Overview

Barstock thermowells in threaded, flanged, welded and Van Stone versions, with R21 calculations to ASME PTC 19.3 TW-2016.

Key features

  • Barstock thermowell machined from solid bar, installed as a pressure-tight part of the pipe or vessel
  • Head length H plus immersion length U equals the sensor insertion length L - the dimension that decides fit
  • Immersion guidance: 10x root diameter in air or gas, 5x in liquids, at least one third into the pipe, API element length plus 50 mm
  • Threaded, flanged, welded and Van Stone connection families; straight, stepped and tapered stem profiles
  • 316/316L, 304/304L and A105 standard, with Alloy C-276, Alloy 600 and duplex grades available
  • R21 thermowell calculation report supplied against ASME PTC 19.3 TW-2016 for wake frequency and drag

Key specifications

Accuracy
Not a measuring device itself; accuracy depends on immersion - 10x the root diameter in air or gas, 5x in liquids, at least one third into the pipe, with the tip near the centreline in turbulent flow
Output signal
Mechanical interface only: head length H plus immersion length U equals the sensor insertion length L, which must match the 214C sensor ordered with it
Diagnostics
R21 thermowell calculation report supplied against ASME PTC 19.3 TW-2016, covering drag force and wake frequency, the fatigue mechanism that governs whether a well survives its flow
Pressure range
The thermowell is a wetted pressure-retaining part, so its rating follows the selected process connection (threaded, flanged, welded or Van Stone) and the material rather than a single blanket figure
Variants
Threaded, flanged, welded and Van Stone connection families; straight, stepped and tapered stem profiles; design modifiers for root, tip and bore diameter and for tip thickness
Application
Isolating a temperature sensor from flow-induced stress, pressure and corrosive chemistry in pipe or vessel service, so the sensor can be removed for calibration without a shutdown
See all specifications