Overview

Integral orifice flowmeter pairing the 2051C differential pressure transmitter with a honed-body, self-centering primary element for 1/2 to 1 1/2 in lines.

Key features

  • Integral orifice flowmeter combining the 2051C DP transmitter with a honed-body primary element
  • Line sizes 1/2, 1 and 1 1/2 in (15, 25 and 40 mm); bore sizes 0.010 to 1.100 in
  • Flow reference accuracy from +/-2.25% of flow rate at 5:1 turndown
  • 2051C reference accuracy +/- (0.025% URL + 0.125% span); stability +/-0.125% URL for 5 years
  • 4-20 mA with HART as standard, or 1-5 Vdc HART low power, FOUNDATION Fieldbus, PROFIBUS PA
  • 316 stainless steel body and plate; supplied assembled and leak tested

Key specifications

Accuracy
Flow reference accuracy at 5:1 turndown: +/-2.25% for bores 0.500 to 1.000 in, +/-2.75% for 0.160 to under 0.500 in, +/-3.10% below 0.160 in and +/-3.00% above 1.000 in; 2051C reference accuracy +/- (0.025% of URL + 0.125% of span) from 1:1 to 5:1
Pressure rating
Process connections flanged to ANSI and DIN classes, raised face or ring joint, slip-on or weld-neck, plus threaded and beveled ends; pressure limit follows the flange class ordered
Output signal
4-20 mA with HART digital signal as standard; 1-5 Vdc HART low power, FOUNDATION Fieldbus and PROFIBUS PA available
Power supply
External supply, 10.5 to 42.4 Vdc with no load for 4-20 mA HART; maximum loop resistance = 43.5 x (supply voltage - 10.5); long-term stability +/-0.125% of URL for five years on ranges 2 to 5
Measurement range
Line sizes 1/2, 1 and 1 1/2 in (15, 25 and 40 mm); bore sizes from 0.010 to 1.100 in
Application
Integral orifice flow measurement in 1/2 to 1 1/2 in lines, pairing a 2051C differential pressure transmitter with a honed-body primary element