Rosemount 1208C Level and Flow Transmitter
Purchase options
From$344.27
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Zone 2 hazardous area 80 GHz radar for level and open channel flow: Ex ec increased safety, 4-20 mA HART Rev 7, +/-2 mm, submersible.
Key features
- Hazardous area version of the 1208 compact radar: 80 GHz level and open channel flow measurement in Zone 2 / Division 2
- The EX option is Increased Safety (Ex ec), Zone 2 and Division 2 per ATEX, IECEx, USA and Canada - it is the ONLY hazardous area option, so there is no Zone 1 variant of this instrument
- Increased safety means no intrinsic safety barrier, no entity parameters and no loop energy arithmetic, which is the honest reason to buy it where Zone 2 is what the plant actually has
- Integrates over 4-20 mA with HART Revision 7 rather than IO-Link, so a skid built around an IO-Link master does not simply accept it in place of the 1208A
- Selecting the radio spectrum for the country of installation is a compliance requirement: operating without it may violate that country's radio approval
- +/-2 mm accuracy excluding installation-dependent offset, Smart Echo Supervision, submersible housing, and the 1208 family's flanges and brackets
Key specifications
- Accuracy
- +/-0.08 in (+/-2 mm) under reference conditions per IEC 60770-1, excluding installation-dependent offset. Repeatability +/-1 mm, ambient temperature effect +/-1 mm per 10 K, one update per second
- Output signal
- 4-20 mA with HART Revision 7, with Bluetooth models for local configuration and maintenance. Pairs with the Rosemount 3490 Controller for local pump or dosing control on 4-20 mA and HART devices
- Diagnostics
- Smart Echo Supervision keeps the reading reliable in small tanks and fast-filling vessels. Two configuration obligations: select the radio spectrum for the country of installation, since operating without it may violate that country's radio approval, and confirm the area classification is Zone 2 before selecting this instrument
- Pressure range
- Not a pressure instrument. Connections are a 1-1/2 in thread, DN50 and DN80 flanges in 1.4404, plus standard and extendable 316L mounting brackets for pipe, ceiling and wall
- Variants
- The EX hazardous locations option is Increased Safety, Zone 2 / Division 2, certified to ATEX, IECEx, USA and Canada, available with cable options E01, E02 and E03. It is the only hazardous area certification option, so there is no Zone 1 variant
- Application
- Level and open channel flow in Zone 2 or Division 2 areas: sumps and wet wells with classified atmospheres, chemical dosing and storage areas, and tank farms where the area classification permits increased safety
The C is not a badge: it is one certification, and it is Zone 2
The Rosemount 1208C is the hazardous-area version of the 1208 compact radar — the same 80 GHz measurement of level and open channel flow, in a housing described as compact, submersible and suitable for hazardous locations, with 4–20 mA HART Revision 7 and Bluetooth models. The specification that decides whether it can be used is the certification code, and the datasheet is precise about it.
What the certification option actually says
The hazardous locations option EX is listed as Increased Safety, Zone 2 / Division 2, certified to ATEX, IECEx, USA and Canada standards, and available with cable options E01, E02 and E03. It is the only hazardous-area certification option on the datasheet.
That single line has a hard consequence: there is no Zone 1 variant of this instrument. A project that specifies the 1208C because it needs “the hazardous area version”, and then installs it in a Zone 1 area, has bought an instrument whose certification does not cover the location — and the mistake survives every review that only reads the phrase “hazardous locations” on the summary page.
Why Zone 2 and increased safety are a coherent pair
Zone classification describes how likely a flammable atmosphere is. Zone 2 means it is present only in abnormal conditions and only briefly. Increased safety (Ex ec) is the protection concept that matches it: the enclosure is constructed so that it cannot produce sparks or hot surfaces in normal operation, which is exactly the risk that matters when the atmosphere is normally absent.
The practical benefit is what is not needed. There is no intrinsic safety barrier to specify, no entity parameters to check against a barrier's output, and no loop-length arithmetic to do against a limited energy budget. On a Zone 2 application where increased safety is accepted, that is the simplest certified path available — and it is the honest reason to buy this instead of an intrinsically safe instrument rated for a zone the plant does not have.
