Rosemount 24262-00 Replacement Anode/Cathode Cartridge
No product images are published for this product yet.
Purchase options
$590.07
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Replacement anode/cathode cartridge (24262-00) for the Rosemount Hx438 dissolved oxygen sensor, fitted when the sensor still responds sluggishly after a membrane change.
Key features
- Replacement anode/cathode cartridge for the Rosemount Hx438 dissolved oxygen sensor
- Part number 24262-00, listed in the Hx438 spares table
- Fitted after the membrane and electrolyte, only when the sensor still responds sluggishly or reads low in air
- Old cartridge pulls straight off the shaft; the new one is rotated to seat and pushed on
- Inspect the small O-ring above the cathode and renew the membrane with the cartridge
- Electrode surfaces must not be touched; flush with deionised water before assembly
Key specifications
- Diagnostics
- Replace when the sensor shows a sluggish response to saturated air or too small a current in air after the membrane and electrolyte have been renewed
- Application
- Replacement electrode assembly for the Rosemount Hx438 dissolved oxygen sensor, fitted when the sensor still responds sluggishly after a membrane and electrolyte change
- Mounting
- Membrane cartridge unscrewed, old cathode pulled straight off the shaft without turning, new cartridge rotated to seat and pushed onto the shaft; contacts dry and clean before assembly
- Transmitter compatibility
- Rosemount Hx438 dissolved oxygen sensor
- Kit contents
- One anode/cathode cartridge, part number 24262-00; membrane kit and electrolyte are separate parts
- Material of construction
- Metal electrode assembly with the small O-ring above the cathode, which is inspected and replaced if damaged when the cartridge is changed
The part that decides a dissolved oxygen sensor is finished
The 24262-00 is the replacement anode/cathode cartridge for the Rosemount Hx438 dissolved oxygen sensor. It is not a membrane, not an electrolyte refill and not a cleaning kit: it is the electrode assembly itself, and replacing it is the step that puts an aged sensor back into specification instead of replacing the whole unit.
When it is the right part
The Hx438 service procedure is specific about the order: replace the membrane and electrolyte first, and only if the sensor still shows a sluggish response to saturated air, or too small a current in air, replace the cathode. That sequence exists because a stretched membrane or a dry electrolyte produces exactly the same symptom — and changing the cartridge for a membrane problem wastes the part and a shutdown.
Fitting it
With the membrane cartridge unscrewed, the old cathode is pulled straight off the shaft — pull, do not turn — and the new cartridge is rotated until it seats, then pushed onto the shaft. Contacts must be dry and clean before it goes on, and the small O-ring above the cathode is inspected and replaced if damaged. The membrane has to be renewed whenever the cathode is replaced, so a membrane kit belongs in the same work order.
Handling
The anode and cathode surfaces are the measurement. They should not be touched: skin oils and contamination on the electrode are the fastest way to turn a new cartridge into a drifting one. Flush with deionised water and dry the metal parts before assembly, and keep the spare in its packaging until the sensor is open and ready.
Where it fits
Any Hx438 dissolved oxygen installation where the sensor responds slowly or reads low in air after a membrane and electrolyte change — fermentation, wastewater aeration basins, and industrial water loops where the DO probe is a consumable in a way the transmitter is not.
Manufacturer reference: Rosemount Hx438 Dissolved Oxygen Sensor Quick Start Guide, 00825-0100-3494, which lists 24262-00 in its spares table.
Specifications
| Attribute | Value |
|---|---|
| Diagnostics | Replace when the sensor shows a sluggish response to saturated air or too small a current in air after the membrane and electrolyte have been renewed |
| Application | Replacement electrode assembly for the Rosemount Hx438 dissolved oxygen sensor, fitted when the sensor still responds sluggishly after a membrane and electrolyte change |
| Mounting | Membrane cartridge unscrewed, old cathode pulled straight off the shaft without turning, new cartridge rotated to seat and pushed onto the shaft; contacts dry and clean before assembly |
| Transmitter compatibility | Rosemount Hx438 dissolved oxygen sensor |
| Kit contents | One anode/cathode cartridge, part number 24262-00; membrane kit and electrolyte are separate parts |
| Material of construction | Metal electrode assembly with the small O-ring above the cathode, which is inspected and replaced if damaged when the cartridge is changed |
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer