Conditioning orifice plate with four bore holes that conditions and measures in one disc, needing only two pipe diameters of straight run; 2 to 24 in line sizes.
Key features
- Conditioning orifice plate: flow conditioner and orifice in one primary element
- Requires only 2 pipe diameters upstream and downstream of most flow disturbances
- Line sizes 2 to 24 in (50 to 600 mm); beta ratios 0.20, 0.40, 0.50 and 0.65
- Discharge coefficient uncertainty from +/-0.50% with the 10-point WD verification
- Temperature range -196 to 649 C; differential pressure to 800 inH2O up to 427 C
- 316/316L stainless steel standard, Alloy C-276 and Alloy 400 options, NACE MR0175
Key specifications
- Accuracy
- Discharge coefficient uncertainty +/-0.50% at beta 0.20 and 0.40 and +/-1.00% at beta 0.50 and 0.65 with 10-point calibration (option WD); +/-0.50% to +/-1.50% with standard calibration; add 0.5% below a pipe Reynolds number of 10,000
- Pressure rating
- Maximum working pressure per flange rating to ANSI B16.5 and DIN EN 1092-1, Class 150 through Class 2500, raised face or ring joint
- Certifications
- Material certification to ISO 10474 3.1-B and EN 10204 3.1 available; optional full 10-point discharge coefficient verification
- Measurement range
- Line sizes 2 to 24 in (50 to 600 mm); beta ratios 0.20, 0.40, 0.50 and 0.65; turbulent flow with pipe Reynolds number above 5,000
- Application
- Conditioning orifice plate for differential pressure flow measurement of liquid, gas or steam, combining flow conditioning and the primary element in one disc
- Mounting
- Paddle (P) or universal (U) plate types; requires only 2 diameters of straight run upstream and downstream of most disturbances; pressure taps centred between two of the four bore holes and 90 degrees to the last upstream elbow when under 6 diameters or at 0.65 beta
A flow conditioner and an orifice plate in the same disc
The Rosemount 1595 is a conditioning orifice plate: four bore holes arranged in a square pattern, machined into the same plate that does the measuring. The conditioning and the measurement are one part, which is why it needs only two diameters of straight pipe upstream and two downstream.
Why the straight run matters
A conventional orifice plate assumes the flow arriving at it is a clean, symmetrical profile. In a real plant the plate often sits downstream of an elbow, a valve or a reducer, and the profile is skewed — which biases the measurement in a way no amount of transmitter accuracy corrects. The usual answer is a long straight run, which is pipe, steel, space and money. The 1595's four-hole pattern forces the profile to mix across the plate itself, so the installation fits where a standard plate would need metres of upstream pipe.
Uncertainty, stated honestly
Discharge coefficient uncertainty is ±0.50% at beta 0.20 and 0.40, and ±1.00% at beta 0.50 and 0.65, when ordered with the full 10-point discharge coefficient verification (option WD). With standard calibration the figures are ±0.50% to ±1.50% depending on beta. Below a pipe Reynolds number of 10,000, add 0.5% — a caveat worth remembering on small lines and viscous liquids, where it is usually the dominant term.
Range and envelope
Line sizes from 2 to 24 in (50 to 600 mm), with beta ratios of 0.20, 0.40, 0.50 and 0.65. Temperature range is -196 to 649 °C. Differential pressure capability depends on temperature: up to 800 inH2O to 427 °C, and 400 inH2O above that, because material strength and thermal expansion change what the plate can take. Maximum working pressure follows the flange rating, ANSI B16.5 or DIN EN 1092-1, from Class 150 to Class 2500.
Materials and options
Plates are 316/316L stainless steel as standard, with Alloy C-276 and Alloy 400 available, and materials comply with NACE MR0175/ISO for sour oil field service. Paddle (P) and universal (U) plate types cover standard orifice flanges and the wider version; thickness steps from 0.125 in on 2 to 4 in lines up to 0.500 in on 24 in lines. Material certification to ISO 10474 3.1-B / EN 10204 3.1 is available, along with the discharge coefficient verification.
Installing it correctly
Pressure taps are centred between any two of the four bore holes, and must sit at 90 degrees to the plane of the last upstream elbow when there is less than six diameters of upstream pipe, or when a 0.65 beta plate is used. Those two rules are where most of the field errors happen, and neither is optional for the uncertainty figures above to mean anything.
Manufacturer reference: Rosemount 1595 Conditioning Orifice Plate, Rosemount DP Flow Product Data Sheet, March 2015.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Discharge coefficient uncertainty +/-0.50% at beta 0.20 and 0.40 and +/-1.00% at beta 0.50 and 0.65 with 10-point calibration (option WD); +/-0.50% to +/-1.50% with standard calibration; add 0.5% below a pipe Reynolds number of 10,000 |
| Pressure rating | Maximum working pressure per flange rating to ANSI B16.5 and DIN EN 1092-1, Class 150 through Class 2500, raised face or ring joint |
| Certifications | Material certification to ISO 10474 3.1-B and EN 10204 3.1 available; optional full 10-point discharge coefficient verification |
| Measurement range | Line sizes 2 to 24 in (50 to 600 mm); beta ratios 0.20, 0.40, 0.50 and 0.65; turbulent flow with pipe Reynolds number above 5,000 |
| Application | Conditioning orifice plate for differential pressure flow measurement of liquid, gas or steam, combining flow conditioning and the primary element in one disc |
| Mounting | Paddle (P) or universal (U) plate types; requires only 2 diameters of straight run upstream and downstream of most disturbances; pressure taps centred between two of the four bore holes and 90 degrees to the last upstream elbow when under 6 diameters or at 0.65 beta |
| Dimensions | Plate thickness 0.125 in for 2 to 4 in lines, 0.250 in for 6 to 12 in, 0.375 in for 14 to 20 in and 0.500 in for 24 in lines (paddle plate type) |
| Material of construction | 316/316L stainless steel standard; Alloy C-276 and Alloy 400 options; materials comply with NACE MR0175/ISO 15156 for sour oil field service |
| Operating temperature (°C) | -196 to 649 °C (-320 to 1200 °F); differential pressure up to 800 inH2O to 427 °C, and up to 400 inH2O from 427 to 649 °C |