Rosemount 1066 Single Channel Transmitter
Purchase options
From$896.94
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Loop-powered single channel liquid analysis transmitter for pH/ORP, conductivity and amperometric sensors, with a 4-20 mA output and HART or Fieldbus communication.
Key features
- Loop-powered single channel transmitter for liquid analysis
- Accepts pH/ORP, contacting and toroidal conductivity, and amperometric sensors (DO, free and total chlorine, monochloramine, ozone)
- 4-20 mA output with HART, FOUNDATION Fieldbus or Fieldbus with FISCO
- Polycarbonate enclosure, Type 4X and IP66, 155 x 155 x 131 mm
- Intrinsically safe to Class I/II/III Div 1 and ATEX/IECEx Ex ia IIC T4 Ga
- Displays measurement, temperature and diagnostics on a 128 x 96 LCD
Key specifications
- Enclosure rating
- Polycarbonate enclosure, Type 4X and IP66, with 1/2 in or PG 13.5 conduit openings
- Output signal
- 4-20 mA loop-powered output; HART digital communication, or FOUNDATION Fieldbus including a FISCO variant for intrinsically safe segments
- Power supply
- Loop powered, 12.7 Vdc minimum; 250 Ohm external load resistor required for HART communication
- Diagnostics
- Displays the analytical measurement, temperature and diagnostics on a 128 x 96 monochrome LCD with a membrane keypad (MENU, DIAG, EXIT and a four-way keypad)
- Certifications
- Intrinsically safe Class I, II and III Division 1 Groups A-G with an appropriate barrier; ATEX/IECEx Ex ia IIC T4 Ga including Class I Zone 0, ambient -20 to 65 °C
- Measurement range
- Accepts pH/ORP, contacting and toroidal conductivity, and amperometric sensors: dissolved oxygen, free chlorine, total chlorine, monochloramine and ozone
One analyzer channel, loop powered
The 1066 is a single-channel liquid analysis transmitter: it takes one analytical sensor, displays the measurement and temperature, and puts the result on a 4-20 mA loop. It is the box between a pH, conductivity or amperometric sensor and the control system, and the choice of which sensor it serves is made by the input card and the programming, not by the front panel.
What it accepts
pH and ORP, contacting and toroidal conductivity, and the amperometric family — dissolved oxygen, free chlorine, total chlorine, monochloramine and ozone. That breadth is the point: a plant standardising on one transmitter model can cover a water treatment room, a chlorination point and a conductivity loop with the same spare on the shelf. The amperometric sensors are the ones that need the most care, because their readings depend on flow and on membrane condition, and the transmitter is where those diagnostics surface.
Loop power and communication
It is loop powered, 12.7 Vdc minimum, with a 250 Ω external load resistor when HART is used — the detail that catches people wiring a transmitter to a low-impedance input and finding the digital signal will not communicate. HART and FOUNDATION Fieldbus variants exist, including a Fieldbus version with FISCO for intrinsically safe segments.
The enclosure
Polycarbonate, Type 4X and IP66, with ½ in or PG 13.5 conduit entries, 155 mm square and 131 mm deep. That is a wall-mount box for a plant room or a skid, not a field hockey-puck, and the display is a 128 x 96 monochrome LCD with no backlight — readable in ordinary indoor light, and honest about what it is.
Hazardous areas
Intrinsically safe to Class I, II and III Division 1 Groups A-G with the appropriate barrier, and to ATEX/IECEx Ex ia IIC T4 Ga including Zone 0, at an ambient of -20 to 65 °C. The barrier and the entity parameters are part of that approval — the transmitter alone does not make a safe loop.
Where it fits
Water and wastewater treatment, cooling and boiler water, chlorination and dechlorination points, and any single analytical measurement that has to reach a PLC or DCS as a 4-20 mA signal.
Manufacturer reference: Rosemount 1066 Single Channel Transmitter Product Data Sheet, LIQ-PDS-1066.
Specifications
| Attribute | Value |
|---|---|
| Enclosure rating | Polycarbonate enclosure, Type 4X and IP66, with 1/2 in or PG 13.5 conduit openings |
| Output signal | 4-20 mA loop-powered output; HART digital communication, or FOUNDATION Fieldbus including a FISCO variant for intrinsically safe segments |
| Power supply | Loop powered, 12.7 Vdc minimum; 250 Ohm external load resistor required for HART communication |
| Diagnostics | Displays the analytical measurement, temperature and diagnostics on a 128 x 96 monochrome LCD with a membrane keypad (MENU, DIAG, EXIT and a four-way keypad) |
| Certifications | Intrinsically safe Class I, II and III Division 1 Groups A-G with an appropriate barrier; ATEX/IECEx Ex ia IIC T4 Ga including Class I Zone 0, ambient -20 to 65 °C |
| Measurement range | Accepts pH/ORP, contacting and toroidal conductivity, and amperometric sensors: dissolved oxygen, free chlorine, total chlorine, monochloramine and ozone |
| Application | Single channel liquid analysis transmitter that puts one analytical measurement on a 4-20 mA loop for a PLC or DCS |
| Dimensions | 6.10 in L x 6.10 in W x 5.45 in H (155 x 155 x 131 mm); 2 lb (1 kg) net, 3 lb (1.5 kg) shipping weight |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer