Rosemount 2160 Wireless Level Switch
No product images are published for this product yet.
Purchase options
From$769.52
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
WirelessHART vibrating fork point level switch: minimum density 500 kg/m3, -70 to 260 C, TUV approved for overfill protection, no wiring at the tank.
Key features
- WirelessHART vibrating fork point level switch, unaffected by flow, bubbles and turbulence
- Minimum liquid density 31.2 lb/ft3 (500 kg/m3), viscosity 0.2 to 10,000 cP, maximum solid particle 0.2 in. (5 mm) with no fork bridging
- Fast Drip fork design shortens wet-to-dry time in viscous liquids, so the switch does not stay wet after the level drops
- High temperature version -94 to 500 F (-70 to 260 C); hygienic connections to 435 psig (30 bar g), flanged to Class 600 rating with temperature derating
- TUV tested and approved for overfill protection, with electronic self-checking and condition monitoring alerts
- Software adjustable switching delay filters chatter in turbulent service; optional integral LCD for dry/wet, electronics temperature, fork frequency and supply voltage
Key specifications
- Accuracy
- Point switch, not a measurement: the output is wet or dry. Minimum liquid density 31.2 lb/ft3 (500 kg/m3) is the sizing limit that disqualifies light hydrocarbons and solvents, and viscosity range is 0.2 to 10,000 cP
- Output signal
- WirelessHART (IEC 62591) at 2.4 GHz DSSS, maximum 10 mW (10 dBm) EIRP, reporting the switch state over the encrypted mesh; optional integral LCD shows dry/wet, electronics temperature, fork frequency and supply voltage
- Diagnostics
- Electronic self-checking and condition monitoring with alerts, a 'locate device' function for commissioning, and a software adjustable switching delay that prevents false switching in turbulent service. TUV tested and approved for overfill protection. Power module ships separately
- Pressure range
- Hygienic connections 435 psig (30 bar g); flanged versions use the lower of process pressure and flange rating - ASME B16.5 Class 150 275 psig, Class 300 720 psig, Class 600 1440 psig at 100 F (38 C), all derating with temperature
- Variants
- Materials 316/316L stainless (dual certified) with a hand-polished better than 0.4 micrometre option on tri-clamp, or Alloy C / Alloy C-276 for flanged and selected threaded connections. Extended fork lengths to 118.1 in. (3000 mm), minimum 3.5 to 4.1 in. depending on connection
- Application
- High and low level alarms on tanks that were never wired, pump protection, overfill protection where the TUV approval is part of the safety case, and hygienic service up to 30 bar with a hand-polished fork option better than 0.4 micrometre for tri-clamp
A point level switch that has to be told apart from a float
The Rosemount 2160 is a vibrating fork level switch with a WirelessHART radio: a tuning fork that oscillates at its natural frequency, with the electronics watching for the frequency shift that occurs when the fork is covered. It is a point switch, not a continuous measurement — it says wet or dry, at one level — and the reason to choose it over a float or a capacitance probe is what it does at the two extremes: it is practically unaffected by flow, bubbles and turbulence, and it is not fooled by a coating the way an optical or conductive probe is.
The number that disqualifies an application before anything else
Minimum liquid density is 31.2 lb/ft³ (500 kg/m³). That single figure rules out light hydrocarbons, solvents and many liquefied gases, and it does so quietly — a fork in a low-density liquid still oscillates, just without enough frequency change to be a reliable switch. It is the first thing to check against the product's data sheet, before temperature, before materials, before anything on the process connection. Viscosity, by contrast, is generous: 0.2 to 10,000 cP.
Fast Drip, and why a fork shape is a maintenance feature
In a viscous product the failure mode of a vibrating fork is not switching too late — it is staying wet after the level has dropped, because the liquid clings between the forks and keeps damping them. The 2160's "Fast Drip" fork design is shaped to shed the film faster, which shortens the wet-to-dry time and makes the switch usable in syrups, slurries and coating liquids where a plain fork would read dry as wet for minutes. On a pump-protection duty, that delay is the difference between a dry-run trip and a burnt pump.
Solids, bridging and the tuning that is not mechanical
Maximum recommended solid particle diameter is 0.2 in (5 mm), with the explicit warning to avoid bridging between the forks. A fibrous or stringy solid that wraps the fork gives a permanent wet signal that no amount of cleaning schedule fixes. Where the problem is turbulence rather than solids, the answer is in the electronics: the switching delay is software adjustable, so a switch that chatters in a stirred vessel is filtered in configuration rather than relocated to a quieter part of the tank.
Temperature, pressure and where the approvals matter
The high temperature version runs from -94 to 500 °F (-70 to 260 °C). Maximum operating pressure is 435 psig (30 bar g) on hygienic connections, or the lower of process pressure and flange rating on flanged versions — Class 150 is 275 psig, Class 300 is 720 psig and Class 600 is 1440 psig at 100 °F, all of which derate with temperature. The switch is TÜV tested and approved for overfill protection, and that is worth separating from the marketing: an overfill switch is a safety function, and the approval is what makes it one rather than just an alarm.
Wireless, and what "install and forget" means in practice
The radio is IEC 62591 (WirelessHART) at 2.4 GHz with a maximum of 10 mW EIRP, and the switch reports its state over the encrypted mesh. It carries electronic self-checking and condition monitoring with alerts, a 'locate device' function for commissioning, and an optional integral LCD that can show dry/wet, electronics temperature, fork frequency and supply voltage. The fork sensor needs very little power, so the power module life stays long even at fast update rates — which for a point switch is a more comfortable position than for a continuous transmitter, because the data is a state change rather than a trend. The power module ships separately, which is worth knowing when the switch arrives without one.
Where it fits
High and low level alarms on tanks that were never wired, pump protection, overfill protection on a vessel where the TÜV approval is part of the safety case, and hygienic service up to 30 bar with a hand-polished fork option better than 0.4 μm for tri-clamp connections. It is also the practical answer where a float switch would be jammed by coating or a capacitance probe by a changing dielectric.
Manufacturer reference: Rosemount 2160 Wireless Level Switch Product Data Sheet 00813-0100-4160, performance and physical specifications.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Point switch, not a measurement: the output is wet or dry. Minimum liquid density 31.2 lb/ft3 (500 kg/m3) is the sizing limit that disqualifies light hydrocarbons and solvents, and viscosity range is 0.2 to 10,000 cP |
| Output signal | WirelessHART (IEC 62591) at 2.4 GHz DSSS, maximum 10 mW (10 dBm) EIRP, reporting the switch state over the encrypted mesh; optional integral LCD shows dry/wet, electronics temperature, fork frequency and supply voltage |
| Diagnostics | Electronic self-checking and condition monitoring with alerts, a 'locate device' function for commissioning, and a software adjustable switching delay that prevents false switching in turbulent service. TUV tested and approved for overfill protection. Power module ships separately |
| Pressure range | Hygienic connections 435 psig (30 bar g); flanged versions use the lower of process pressure and flange rating - ASME B16.5 Class 150 275 psig, Class 300 720 psig, Class 600 1440 psig at 100 F (38 C), all derating with temperature |
| Variants | Materials 316/316L stainless (dual certified) with a hand-polished better than 0.4 micrometre option on tri-clamp, or Alloy C / Alloy C-276 for flanged and selected threaded connections. Extended fork lengths to 118.1 in. (3000 mm), minimum 3.5 to 4.1 in. depending on connection |
| Application | High and low level alarms on tanks that were never wired, pump protection, overfill protection where the TUV approval is part of the safety case, and hygienic service up to 30 bar with a hand-polished fork option better than 0.4 micrometre for tri-clamp |
| Mounting | Threaded, tri-clamp or flanged process connections, suitable for horizontal and vertical installation. Maximum recommended solid particle diameter 0.2 in. (5 mm), and bridging between the forks has to be avoided |
| Operating temperature (°C) | High temperature version -94 to 500 F (-70 to 260 C); the standard version covers the more usual process range, and the electronics housing is rated for its own ambient limits |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer