Overview
1208 flange options: DN50 to DN100 in 1.4404 stainless steel to EN1092-1 PN16, or PE100 plastic for non-pressurized installations only.
Key features
- Flange options for the Rosemount 1208: DN50, DN80 and DN100, in 1.4404 stainless steel to EN1092-1 PN16 or PE100 plastic to PN10/16, plus 2, 3 and 4 in Class 150 plastic
- The datasheet footnote decides the selection: PE100 flanges must be used ONLY in non-pressurized applications, and the stainless options are the pressurizable ones
- Plastic is the correct choice on open tanks and wet wells where it matches the plastic pipework and brings no dissimilar-metal couple, not a cheaper substitute
- The flange size is a beam decision, not a fit decision: all three take the same 1-1/2 in instrument thread, and a larger aperture is how a narrow-nozzle false echo is avoided
- Two flange standards coexist - EN1092-1 PN16 stainless and Class 150 plastic - so the mating flange standard decides which family is usable
Key specifications
- Accuracy
- No measurement function of its own, but the flange size sets the aperture the radar looks through: a narrow nozzle relative to the instrument produces a false echo close to the antenna, which is the practical reason to specify the larger size
- Output signal
- Not applicable - mechanical connection only
- Diagnostics
- Check the mating flange's standard and pressure class before choosing by DN size: EN1092-1 PN16 for the stainless family and Class 150 for the plastic PN2 to PN4 options, so a mismatch needs an adapter nobody planned for
- Pressure range
- Set by the flange family: the PE100 options are for non-pressurized applications only per the datasheet footnote, while the 1.4404 stainless options are dimensioned to EN1092-1 PN16
- Variants
- SG2/SG3/SG4 DN50/DN80/DN100 PN16 EN1092-1 in 1.4404. PG2/PG3/PG4 DN50/DN80/DN100 PN10/16 in PE100. PN2/PN3/PN4 2, 3 and 4 in Class 150 in PE100. Accessory numbers 01208-5000-0013/14/15 stainless, 01208-5000-0010/11/12 PE100 DN sizes, 01208-5000-0003/04/05 Class 150PE100
- Application
- Flanged mounting of the Rosemount 1208 transmitter on open tanks, sumps, wet wells, channel structures and process utility vessels, where the opening is flanged rather than threaded
Two materials with two very different promises
The 1208 flange options let the compact radar mount on a flanged opening instead of a thread. They come in two material families, and the difference between them is not cosmetic:
| Code | Flange | Material |
|---|---|---|
| SG2 | DN50 PN16, EN1092-1 | 1.4404 stainless steel |
| SG3 | DN80 PN16, EN1092-1 | 1.4404 stainless steel |
| SG4 | DN100 PN16, EN1092-1 | 1.4404 stainless steel |
| PG2 | DN50 PN10/16 | PE100 plastic |
| PG3 | DN80 PN10/16 | PE100 plastic |
| PG4 | DN100 PN10/16 | PE100 plastic |
| PN2 / PN3 / PN4 | 2 in, 3 in, 4 in Class 150 | PE100 plastic |
The datasheet carries a footnote against every PE100 option, and it is the one line that matters most on this page: the PE100 flanges must be used only in non-pressurized applications.
Why the plastic option exists at all
On water and wastewater installations a plastic flange is often the correct engineering choice, not a cheap one. A PE100 flange matches the plastic pipework it bolts to, brings no dissimilar-metal couple into the joint, does not corrode in a wet well, and costs less than stainless. On an open tank, a sump, a channel structure or a gravity-fed wet well — installations where the only pressure at the flange is a head of water measured in metres — that is exactly the right part.
What it is not is interchangeable with the stainless version. A PE100 flange on a closed, pressurized vessel is outside its stated application, and the failure mode is a joint that holds at commissioning and lets go later under a pressure cycle it was never designed for. The stainless options are the pressurizable ones; the plastic options are the non-pressurized ones, and the datasheet says so explicitly rather than leaving it to be inferred from a pressure class.
