Rosemount 2120 Liquid Level Switch
Purchase options
From$278.91
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Short-fork vibrating level switch for high, low or pump-protection duty. It needs no calibration, fits small nozzles and shallow vessels, and offers relay, NAMUR or 8/16 mA output.
Key features
- Short vibrating fork, suited to small pipes, sumps and shallow vessels
- No calibration — the trip point is set by where the fork is mounted
- Works on water, viscous and coating liquids
- Threaded or flanged mounting, 316L stainless steel fork
- Direct load (relay), NAMUR or 8/16 mA output
- Aluminium or stainless housing sealed to IP66/IP67
Key specifications
- Measurement principle
- Short vibrating fork — frequency shift when the tines are covered
- Process temperature
- -40 to 150 C (-40 to 302 F) depending on housing and seal
- Pressure rating
- Set by the process connection selected
- Process connection
- Threaded or flanged, side or top mounting
- Enclosure rating
- IP66 / IP67; aluminium or stainless steel housing
- Output signal
- Direct load (relay), NAMUR or 8/16 mA
What this switch is
The 2120 is a short-fork vibrating level switch. The two tines sit at the tip of the probe and vibrate at their resonant frequency in air; when the product covers them the frequency shifts and the output changes state. The short fork is the reason it fits into small pipes, shallow sumps and vessels where a long probe would not reach or would touch the wall.
Where it is used
High-level alarm, low-level cut-out, pump protection and overfill prevention — the duties where a switch has to be right every time and never needs calibrating. It works on liquids from water to viscous products, and the short fork makes it a natural fit for small diameter lines.
Installation
- Threaded or flanged connection, mounted from the side or the top of the vessel.
- 316L stainless steel fork, with corrosion-resistant and hygienic options.
- Aluminium or stainless housing, IP66/IP67.
Output and safety
Output options cover direct load switching (relay), NAMUR and 8/16 mA, so the switch can feed a PLC input, a relay panel or a safety loop. Fail-safe direction is set by a link or by the wiring, not by a calibration step.
Why a short fork
Fork length sets how deep the switch has to enter the vessel. A short fork needs less insertion, which matters on a small nozzle, an insulated tank or a line where the probe would otherwise foul on a baffle.
Manufacturer reference: Emerson document 00813-0100-4030.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Short vibrating fork — frequency shift when the tines are covered |
| Process temperature | -40 to 150 C (-40 to 302 F) depending on housing and seal |
| Pressure rating | Set by the process connection selected |
| Process connection | Threaded or flanged, side or top mounting |
| Enclosure rating | IP66 / IP67; aluminium or stainless steel housing |
| Output signal | Direct load (relay), NAMUR or 8/16 mA |
| Power supply | 19 to 253 Vac/dc on relay versions; 8.2 Vdc on NAMUR |
| Wetted materials | 316L stainless steel fork; corrosion-resistant and hygienic options |
| Certifications | Explosion-proof, flameproof and intrinsically safe approvals |
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer