Rosemount 2051HT Hygienic Pressure Transmitter
Purchase options
From$481.08
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Hygienic in-line pressure transmitter with 3-A and EHEDG conformance, 32 micro-inch Ra, Tri-Clamp connection, 0.1 percent of span and SIP/CIP to 150 C.
Key features
- Hygienic in-line pressure transmitter conforming to 3-A and EHEDG, with 32 micro-inch (0.8 micrometre) Ra polished wetted surfaces
- Reference accuracy up to 0.1 percent of SPAN with 50:1 rangeability - a span-based figure, not a reading-based one
- Accuracy option B gives 0.10 percent with 2-year stability on ranges 1-3 but only 6-month stability on range 0
- Rated for SIP and CIP process temperatures up to 302 F (150 C)
- Free of voids and crevices: 3-A and EHEDG assess cleanability and geometry, not just material, so a threaded body would fail either
- Tri-Clamp sanitary connection with no impulse piping or manifold, and an optional Local Operator Interface for configuration at the instrument
Key specifications
- Accuracy
- Reference accuracy up to 0.1 percent of SPAN. Option B is 0.10 percent span with 2-year stability on ranges 1-3 but only 6-month stability on range 0; option C is 0.20 percent with 1-year stability, also 6 months on range 0
- Output signal
- 4-20 mA with HART. Optional Local Operator Interface allows configuration at the instrument without a handheld or a laptop
- Diagnostics
- 3-A and EHEDG conformance is a statement about cleanability, not about material: the body is free of voids and crevices and the wetted surfaces are polished to 32 micro-inch (0.8 micrometre) Ra. A 316L transmitter with a threaded body would carry neither certification, and the difference is invisible in a photograph
- Pressure range
- In-line gauge and absolute ranges in four range codes (range 0 through 3) with 50:1 rangeability, so a narrow span can be configured around the real operating point instead of accepting the full sensor range
- Variants
- Hygienic in-line with Tri-Clamp sanitary process connection. Accuracy options B (0.10 percent, 2-year stability) and C (0.20 percent, 1-year), with range 0 limited to 6-month stability on either. Optional Local Operator Interface
- Application
- Pressure and level measurement in dairy, beverage, brewing, pharmaceutical and biotech: vessel head pressure, transfer line pressure, filter and separator differential, and CIP supply pressure
0.1 percent — and the two words after it matter more than the number
The Rosemount 2051HT is a hygienic in-line pressure transmitter for life science, food and beverage: a 3-A and EHEDG conformant design with 32 µin Ra polished wetted surfaces, rated for SIP/CIP to 302 °F (150 °C), with reference accuracy up to 0.1 percent and 50:1 rangeability.
"Of span", not "of reading"
The 0.1 percent here is 0.1 percent of span. That is the conventional way process transmitters are specified, and it is not the same claim as an accuracy quoted against reading. On a span-based figure, the error in absolute terms is fixed by the configured span: set the span to 150 psi and 0.1 percent is 0.15 psi whether you are measuring at 150 psi or at 15. At the bottom of the range that same 0.15 psi is one percent of the value you are reading.
This matters in a hygienic process more than it looks, because the interesting measurements often sit low in the range: a vessel blanketed at a few psi, a filter differential near the clean end, a transfer line running at a fraction of its design pressure. The 50:1 rangeability helps here — it lets you configure a narrower span around the actual operating point instead of accepting the full sensor range — but the rangeability is a configuration freedom, not an accuracy guarantee. Narrow the span to where you work, then read the figure against that span.
The accuracy option and the range interact
The ordering table makes the interaction explicit rather than hiding it. Option B is 0.10 percent span accuracy with 2-year stability for ranges 1 through 3, but only 6-month stability on range 0. Option C is 0.20 percent with 1-year stability, and 6-month on range 0. So the most accurate configuration is not available with the longest stability interval on the lowest range — a detail that only surfaces when the model code is built, and one that decides how often the instrument needs a calibration check.
Ra 32 µin and "free of voids and crevices"
Two separate claims are being made, and both are needed. The surface finish of 32 µin (0.8 µm) is a roughness specification, and roughness is where cleaning fails: a caustic or acid wash removes soil from a smooth surface, but a biofilm that has established in a scratch pattern is not removed by flow. The second claim is geometric — the stainless design is free of voids and crevices, which is what 3-A and EHEDG actually assess. A crevice is worse than a rough patch, because no flow reaches it at all, and a thread or a step is where product sits and grows between washes.
This is why the certifications are on the datasheet at all. 3-A and EHEDG conformance is a statement about cleanability, not about material: a 316L transmitter with a threaded body would be neither, and the difference is invisible in a photograph.
SIP and CIP, stated as a temperature
The rating is up to 302 °F (150 °C) for steam-in-place and clean-in-place cycles. What the number does not tell you is that a SIP cycle is a thermal shock event, not a steady condition: the instrument goes from ambient to steam and back on a schedule, and the cycles add up. The 150 °C limit is the ceiling for each cycle, and the seal and fill fluid are what actually experience the fatigue — which is why the process connection and the fill system, not the electronics, are the parts to watch on a transmitter that is steamed daily.
In-line, which is the whole mechanical story
The 2051HT is an in-line instrument: one process connection, a Tri-Clamp sanitary fitting, mounted directly in the line or on the vessel. There is no impulse piping and no manifold, and on a hygienic process that is a requirement rather than a simplification — a dead leg of impulse tube is an uncleanable volume, and it is the first thing an audit finds. The optional Local Operator Interface allows configuration at the instrument without a handheld, which on a washdown area is a practical choice rather than a convenience.
Where it fits
Pressure and level measurement in dairy, beverage, brewing, pharmaceutical and biotech processes: vessel head pressure, transfer line pressure, filter and separator differential, and CIP supply pressure. It is the standard-platform hygienic transmitter — where the application needs 3-A and EHEDG conformance, a 32 µin finish and a clamp connection rather than the highest available performance class.
Manufacturer reference: Rosemount 2051HT Hygienic Pressure Transmitter Product Data Sheet for ordering information, accuracy and stability by range, and SIP/CIP limits.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Reference accuracy up to 0.1 percent of SPAN. Option B is 0.10 percent span with 2-year stability on ranges 1-3 but only 6-month stability on range 0; option C is 0.20 percent with 1-year stability, also 6 months on range 0 |
| Output signal | 4-20 mA with HART. Optional Local Operator Interface allows configuration at the instrument without a handheld or a laptop |
| Diagnostics | 3-A and EHEDG conformance is a statement about cleanability, not about material: the body is free of voids and crevices and the wetted surfaces are polished to 32 micro-inch (0.8 micrometre) Ra. A 316L transmitter with a threaded body would carry neither certification, and the difference is invisible in a photograph |
| Pressure range | In-line gauge and absolute ranges in four range codes (range 0 through 3) with 50:1 rangeability, so a narrow span can be configured around the real operating point instead of accepting the full sensor range |
| Variants | Hygienic in-line with Tri-Clamp sanitary process connection. Accuracy options B (0.10 percent, 2-year stability) and C (0.20 percent, 1-year), with range 0 limited to 6-month stability on either. Optional Local Operator Interface |
| Application | Pressure and level measurement in dairy, beverage, brewing, pharmaceutical and biotech: vessel head pressure, transfer line pressure, filter and separator differential, and CIP supply pressure |
| Mounting | Direct in-line or vessel mounting on a Tri-Clamp fitting with no impulse piping and no manifold - on a hygienic process a dead leg of impulse tube is an uncleanable volume and the first thing an audit finds |
| Operating temperature (°C) | SIP and CIP process temperatures up to 302 F (150 C). A SIP cycle is a thermal shock event rather than a steady condition, so the seal and fill system carry the fatigue rather than the electronics |