Rosemount 114C Thermowells
Purchase options
From$58.85
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Barstock thermowells in threaded, flanged, welded and Van Stone versions, with R21 calculations to ASME PTC 19.3 TW-2016.
Key features
- Barstock thermowell machined from solid bar, installed as a pressure-tight part of the pipe or vessel
- Head length H plus immersion length U equals the sensor insertion length L - the dimension that decides fit
- Immersion guidance: 10x root diameter in air or gas, 5x in liquids, at least one third into the pipe, API element length plus 50 mm
- Threaded, flanged, welded and Van Stone connection families; straight, stepped and tapered stem profiles
- 316/316L, 304/304L and A105 standard, with Alloy C-276, Alloy 600 and duplex grades available
- R21 thermowell calculation report supplied against ASME PTC 19.3 TW-2016 for wake frequency and drag
Key specifications
- Accuracy
- Not a measuring device itself; accuracy depends on immersion - 10x the root diameter in air or gas, 5x in liquids, at least one third into the pipe, with the tip near the centreline in turbulent flow
- Output signal
- Mechanical interface only: head length H plus immersion length U equals the sensor insertion length L, which must match the 214C sensor ordered with it
- Diagnostics
- R21 thermowell calculation report supplied against ASME PTC 19.3 TW-2016, covering drag force and wake frequency, the fatigue mechanism that governs whether a well survives its flow
- Pressure range
- The thermowell is a wetted pressure-retaining part, so its rating follows the selected process connection (threaded, flanged, welded or Van Stone) and the material rather than a single blanket figure
- Variants
- Threaded, flanged, welded and Van Stone connection families; straight, stepped and tapered stem profiles; design modifiers for root, tip and bore diameter and for tip thickness
- Application
- Isolating a temperature sensor from flow-induced stress, pressure and corrosive chemistry in pipe or vessel service, so the sensor can be removed for calibration without a shutdown
The part that lets you pull a sensor out of a live process
The Rosemount 114C is a barstock thermowell — a closed-end metal tube machined from solid bar, installed into the pipe or vessel so that it becomes a pressure-tight part of it. The sensor sits inside the well, not in the process. That buys two things that matter every week in a plant: the sensor is protected from flow-induced stress, pressure and corrosive chemistry, and it can be removed for calibration or replacement without a shutdown and without draining the line.
The one dimension that decides whether it fits
The 114C is ordered to a length, and the length is not chosen by feel. The relationship is head length (H) plus immersion length (U) equals the sensor's insertion length (L). Get it wrong in the short direction and the sensor tip sits off the bottom of the well, measuring the well's air gap instead of the process; get it wrong in the long direction and the sensor is stressed against the well tip. The 214C sensor family is ordered to the same insertion length, which is why the thermowell and the sensor are normally specified together.
How deep the well should go
There is no universal formula, but the industry practice is specific: 10 times the root diameter for air or gas, 5 times for liquids, with a minimum of one third of the way into the pipe, and the API recommendation of the sensing element length plus 50 mm (2 inches). The ideal is a tip near the centreline in turbulent flow, because that is where the temperature is actually representative rather than a reading of the boundary layer.
Four ways to mount it
Threaded, flanged, welded and Van Stone are the standard configurations, and the process designer usually fixes which one before the instrument engineer sees the line: threaded for small lines and low duty, flanged for larger pipes and higher ratings, welded where a leak path is unacceptable, and Van Stone where the wetted material has to differ from the flange material. The well is a wetted pressure part, so temperature, pressure and material all have to be adequate for the connection chosen — this is not the place to reuse a spare because it threads in.
Stem profile is a mechanical decision
Straight, stepped and tapered stems are available, and the choice is driven by four things: process pressure, how fast the measurement has to respond, the drag force of the flow on the well, and the wake frequency. A tapered stem sheds vortex shedding better in fast flow; a stepped stem gives a faster response for a given root diameter; a straight stem is the simplest and the strongest at the root. This is where a thermowell stops being a tube and becomes a structure.
The calculation is part of the product
Emerson supplies an R21 thermowell calculation report against ASME PTC 19.3 TW-2016, the standard that defines the qualitative calculations for whether a well will survive the flow it sits in. That matters because thermowell failures are fatigue failures at the root caused by vortex shedding, and they are progressive: a well that is marginal in the calculation works for months and then leaves with the process. The report is the evidence that this well, at this length, in this flow, is inside the standard.
Materials
Standard materials are 316/316L stainless, 304/304L stainless and A105 carbon steel, with Alloy C-276, Alloy 600 and duplex grades available for corrosive service. The design modifiers allow different root, tip and bore diameters and different tip thickness, so the well can be tuned to the sensor and to the flow rather than only picked from a table.
Where it fits
Every temperature point that is measured with a sensor that has to be removable: process lines in chemical and refining service, steam and condensate, tanks, and any location where the fluid would attack or stress the sensor directly. It is ordered with the sensor and the transmitter as a set — head length plus immersion length plus insertion length is the whole specification.
Manufacturer reference: Rosemount 114C Thermowells Product Data Sheet 00813-0200-4952 Rev DB, selection guide and ordering information.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not a measuring device itself; accuracy depends on immersion - 10x the root diameter in air or gas, 5x in liquids, at least one third into the pipe, with the tip near the centreline in turbulent flow |
| Output signal | Mechanical interface only: head length H plus immersion length U equals the sensor insertion length L, which must match the 214C sensor ordered with it |
| Diagnostics | R21 thermowell calculation report supplied against ASME PTC 19.3 TW-2016, covering drag force and wake frequency, the fatigue mechanism that governs whether a well survives its flow |
| Pressure range | The thermowell is a wetted pressure-retaining part, so its rating follows the selected process connection (threaded, flanged, welded or Van Stone) and the material rather than a single blanket figure |
| Variants | Threaded, flanged, welded and Van Stone connection families; straight, stepped and tapered stem profiles; design modifiers for root, tip and bore diameter and for tip thickness |
| Application | Isolating a temperature sensor from flow-induced stress, pressure and corrosive chemistry in pipe or vessel service, so the sensor can be removed for calibration without a shutdown |
| Mounting | Selected to match the mating connection the process designer specifies; the well becomes a pressure-tight integral part of the vessel or pipe when installed |
| Operating temperature (°C) | Dependent on material: 316/316L and 304/304L stainless, A105 carbon steel as standard, with Alloy C-276, Alloy 600 and duplex grades for corrosive or high temperature service |
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer