Rosemount 2 1/2x5 Thrust Type Power Positioner
Purchase options
From$860.91
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Swivel mounted pneumatic thrust type power positioner: 2-1/2 x 5 cylinder, 500 lb stall thrust, ±1% accuracy, internal air lock, 45 to 120 psig air.
Key features
- Swivel mounted pneumatic thrust type power positioner, 2-1/2 x 5 cylinder, clevis output
- Stall thrust 500 lb (228 kg); maximum friction load 125 lb (57 kg); maximum weight load 175 lb (79 kg)
- Accuracy ±1% of full scale with ±0.8% hysteresis; full stroke 2 seconds or less
- Internal air locking system holds the last position on loss of air supply
- Input 3-15, 3-27, 0-30 or 0-60 psig and 4-20 mA; air supply 45 to 120 psig at 0.5 scfm
- Air filter-regulator 4505C21G03 required but not included; one filter serves up to 12 positioners
Key specifications
- Accuracy
- Accuracy +/-1% of full scale with hysteresis +/-0.8% of full scale; positioning accuracy 1% on the 3-27 psi control signal; full stroke time 2 seconds or less
- Output signal
- Stall thrust 500 lb (228 kg) over a 5 in. stroke through an integral clevis; maximum friction load 125 lb (57 kg) and maximum allowable weight load 175 lb (79 kg)
- Diagnostics
- Internal air locking system holds the last position on loss of air supply; the air filter-regulator (style 4505C21G03) is required but not included and serves up to 12 positioners, with two in parallel for twelve
- Pressure range
- Air supply 45 to 120 psig (310 to 827 kPa gauge) with 100 psig recommended; air consumption 0.5 scfm of free air
- Variants
- Input signal 3-15, 3-27, 0-30 or 0-60 psig and 4-20 mA; options include a fail safe package on loss of power air, I/P signal converter, dual limit switches, pivot base and anchor pivot pin for CE installations
- Application
- Swivel mounted linear thrust actuation of small-to-medium lever-operated dampers: burner air, flue gas recirculation and trim blades on packaged boilers
The small thrust drive that still behaves like an instrument
The Rosemount 2-1/2 x 5 thrust type power positioner is the smallest pneumatic damper drive in the Hagan family: a 2-1/2 inch cylinder with a 5 inch stroke, 500 lb of stall thrust, and a swivel mount that lets it follow a lever arm without side-loading its own rod. It is the drive for the dampers that are small but still have to be positioned accurately — burner air, flue gas recirculation, and the trim blades on a packaged boiler.
"Positioner accuracy at this size
Accuracy is ±1 percent of full scale with hysteresis of ±0.8 percent, and positioning accuracy is 1 percent on the 3-27 psi control signal. Those numbers are what separate a power positioner from a plain spring-return cylinder: the internal feedback loop corrects for friction and for the spring's own characteristic, so a 5 psi signal change produces the same blade movement at the start of the stroke as at the end.
"The internal air lock
This model carries an internal air locking system: on loss of air supply the drive holds its last position rather than drifting to one end of the stroke. On a combustion air damper that is a deliberate choice and it has to match the burner management philosophy — holding position keeps the air/fuel relationship where it was, while a spring return to closed would starve the flame and one to open would over-air it. The fail-safe option is available separately when the application calls for a defined end position instead.
"Signal and air
The positioner accepts 3-15, 3-27, 0-30 or 0-60 psig, and 4-20 mA — the widest signal list in the family, which is why this model turns up on retrofit work where the existing controller is pneumatic and the new one is not. Air supply is 45 to 120 psig with 100 psig recommended, at 0.5 scfm of free air. Temperature limits are 0 to 170 °F (-18 to 77 °C).
"Load limits
Stall thrust is 500 lb (228 kg), maximum friction load 125 lb (57 kg) and maximum allowable weight load 175 lb (79 kg). The friction figure is a quarter of the stall thrust, which is normal for this family: a stiff linkage consumes the margin long before the cylinder runs out of force, and the drive's accuracy degrades with it.
"What is included, and what is not
The clevis, clevis pin and retaining rings are integral and included, and the instruction manual comes with the unit. The air filter-regulator is not included — Emerson specifies style 4505C21G03 and says to order it with the positioner; one filter serves up to twelve units, with two in parallel when twelve are installed. Options are a fail-safe package, an I/P converter, dual limit switches, a pivot base, and an anchor pivot pin for CE installations.
"Where it fits
Small packaged boilers, burner air and FGR dampers, and any lever-operated damper where thrust is a few hundred pounds and the position still has to repeat to one percent. It is the direct-mounted counterpart to the floor-mounted drives in the same family.
"Manufacturer reference: Rosemount Analytical Damper Drives Product Data Sheet, 2-1/2 x 5 thrust type swivel mounted section, and instruction manual IB 102-202N.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Accuracy +/-1% of full scale with hysteresis +/-0.8% of full scale; positioning accuracy 1% on the 3-27 psi control signal; full stroke time 2 seconds or less |
| Output signal | Stall thrust 500 lb (228 kg) over a 5 in. stroke through an integral clevis; maximum friction load 125 lb (57 kg) and maximum allowable weight load 175 lb (79 kg) |
| Diagnostics | Internal air locking system holds the last position on loss of air supply; the air filter-regulator (style 4505C21G03) is required but not included and serves up to 12 positioners, with two in parallel for twelve |
| Pressure range | Air supply 45 to 120 psig (310 to 827 kPa gauge) with 100 psig recommended; air consumption 0.5 scfm of free air |
| Variants | Input signal 3-15, 3-27, 0-30 or 0-60 psig and 4-20 mA; options include a fail safe package on loss of power air, I/P signal converter, dual limit switches, pivot base and anchor pivot pin for CE installations |
| Application | Swivel mounted linear thrust actuation of small-to-medium lever-operated dampers: burner air, flue gas recirculation and trim blades on packaged boilers |
| Mounting | Swivel mounted so the cylinder follows the lever arm it drives; clevis, clevis pin and retaining rings integral and included; instruction manual IB 102-202N supplied |
| Operating temperature (°C) | 0 to 170 F (-18 to 77 C) |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer