wetted parts beyond the sensor connector |
| Variants | Six cable types matched to sensor families, in lengths from 4 ft (1.2 m) through 5, 10, 15, 20, 25, 30, 33, 35, 40, 45, 50, 60, 66, 70, 80, 90, 100, 125, 150 and 175 ft up to 200 ft (61 m) |
| Application | Connecting Rosemount liquid analysis sensors to their transmitters where the two are separated: new installations and replacements of damaged, flooded or chewed cables on water and wastewater sites |
| Mounting | A long run is built as a V cable from the sensor plus one or more E cables, so the number of junctions is a design choice. For the digital M12 cable, the female end connects to the sensor and the male end to the transmitter |
| Operating temperature (°C) | Set by the cable construction and the installation environment. Junctions between a sensor cable and an extension belong in a dry enclosure rather than exposed over a basin |