Rosemount 2051CFP Integral Orifice Flowmeter
Purchase options
From$1,495.73
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Integral orifice flowmeter pairing the 2051C differential pressure transmitter with a honed-body, self-centering primary element for 1/2 to 1 1/2 in lines.
Key features
- Integral orifice flowmeter combining the 2051C DP transmitter with a honed-body primary element
- Line sizes 1/2, 1 and 1 1/2 in (15, 25 and 40 mm); bore sizes 0.010 to 1.100 in
- Flow reference accuracy from +/-2.25% of flow rate at 5:1 turndown
- 2051C reference accuracy +/- (0.025% URL + 0.125% span); stability +/-0.125% URL for 5 years
- 4-20 mA with HART as standard, or 1-5 Vdc HART low power, FOUNDATION Fieldbus, PROFIBUS PA
- 316 stainless steel body and plate; supplied assembled and leak tested
Key specifications
- Accuracy
- Flow reference accuracy at 5:1 turndown: +/-2.25% for bores 0.500 to 1.000 in, +/-2.75% for 0.160 to under 0.500 in, +/-3.10% below 0.160 in and +/-3.00% above 1.000 in; 2051C reference accuracy +/- (0.025% of URL + 0.125% of span) from 1:1 to 5:1
- Pressure rating
- Process connections flanged to ANSI and DIN classes, raised face or ring joint, slip-on or weld-neck, plus threaded and beveled ends; pressure limit follows the flange class ordered
- Output signal
- 4-20 mA with HART digital signal as standard; 1-5 Vdc HART low power, FOUNDATION Fieldbus and PROFIBUS PA available
- Power supply
- External supply, 10.5 to 42.4 Vdc with no load for 4-20 mA HART; maximum loop resistance = 43.5 x (supply voltage - 10.5); long-term stability +/-0.125% of URL for five years on ranges 2 to 5
- Measurement range
- Line sizes 1/2, 1 and 1 1/2 in (15, 25 and 40 mm); bore sizes from 0.010 to 1.100 in
- Application
- Integral orifice flow measurement in 1/2 to 1 1/2 in lines, pairing a 2051C differential pressure transmitter with a honed-body primary element
The same small-bore element, with the 2051 on top
The Rosemount 2051CFP is the integral orifice flowmeter built around the 2051C differential pressure transmitter. The element is the honed spool with a self-centering plate; the transmitter bolts straight to it, so the impulse tubing between them does not exist.
Why buy the assembled pair
A primary element and a DP transmitter bought separately have to be joined correctly: two impulse lines, the right slope, a manifold, and a leak test that nobody enjoys. The 2051CFP arrives assembled and leak tested, with the transmitter already matched to the element. That removes a whole class of installation error — and on a half-inch line, where a blocked or gas-filled impulse leg shifts the reading rather than killing it, those errors are the ones that survive for months.
Accuracy at 5:1 turndown
Flow reference accuracy is ±2.25% of flow rate for bores from 0.500 to 1.000 in, ±2.75% from 0.160 to under 0.500 in, ±3.10% below 0.160 in and ±3.00% above 1.000 in. Note the turndown: 5:1, not 8:1. An orifice plate's usable range is bounded by the square-root relationship between differential pressure and flow, and quoting a wider turndown would flatter the number without describing the installation.
Transmitter performance
The 2051C contributes a reference accuracy of ±(0.025% of URL + 0.125% of span) from 1:1 to 5:1, and long-term stability of ±0.125% of URL for five years on ranges 2 to 5. Output is 4-20 mA with HART, drawing 10.5 to 42.4 Vdc with no load and a maximum loop resistance of 43.5 times the supply voltage minus 10.5; 1-5 Vdc HART low power, FOUNDATION Fieldbus and PROFIBUS PA are available as alternatives.
Element and connections
Line sizes are half-inch, one-inch and inch-and-a-half (15, 25 and 40 mm), with bore sizes from 0.010 to 1.100 in. The body is a precision honed pipe section with the plate self-centering inside it, 316 stainless steel body and plate as standard. Process connections follow the flange class — ANSI and DIN raised face or ring joint, slip-on or weld-neck, plus threaded and beveled ends — and the pressure limit therefore follows the flange rating ordered.
Where it fits
Small-line flow where the plant standard is the 2051: chemical injection, dosing skids, utility lines, pilot plants. If the site standard is the 3051 instead, the 3051CFP is the same element with the other transmitter — the choice is usually made by what the maintenance team already stocks.
Manufacturer reference: Rosemount DP Flow Meters and Primary Elements Product Data Sheet, 00813-0100-4484, March 2023.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Flow reference accuracy at 5:1 turndown: +/-2.25% for bores 0.500 to 1.000 in, +/-2.75% for 0.160 to under 0.500 in, +/-3.10% below 0.160 in and +/-3.00% above 1.000 in; 2051C reference accuracy +/- (0.025% of URL + 0.125% of span) from 1:1 to 5:1 |
| Pressure rating | Process connections flanged to ANSI and DIN classes, raised face or ring joint, slip-on or weld-neck, plus threaded and beveled ends; pressure limit follows the flange class ordered |
| Output signal | 4-20 mA with HART digital signal as standard; 1-5 Vdc HART low power, FOUNDATION Fieldbus and PROFIBUS PA available |
| Power supply | External supply, 10.5 to 42.4 Vdc with no load for 4-20 mA HART; maximum loop resistance = 43.5 x (supply voltage - 10.5); long-term stability +/-0.125% of URL for five years on ranges 2 to 5 |
| Measurement range | Line sizes 1/2, 1 and 1 1/2 in (15, 25 and 40 mm); bore sizes from 0.010 to 1.100 in |
| Application | Integral orifice flow measurement in 1/2 to 1 1/2 in lines, pairing a 2051C differential pressure transmitter with a honed-body primary element |
| Mounting | Honed pipe section with self-centering plate and the 2051C transmitter mounted directly on the element; supplied fully assembled and leak tested |
| Material of construction | 316 stainless steel honed body and 316 stainless steel orifice plate as standard |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer