Rosemount 1496 Orifice Flange Union
Purchase options
From$231.49
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Orifice flange union for 1495 plates with jackscrews for plate changeout: ASME B16.36/B16.5 classes 300 to 2500, temperature set by the gasket.
Key features
- Orifice flange union that holds a 1495 plate between flanges and carries the pressure taps
- Jackscrews and jackscrew nuts spread the union so the plate can be changed without disturbing the pipe
- Flange types WN, SO, TH and RJ per ASME B16.36 and B16.5, or DN per EN-1092-1; classes 300 through 2500
- Temperature limits come from the gasket, not the flange: compressed sheet -100 to 250 F, PTFE spiral wound to 250 F, graphite spiral wound to 900 F, high temperature filler to 1250 F
- Maximum working pressure per ASME B16.36 and B16.5, or EN-1092-1 for DN flanges
- Ordered as a set with the 1495 plate: line size, class, facing, tap arrangement, bore, gasket and bolting
Key specifications
- Accuracy
- Not a measuring element itself; it positions and seals the plate, so the accuracy of the installation depends on the plate bore, the tap arrangement and the straight run rather than on the union
- Output signal
- None - the union carries the pressure taps that feed the DP transmitter; the plate generates the differential
- Diagnostics
- Ordered as a set with the plate: line size, flange class, facing, tap arrangement, plate bore, gasket and bolting; the line tag on the plate is what keeps the correct bore in the correct line after a rebuild
- Pressure range
- Maximum working pressure per ASME B16.36 and B16.5 for WN, SO, TH and RJ flange types, or EN-1092-1 for DN flanges; flange classes 300 through 2500 are covered in the published gasket table
- Variants
- Flange types WN, SO, TH and RJ to ASME B16.36/B16.5, or DN to EN-1092-1, in classes 300 to 2500, with gasket and bolting options selected per service
- Application
- Holding a 1495 orifice plate between flanges with pressure taps, in steam, gas and liquid DP flow installations where the plate has to be inspectable and replaceable
The flanges that hold the plate, and let you change it without cutting pipe
The Rosemount 1496 is the orifice flange union that pairs with a 1495 plate: two flanges with pressure taps, through-bolts, and jackscrews — the screws that spread the union so the plate can be pulled and replaced without disturbing the pipe. It is the half of a DP flow installation that is welded into the line, and the half that decides what the installation can be maintained at.
The jackscrews are the point
A plate changeout on a flange union without jackscrews means loosening bolts and hoping the joint opens far enough — with the line drained, the gasket replaced, and the flange faces re-aligned afterwards. The 1496 carries jackscrews and jackscrew nuts so the union is spread deliberately: turn clockwise to open, counter-clockwise to release, slide the paddle out, slot the new plate in, close. That is a planned maintenance task with a torque wrench instead of a pipefitting job, and it is why the plate's handle matters — the handle is what the fitter pulls.
Rating lives on the flange, temperature lives on the gasket
The flanges follow ASME B16.36 and B16.5 for the WN, SO, TH and RJ types, or EN-1092-1 for DN flanges, and maximum working pressure comes from those standards. Temperature does not: it comes from the gasket that is fitted. For raised face flanges the published limits are compressed sheet -100 to 250 °F (-73 to 121 °C), PTFE-filled spiral wound -350 to 250 °F (-212 to 121 °C), graphite spiral wound -350 to 900 °F (-212 to 482 °C), and the high temperature filler option to 1250 °F (677 °C) subject to the flange material. A class 1500 union with a compressed sheet gasket is a 250 °F installation, whatever the flange class says.
Classes and sizes
The gasket table covers Class 300 and 600 through 2500, which is the range these unions are actually ordered in for steam and process service. Sizes follow the line the plate is going into, and the plate is ordered to the same flange class and bore — a mismatch between the union's class and the plate's size stamp is the kind of error that is only found when the joint will not close.
Ordering it as a set
The union and the plate are specified together: line size, flange class, facing (raised face or ring joint), tap arrangement, plate bore, gasket and bolting. That is why the plate carries a line tag and the union is normally tagged to match — in a plant with a rack of spare plates, the tag is what keeps the correct bore in the correct line after a maintenance rebuild.
Where it fits
Steam, gas and liquid DP flow installations in any line large enough to justify a flange union rather than an integral orifice body: boiler feedwater, steam headers, fuel gas, and process lines where the plate has to be inspectable. Where the line is small and the plate is integral to the transmitter, the flange union does not apply.
Manufacturer reference: Rosemount 1495 Orifice Plate and 1496 Orifice Flange Union Reference Manual 00809-0100-4792, and the 1495/1496 specifications in the Rosemount DP Flow Meters Product Data Sheet.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not a measuring element itself; it positions and seals the plate, so the accuracy of the installation depends on the plate bore, the tap arrangement and the straight run rather than on the union |
| Output signal | None - the union carries the pressure taps that feed the DP transmitter; the plate generates the differential |
| Diagnostics | Ordered as a set with the plate: line size, flange class, facing, tap arrangement, plate bore, gasket and bolting; the line tag on the plate is what keeps the correct bore in the correct line after a rebuild |
| Pressure range | Maximum working pressure per ASME B16.36 and B16.5 for WN, SO, TH and RJ flange types, or EN-1092-1 for DN flanges; flange classes 300 through 2500 are covered in the published gasket table |
| Variants | Flange types WN, SO, TH and RJ to ASME B16.36/B16.5, or DN to EN-1092-1, in classes 300 to 2500, with gasket and bolting options selected per service |
| Application | Holding a 1495 orifice plate between flanges with pressure taps, in steam, gas and liquid DP flow installations where the plate has to be inspectable and replaceable |
| Mounting | Jackscrews and jackscrew nuts spread the union so the plate can be removed and replaced; turn clockwise to spread and counter-clockwise to release, with the line drained and the gasket replaced |
| Operating temperature (°C) | Set by the gasket, not the flange class: compressed sheet -100 to 250 F (-73 to 121 C), PTFE-filled spiral wound -350 to 250 F, graphite spiral wound -350 to 900 F (-212 to 482 C), high temperature filler to 1250 F (677 C) subject to flange material |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer