Skip to main content
Sold and shipped by Sproh

Rosemount 1595 Conditioning Orifice Plate

Part number1595ManufacturerEmerson

Purchase options

From$275.88

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Conditioning orifice plate with four bore holes that conditions and measures in one disc, needing only two pipe diameters of straight run; 2 to 24 in line sizes.

Key features

  • Conditioning orifice plate: flow conditioner and orifice in one primary element
  • Requires only 2 pipe diameters upstream and downstream of most flow disturbances
  • Line sizes 2 to 24 in (50 to 600 mm); beta ratios 0.20, 0.40, 0.50 and 0.65
  • Discharge coefficient uncertainty from +/-0.50% with the 10-point WD verification
  • Temperature range -196 to 649 C; differential pressure to 800 inH2O up to 427 C
  • 316/316L stainless steel standard, Alloy C-276 and Alloy 400 options, NACE MR0175

Key specifications

Accuracy
Discharge coefficient uncertainty +/-0.50% at beta 0.20 and 0.40 and +/-1.00% at beta 0.50 and 0.65 with 10-point calibration (option WD); +/-0.50% to +/-1.50% with standard calibration; add 0.5% below a pipe Reynolds number of 10,000
Pressure rating
Maximum working pressure per flange rating to ANSI B16.5 and DIN EN 1092-1, Class 150 through Class 2500, raised face or ring joint
Certifications
Material certification to ISO 10474 3.1-B and EN 10204 3.1 available; optional full 10-point discharge coefficient verification
Measurement range
Line sizes 2 to 24 in (50 to 600 mm); beta ratios 0.20, 0.40, 0.50 and 0.65; turbulent flow with pipe Reynolds number above 5,000
Application
Conditioning orifice plate for differential pressure flow measurement of liquid, gas or steam, combining flow conditioning and the primary element in one disc
Mounting
Paddle (P) or universal (U) plate types; requires only 2 diameters of straight run upstream and downstream of most disturbances; pressure taps centred between two of the four bore holes and 90 degrees to the last upstream elbow when under 6 diameters or at 0.65 beta
See all specifications