The flange size is a beam decision
All three sizes take the same 1½ in instrument connection, so the size is not about what fits the transmitter — it is about the opening the radar looks through.
A non-contacting radar needs a clear aperture between its antenna and the surface. A DN50 flange gives a smaller opening than a DN80, which in turn is smaller than a DN100, and a nozzle that is narrow relative to the instrument produces reflections from its own wall that appear in the measurement as a false echo close to the antenna. Specifying the larger flange is the standard way to avoid that — not because the instrument needs the space, but because the beam does.
Two flange standards in one table
The stainless family is dimensioned to EN1092-1 PN16; the plastic Class 150 options (PN2, PN3, PN4) serve installations dimensioned to the ANSI pattern. A plant's existing flange standard decides which of these is usable, and mixing a PN16 instrument flange into a Class 150 pipe spool creates a joint that needs an adapter nobody planned for. Check the mating flange's standard and pressure class before choosing by DN size alone.
The instrument still needs its thread
These flanges carry the 1208's 1½ in thread, so the transmitter screws into the flange rather than bolting directly. That has a practical consequence worth knowing: the thread length is part of the installed height, so it counts when the blocking distance and the mounting height are calculated.
Accessory part numbers
Where the flange is ordered as a separate accessory rather than as a model code, the numbers are 01208-5000-0010, -0011 and -0012 for the DN50, DN80 and DN100 PE100 versions, 01208-5000-0013, -0014 and -0015 for the DN50, DN80 and DN100 stainless versions, and 01208-5000-0003, -0004 and -0005 for the 2 in, 3 in and 4 in Class 150 plastic flanges.
Where it fits
Flanged mounting on open tanks, sumps, wet wells, channel structures and process utility vessels. Choose stainless where the vessel is pressurized or the flange is subject to process pressure, plastic where the installation is non-pressurized and the pipework is plastic, and choose the largest flange the installation will accept if the vessel has internals or a short nozzle — the beam, not the thread, is what the size is for.
Manufacturer reference: Rosemount 1208 Level and Flow Transmitter Product Data Sheet 00813-0200-7062 for flange codes, materials and the non-pressurized limitation on the PE100 options.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | No measurement function of its own, but the flange size sets the aperture the radar looks through: a narrow nozzle relative to the instrument produces a false echo close to the antenna, which is the practical reason to specify the larger size |
| Output signal | Not applicable - mechanical connection only |
| Diagnostics | Check the mating flange's standard and pressure class before choosing by DN size: EN1092-1 PN16 for the stainless family and Class 150 for the plastic PN2 to PN4 options, so a mismatch needs an adapter nobody planned for |
| Pressure range | Set by the flange family: the PE100 options are for non-pressurized applications only per the datasheet footnote, while the 1.4404 stainless options are dimensioned to EN1092-1 PN16 |
| Variants | SG2/SG3/SG4 DN50/DN80/DN100 PN16 EN1092-1 in 1.4404. PG2/PG3/PG4 DN50/DN80/DN100 PN10/16 in PE100. PN2/PN3/PN4 2, 3 and 4 in Class 150 in PE100. Accessory numbers 01208-5000-0013/14/15 stainless, 01208-5000-0010/11/12 PE100 DN sizes, 01208-5000-0003/04/05 Class 150PE100 |
| Application | Flanged mounting of the Rosemount 1208 transmitter on open tanks, sumps, wet wells, channel structures and process utility vessels, where the opening is flanged rather than threaded |
| Mounting | The flange carries the 1208's 1-1/2 in instrument thread, so the transmitter screws into the flange rather than bolting to it. Its thread length counts toward installed height when blocking distance and mounting height are calculated |
| Operating temperature (°C) | PE100 for water and wastewater installations matching plastic pipework, with no dissimilar-metal couple; 1.4404 stainless for pressurized and metallic installations |
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer