Overview
Coplanar differential and gauge transmitter for pressure, level and flow. Differential spans start at 0.5 inH2O and reach 2000 psi, reference accuracy is 0.075 % of span with a 0.05 % high-accuracy option, and output is 4-20 mA HART or 1-5 V low power.
Key features
- Coplanar body that takes a flange, manifold or remote seal directly
- Differential spans from 0.5 inH2O to 2000 psi; gauge to 2000 psi
- 0.075 % of span reference accuracy, 0.05 % high-accuracy option
- 100:1 rangedown, so one spare covers several installed spans
- 4-20 mA with selectable HART 5/7, or 1-5 V low-power output
- SIL 2/3 (IEC 61508) with explosion-proof and intrinsically safe options
Key specifications
- Measurement principle
- Coplanar piezoresistive sensor for differential and gauge pressure
- Accuracy
- 0.075 % of span reference accuracy; 0.05 % high-accuracy option
- Process temperature
- -46 to 121 C (-50 to 250 F) depending on fill fluid
- Pressure rating
- Up to 2000 psi (137.9 bar) static on the highest differential code
- Process connection
- Coplanar flange with 1/4-18 NPT; manifold or diaphragm seal mounts directly
- Enclosure rating
- NEMA 4X / IP65, IP66, IP67
What this transmitter is
The 2051C is the Coplanar transmitter in Emerson's 2051 line. The body presents two process ports on a flat face, so a flange, a three- or five-valve manifold or a diaphragm seal bolts straight on, and the same instrument serves pressure, level and flow duties.
Ranges
- Differential codes start at -25 to 25 inH2O and reach -2000 to 2000 psi.
- Gauge codes read -14.2 to 2000 psi on the highest range.
- Reference accuracy 0.075 % of span, with a 0.05 % high-accuracy option.
Turndown and stability
Rangedown reaches 100:1, so a single spare can cover several installed spans on site. Zero drift is held to 0.2 % of URL over five years, which keeps the calibration interval long on clean, dry service.
Electronics
Output is 4-20 mA with selectable HART revision 5 or 7, or a 1-5 V low-power circuit. A local LCD shows the process variable and lets a technician trim the loop without a communicator.
Approvals and assemblies
SIL 2/3 certification to IEC 61508 is available, along with explosion-proof, flameproof and intrinsically safe approvals. Because the body is Coplanar, manifolds, seals and primary elements are selected from the option groups rather than added in the field.
Manufacturer reference: Emerson document 00813-0100-4001.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Coplanar piezoresistive sensor for differential and gauge pressure |
| Accuracy | 0.075 % of span reference accuracy; 0.05 % high-accuracy option |
| Process temperature | -46 to 121 C (-50 to 250 F) depending on fill fluid |
| Pressure rating | Up to 2000 psi (137.9 bar) static on the highest differential code |
| Process connection | Coplanar flange with 1/4-18 NPT; manifold or diaphragm seal mounts directly |
| Enclosure rating | NEMA 4X / IP65, IP66, IP67 |
| Output signal | 4-20 mA HART (rev 5/7 selectable) or 1-5 V low-power HART |
| Power supply | 10.5 to 42.4 Vdc (HART, loop powered) |
| Wetted materials | 316L stainless steel, Alloy C-276 and Monel options |
| Diagnostics | HART diagnostics on the 4-20 mA loop; local LCD available |
| Certifications | SIL 2/3 (IEC 61508); explosion-proof, flameproof and intrinsically safe options |
| Pressure range | Differential -25 to 25 inH2O up to -2000 to 2000 psi; gauge -14.2 to 2000 psi |