Rosemount 1408H Non-Contacting Radar Level Transmitter
Purchase options
From$540.72
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
80 GHz hygienic non-contacting radar for small tanks: no probe in the product, 3-A and EHEDG by adapter, IP69/IP6K9K washdown, 4-20 mA and IO-Link.
Key features
- Compact 80 GHz FMCW non-contacting radar level transmitter for hygienic tanks, certified to 3-A and EHEDG with wetted parts complying with FDA and EC 1935/2004
- Nothing enters the product: no probe rod, no tines, no cavity - the only wetted surfaces are the antenna face and the process adapter, so there is nothing to clean around and nothing to build up on
- IP69 and IP6K9K: rated for CIP and SIP processes as well as external washdown
- Certifications depend on the adapter: the 1-1/2 in Tri-Clamp CA adapter lists 3-A and FDA only, while the 2 in C2 and VARIVENT Type F adapters add EHEDG
- 80 GHz gives a narrow beam for a compact antenna, which is what lets it sit in a short nozzle or near a wall in a small tank with an agitator
- 4-20 mA alongside IO-Link with digital switch outputs, so the same part number serves an analog replacement and a digital skid
Key specifications
- Accuracy
- 80 GHz FMCW with smart algorithms aimed at small tanks and fast-filling vessels, so the measurement holds while the surface is moving rather than requiring a still surface
- Output signal
- 4-20 mA and IO-Link, with digital switch outputs enabled through the IO-Link connection. The same part number serves an analog loop replacement or a digital skid with no analog path
- Diagnostics
- Non-contacting means the only wetted surfaces are the antenna face and the adapter - no probe rod to clean around and nothing in the product to build up on, which is the maintenance this design avoids. Certifications belong to the assembly, so the adapter choice decides whether EHEDG conformance is included
- Pressure range
- Set by the hygienic adapter and seal selected. The instrument is a compact top-mounted radar with a G1 process connection that accepts a suite of hygienic adapters
- Variants
- Hygienic adapters on the G1 connection: CA 1-1/2 in Tri-Clamp (ISO 2852 / DIN 32676) with 3-A and FDA; C2 2 in Tri-Clamp with 3-A, EHEDG and FDA; VF VARIVENT Type F with 3-A, EHEDG and FDA. The adapter ships with an EPDM O-ring, with other materials available as accessories
- Application
- Continuous level in dairy, beverage, brewing, food and pharmaceutical vessels, particularly small tanks, vessels with agitators, and lines cleaned on a schedule
Non-contacting means the only thing in the product is the seal face
The Rosemount 1408H is a compact 80 GHz FMCW radar level transmitter for hygienic tanks: 3-A and EHEDG certified, with process wetted parts complying with FDA and EC 1935/2004, rated IP69 and IP6K9K for CIP, SIP and external washdown, and offering 4–20 mA alongside IO-Link.
What is not in the tank
Every other level technology puts something into the product. A guided wave radar needs a rod down the middle of the vessel, a vibrating fork needs tines at the switching point, a diaphragm seal needs a cavity and a thin barrier. A non-contacting radar measures from above, and the only wetted surface is the antenna face and the process adapter.
On a hygienic process that difference is not a detail. A probe rod in a dairy or brewery vessel is a surface that CIP has to reach all the way around, and product that dries on a rod between washes is exactly what a swab test finds. Product that crystallises or coats on a probe changes the measurement as well. A radar has neither problem: there is nothing in the volume to clean around and nothing to build up on. That is why the datasheet calls it ideal for the hygienic industry on the grounds of being maintenance-free — the maintenance it avoids is the cleaning and the re-calibration after cleaning.
80 GHz, and why the frequency is the small-tank answer
The 80 GHz carrier is what makes a compact radar usable in a small hygienic vessel. Higher frequency means a narrower beam for a given antenna size, and a narrow beam is what allows the instrument to sit in a short nozzle or close to the tank wall without the wall echo competing with the product echo. On a small tank with an agitator, the beam has to miss the blades on the way down and miss the wall on the way back — a wide beam sees both, and the reflection from a moving agitator is the kind of false echo that a level reading cannot distinguish from a real surface.
The transmitter uses FMCW with algorithms aimed specifically at small tanks and fast-filling vessels. Fast filling matters because the surface is moving while the measurement is taken; a radar that needs a still surface is a radar that reports the level of a moment ago.
The adapter decides which certificate you actually get
This is the detail worth reading twice. The instrument is described as hygienically certified to 3-A and EHEDG, and the G1 process connection takes a range of hygienic adapters — but they do not all carry the same certifications:
| Adapter | Certifications listed |
|---|---|
| CA — 1½ in Tri-Clamp (ISO 2852 / DIN 32676) | 3-A, FDA |
| C2 — 2 in Tri-Clamp (ISO 2852 / DIN 32676) | 3-A, EHEDG, FDA |
| VF — VARIVENT Type F | 3-A, EHEDG, FDA |
So a specification that requires EHEDG conformance and then selects the 1½ inch Tri-Clamp adapter has bought an instrument whose certificate does not cover the joint it is installed with. The transmitter's headline claim is about the design; the conformance that matters at an audit belongs to the assembly, and the adapter is part of the assembly. The same applies to the O-ring: the adapter arrives with an EPDM ring and others are available as accessories, which is another material decision in the wetted path.
Two outputs, two eras of integration
The instrument provides 4–20 mA and IO-Link, with digital switch outputs enabled through the IO-Link connection. That combination is deliberate: a plant replacing an analog level transmitter wires the 4–20 mA loop and changes nothing else, while a skid built around an IO-Link master gets the measurement, the switch states and the parameters over one digital cable with no analog signal path at all.
The practical consequence is that the same part number serves a brownfield replacement and a new hygienic skid. And on the IO-Link side the value is not just the wiring: parameters and events travel with the process data, so a device can report that it needs attention rather than only reporting a level.
Where it fits
Continuous level in dairy, beverage, brewing, food and pharmaceutical vessels — particularly small tanks, vessels with agitators, and lines that are cleaned on a schedule. Choose the adapter for the certification and the connection standard the plant already uses rather than for what fits, keep the O-ring material in the specification, and mount the instrument where the narrow beam has a clear path to the surface.
Manufacturer reference: Rosemount 1408H Non-Contacting Radar Level Transmitter Product Data Sheet 00813-0100-4480 for measurement specification, hygienic certifications by adapter, washdown ratings and IO-Link integration.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | 80 GHz FMCW with smart algorithms aimed at small tanks and fast-filling vessels, so the measurement holds while the surface is moving rather than requiring a still surface |
| Output signal | 4-20 mA and IO-Link, with digital switch outputs enabled through the IO-Link connection. The same part number serves an analog loop replacement or a digital skid with no analog path |
| Diagnostics | Non-contacting means the only wetted surfaces are the antenna face and the adapter - no probe rod to clean around and nothing in the product to build up on, which is the maintenance this design avoids. Certifications belong to the assembly, so the adapter choice decides whether EHEDG conformance is included |
| Pressure range | Set by the hygienic adapter and seal selected. The instrument is a compact top-mounted radar with a G1 process connection that accepts a suite of hygienic adapters |
| Variants | Hygienic adapters on the G1 connection: CA 1-1/2 in Tri-Clamp (ISO 2852 / DIN 32676) with 3-A and FDA; C2 2 in Tri-Clamp with 3-A, EHEDG and FDA; VF VARIVENT Type F with 3-A, EHEDG and FDA. The adapter ships with an EPDM O-ring, with other materials available as accessories |
| Application | Continuous level in dairy, beverage, brewing, food and pharmaceutical vessels, particularly small tanks, vessels with agitators, and lines cleaned on a schedule |
| Mounting | Top-mounted in a short nozzle or directly on the vessel. The narrow 80 GHz beam allows mounting close to a wall or with an agitator in the vessel, where a wider beam would see the wall or the moving blades |
| Operating temperature (°C) | Rated IP69 and IP6K9K, designed to withstand CIP and SIP processes as well as external washdown, with wetted parts complying with FDA and EC 1935/2004 |