4–20 mA HART, not IO-Link
The 1208C integrates over 4–20 mA with HART Revision 7. That is a real difference from the general-purpose 1208A, which is a three-wire IO-Link device — so a skid designed around an IO-Link master does not simply accept this transmitter in place of its sibling. The analog loop with HART overlay is the older and more universal integration, and on an existing plant that is usually the point: it drops into a loop that already exists.
Where local control is wanted, the transmitter pairs with the Rosemount 3490 Controller, which provides control functionality for 4–20 mA and HART compatible devices — a pump-up/pump-down or dosing application can be closed locally rather than in a PLC.
One configuration step that is a legal obligation
The datasheet carries a footnote worth reading twice: radar performance may be affected if the instrument is configured for certain local radio spectrum regulations, and operating the device without selecting the relevant radio spectrum may constitute a violation of the radio approvals of the respective country.
That is not a performance note; it is a compliance requirement. An 80 GHz radar is a radio transmitter, each country approves particular spectrum use, and the instrument has to be told which regime applies where it is installed. A transmitter left on a default setting in a country whose approval differs is out of compliance even though it measures perfectly — and nothing on the display says so.
The measurement it inherits
Accuracy is ±0.08 in (±2 mm) under reference conditions per IEC 60770-1, excluding installation-dependent offset, with repeatability of ±1 mm and an ambient temperature effect of ±1 mm per 10 K, at one update per second. The measurement chain uses Smart Echo Supervision to keep the reading reliable in small tanks and fast-filling vessels, and the housing is submersible for the sumps, wet wells and open channels where these instruments usually live.
Open channel flow works the same way as on the rest of the family: the instrument measures level, and volume flow is calculated from the channel structure's head–flow relationship. The channel, not the radar, is the limiting error in a flow installation.
Mechanically it takes the 1208 family's connections and accessories — 1½ in thread, DN50 and DN80 flanges in 1.4404, and the standard or extendable 316L mounting brackets for pipe, ceiling and wall.
Where it fits
Level and open channel flow in Zone 2 or Division 2 areas: sumps and wet wells in wastewater plants with classified atmospheres, chemical dosing and storage areas, and tank farms where the classification permits increased safety. Confirm the zone with the area classification drawing before selecting it, choose the radio spectrum for the country of installation, and note that a Zone 1 location needs a different instrument rather than a different option code.
Manufacturer reference: Rosemount 1208C Level and Flow Transmitter Product Data Sheet for performance, the EX certification option, HART integration and the radio spectrum requirement, with the separate Product Certifications document for approval details.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | +/-0.08 in (+/-2 mm) under reference conditions per IEC 60770-1, excluding installation-dependent offset. Repeatability +/-1 mm, ambient temperature effect +/-1 mm per 10 K, one update per second |
| Output signal | 4-20 mA with HART Revision 7, with Bluetooth models for local configuration and maintenance. Pairs with the Rosemount 3490 Controller for local pump or dosing control on 4-20 mA and HART devices |
| Diagnostics | Smart Echo Supervision keeps the reading reliable in small tanks and fast-filling vessels. Two configuration obligations: select the radio spectrum for the country of installation, since operating without it may violate that country's radio approval, and confirm the area classification is Zone 2 before selecting this instrument |
| Pressure range | Not a pressure instrument. Connections are a 1-1/2 in thread, DN50 and DN80 flanges in 1.4404, plus standard and extendable 316L mounting brackets for pipe, ceiling and wall |
| Variants | The EX hazardous locations option is Increased Safety, Zone 2 / Division 2, certified to ATEX, IECEx, USA and Canada, available with cable options E01, E02 and E03. It is the only hazardous area certification option, so there is no Zone 1 variant |
| Application | Level and open channel flow in Zone 2 or Division 2 areas: sumps and wet wells with classified atmospheres, chemical dosing and storage areas, and tank farms where the area classification permits increased safety |
| Mounting | Same mechanical family as the 1208: thread, DN50 or DN80 flange, or the BZS standard and BZE extendable 316L brackets. Submersible construction suits sumps, wet wells and open channels |
| Operating temperature (°C) | Housing described as compact and robust, able to withstand outdoor conditions and submersible, suitable for hazardous locations. Radio performance may be affected if the unit is configured for certain local radio spectrum regulations |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer