Overview
Quik-Loc mounting kit (23757-00) for Rosemount 397 pH sensors on 1 inch tees: PEEK adapter, 316 stainless coupler and EP gasket.
Key features
- Quik-Loc mounting kit (23757-00) for Rosemount 397 pH sensors on 1 inch tees
- PEEK adapter, 316 stainless 1 inch MNPT coupler and EP gasket in one kit
- 1.4 inch insertion depth so the glass bulb reaches the flow
- Locking arms that give visual confirmation the sensor is seated
- Sensor removal without unscrewing the process connection or twisting the cable
- Not recommended for hazardous, corrosive or strongly oxidizing chemicals due to spray risk
Key specifications
- Diagnostics
- Emerson does not recommend this kit in processes with hazardous, corrosive or strongly oxidizing chemicals, because removing a sensor from a live line can spray process fluid
- Variants
- 23757-00 (this kit) for 1 inch tees at 1.4 inch insertion; 23757-01 for 1-1/2 in. and 2 in. tees at 2 inch insertion; individual parts 9160441, 23753-00, 23753-01 and 9160447 sold separately
- Application
- Quick-release mounting kit for a Rosemount 397 pH sensor installed in a 1 inch tee, allowing the sensor to be removed for cleaning or calibration without breaking the process connection
- Mounting
- Fits 1 inch tees with a 1.4 inch (36 mm) insertion depth; the coupler's locking arms close over the adapter and give visual confirmation that the sensor is seated
- Kit contents
- PEEK adapter 23753-01 (1.4 inch insertion depth), 316 stainless steel 1 inch MNPT coupler 9160441 and ethylene-propylene gasket 9160447
- Material of construction
- 316 stainless steel coupler, polyether ether ketone (PEEK) adapter and an ethylene-propylene (EP) gasket
The fitting that makes a pH sensor removable in seconds
The 23757-00 Quik-Loc kit is the mounting hardware for a Rosemount 397 pH sensor on a 1 inch tee: a PEEK adapter, a 316 stainless coupler and an EP gasket, arranged so the sensor can be pulled out for cleaning or calibration and pushed back without unscrewing anything and without twisting the cable.
What it replaces
The usual way to hold a pH sensor in a pipe is to thread it into a tee. That works until the sensor needs cleaning, and then someone has to break the process connection, turn the cable with the body and hope the thread re-seals. On a stream with suspended solids, cleaning is not occasional — it is the routine — so the mounting decides how much of the maintenance budget goes to the sensor.
How the locking works
The adapter is PEEK, sized for a 1.4 inch insertion depth so the glass bulb reaches into the flow without the body sitting in the stream. The coupler is 316 stainless with a 1 inch MNPT process connection and two locking arms that close over the adapter — and the arms give visual confirmation of the locked position, which is the feature that matters at 3 a.m. when nobody wants to guess whether a sensor is seated. An EP gasket seals the joint.
The version question
This kit is the 1 inch tee version with 1.4 inch insertion. The 23757-01 is the same idea for 1-1/2 and 2 inch tees with a 2 inch insertion depth, and the individual parts are available separately: 9160441 for the 1 inch 316 stainless coupler, 23753-01 and 23753-00 for the PEEK adapters, and 9160447 for the EP gasket. Ordering the kit rather than the parts is usually right, because a missing gasket stops the job.
Where it is not appropriate
Emerson explicitly does not recommend the Quik-Loc kit in processes with hazardous, corrosive or strongly oxidizing chemicals, because removing a sensor from a live line can spray process fluid. That is not a marketing caveat — it decides whether this mounting can be used at all on a given line, and it should be checked before the sensor is specified rather than after.
Where it fits
Rosemount 397 pH installations on 1 inch tees in wastewater, pulp and paper, lime slurry and food and beverage streams — anywhere the sensor is pulled for cleaning on a schedule and the line can be isolated first.
Manufacturer reference: Rosemount 397 TUpH pH Sensor Product Data Sheet, MS-00813-0100-3397, which lists 23757-00 as the Quik-Loc kit for 1 inch tees at 1.4 inch insertion depth.
Specifications
| Attribute | Value |
|---|---|
| Diagnostics | Emerson does not recommend this kit in processes with hazardous, corrosive or strongly oxidizing chemicals, because removing a sensor from a live line can spray process fluid |
| Variants | 23757-00 (this kit) for 1 inch tees at 1.4 inch insertion; 23757-01 for 1-1/2 in. and 2 in. tees at 2 inch insertion; individual parts 9160441, 23753-00, 23753-01 and 9160447 sold separately |
| Application | Quick-release mounting kit for a Rosemount 397 pH sensor installed in a 1 inch tee, allowing the sensor to be removed for cleaning or calibration without breaking the process connection |
| Mounting | Fits 1 inch tees with a 1.4 inch (36 mm) insertion depth; the coupler's locking arms close over the adapter and give visual confirmation that the sensor is seated |
| Kit contents | PEEK adapter 23753-01 (1.4 inch insertion depth), 316 stainless steel 1 inch MNPT coupler 9160441 and ethylene-propylene gasket 9160447 |
| Material of construction | 316 stainless steel coupler, polyether ether ketone (PEEK) adapter and an ethylene-propylene (EP) gasket |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer