Overview
M12 A-code 4-pin cordsets for the 1208 in 2 to 50 m, general purpose IP66/IP68 or Ex-rated IP68/IP69K (E01-E03) for hazardous locations.
Key features
- M12 A-coded 4-pin cable assemblies for the Rosemount 1208, in 2, 5, 10, 20 and 50 m lengths
- Only cable options E01, E02 and E03 are suitable for installation in hazardous locations - the cable is part of the approval, not an accessory to it
- The Ex family is also the tougher one at IP68/IP69K against IP66/IP68, and it comes only as angled to unterminated in 5, 20 and 50 m
- The M12 end is factory moulded, which is where the ingress rating comes from; the open end is terminated in a dry junction box, which is why unterminated is the normal option
- A-coded 4-pin coding is deliberate: a D-coded lead is the same size and will not mate, which is what stops a network cable being used on a sensor port
- Cutting the connector off to pull the cable through conduit throws the IP rating away
Key specifications
- Accuracy
- No measurement function. On a 4-20 mA loop a long run adds resistance and voltage drop, which shows up as a reading slightly low at full scale if the supply is marginal
- Output signal
- M12 A-coded 4-pin assemblies: M12 female angled or straight at the instrument, to an M12 male straight or an unterminated end for termination in a junction box
- Diagnostics
- Only cable options E01, E02 and E03 are suitable for installation in hazardous locations, so the cable is part of the approval rather than an accessory to it. Cutting the moulded connector off to pull a cable through conduit discards the IP rating
- Pressure range
- Not applicable - a cable assembly with no process connection and no wetted parts
- Variants
- General purpose codes C01 to C17 across straight and angled connectors, terminated and unterminated ends, at 2, 5, 10, 20 and 50 m. Hazardous location versions E01 (5 m), E02 (20 m) and E03 (50 m), all M12 female angled to unterminated. Accessory number 01208-5000-0024
- Application
- Connecting the Rosemount 1208 transmitter to a host or junction box over a moulded M12 cordset, in general purpose and hazardous location installations
The cable is part of the approval, not a consumable
The Rosemount 1208 cable assemblies are M12 A-coded, 4-pin cordsets that connect the transmitter to its host. They come in two electrically similar but administratively different families, and the datasheet states the rule in one line:
Only cable options E01, E02 and E03 are suitable for installation in hazardous locations.
That sentence makes the cable part of the certification rather than an accessory to it. A 1208C in a Zone 2 area wired with one of the general-purpose C-series cables is outside its approval — the transmitter is certified, the cable is not, and the assembly the approver looks at is the installation, not the instrument alone.
Two families, and the Ex one is also the tougher one
| C-series (general purpose) | E-series (hazardous locations) | |
|---|---|---|
| Suitability | Non Ex | Hazardous locations, Zone 2 / Division 2 |
| Ingress rating | IP66 / IP68 | IP68 / IP69K |
| Connector ends | M12 female angled or straight, either to an M12 male straight or unterminated | M12 female angled, unterminated |
| Lengths | 2, 5, 10, 20 and 50 m | E01 5 m, E02 20 m, E03 50 m |
The Ex family is not simply the general-purpose cable with a certificate attached. It carries the higher ingress rating, IP69K in addition to IP68 — protection against high-pressure, high-temperature jet washing — and it is offered in fewer configurations: angled connector, unterminated far end, three lengths. There is no straight version and no 2 m version, so an Ex installation has to be designed around those options rather than choosing the convenient length and hoping.
Why "unterminated" is the normal option
The M12 end of these assemblies is factory-moulded, which is where the ingress rating comes from. The other end is deliberately left open so it can be terminated in a junction box or a control panel — that is, in a dry place where a field-made connection is acceptable.
This is the practical difference between a moulded cordset and a cable glanded into the transmitter. A gland is a mechanical seal made on site, and its IP rating depends entirely on how well it was made; a moulded M12 coupling ring that is screwed down is a seal made in a factory. That is why the transmitter uses an M12 connection in the first place, and why a site that cuts the connector off to pull the cable through a conduit has thrown the rating away.
Coding: A-code, 4-pin
These are A-coded 4-pin assemblies. M12 coding is not cosmetic — a D-coded connector is physically the same size and will not mate with the wrong socket, which is precisely the point: it prevents an Ethernet cable being plugged into a sensor port, and it prevents a sensor cordset being used where a network cable was intended. On an IO-Link installation, A-coded is the correct coding for the device port, and a B-coded or D-coded lead in the stores is a lead that will not fit.
Choosing the length
Reach the nearest junction box or marshalling point with a service loop, and no further. On a 4–20 mA loop a long run adds resistance and, if the supply is marginal, a voltage drop that shows up as a reading that is slightly low at full scale. On the IO-Link version the run is bounded by the interface rather than by the analog loop, but the same principle applies: the shortest cable that routes properly is the right one, and a 50 m cordset used to span 6 m is a spare part nobody can reuse.
Accessory part numbers
The general-purpose codes run C01 to C17 across straight and angled connectors, terminated and unterminated ends, at 2, 5, 10, 20 and 50 m. The hazardous-location versions are E01 (5 m), E02 (20 m) and E03 (50 m), all M12 female angled to unterminated, rated IP68/IP69K.
Where it fits
New installations where the transmitter is a few metres from a junction box, and replacements where a cordset has been damaged at the coupling ring — the moulded end is the part that fails, and it is not repairable. Order with the transmitter rather than afterwards, and state whether the installation is a hazardous location, because that single answer decides which family is permissible and there is no overlap between them.
Manufacturer reference: Rosemount 1208 Level and Flow Transmitter Series Product Data Sheet 00813-0200-7062, cable options, for the C-series and E-series codes, ingress ratings and the hazardous-location limitation.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | No measurement function. On a 4-20 mA loop a long run adds resistance and voltage drop, which shows up as a reading slightly low at full scale if the supply is marginal |
| Output signal | M12 A-coded 4-pin assemblies: M12 female angled or straight at the instrument, to an M12 male straight or an unterminated end for termination in a junction box |
| Diagnostics | Only cable options E01, E02 and E03 are suitable for installation in hazardous locations, so the cable is part of the approval rather than an accessory to it. Cutting the moulded connector off to pull a cable through conduit discards the IP rating |
| Pressure range | Not applicable - a cable assembly with no process connection and no wetted parts |
| Variants | General purpose codes C01 to C17 across straight and angled connectors, terminated and unterminated ends, at 2, 5, 10, 20 and 50 m. Hazardous location versions E01 (5 m), E02 (20 m) and E03 (50 m), all M12 female angled to unterminated. Accessory number 01208-5000-0024 |
| Application | Connecting the Rosemount 1208 transmitter to a host or junction box over a moulded M12 cordset, in general purpose and hazardous location installations |
| Mounting | The M12 end is factory moulded and screws onto the transmitter, which is where the ingress rating comes from. The open end is terminated in a dry junction box or panel where a field-made connection is acceptable |
| Operating temperature (°C) | General purpose C-series rated IP66/IP68. The Ex E-series is rated IP68/IP69K, adding protection against high-pressure high-temperature jet washing |
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer