Rosemount 24361-00 Front Panel Assembly for 1056 (without HART)
No product images are published for this product yet.
Purchase options
$338.58
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Replacement front panel assembly for the Rosemount 1056 transmitter, without HART protocol - one digit from the HART variant 24361-01.
Key features
- Front panel assembly for the Rosemount 1056 transmitter: display window and keypad module, supplied WITHOUT HART protocol
- One digit separates it from the HART variant 24361-01, and the two look identical from the outside - a replacement panel must match the transmitter it goes into
- This is a module, not a transmitter: the 1056 carries the sensor inputs and measurement electronics, the panel is the part that faces the operator
- The panel is the part exposed to sun, chemical splash and gloved key presses for years, while the sealed electronics behind it do not see any of that
- The 1056 accepts single or dual sensor inputs, so on a dual-input installation this panel is the one interface through which two loops are read
Key specifications
- Accuracy
- Not applicable to the panel itself. It is the operator interface of the 1056, so measurement accuracy stays with the transmitter's electronics and sensor inputs
- Output signal
- No output of its own and no HART capability: this is the 24361-00 variant, supplied without HART protocol. The HART variant is 24361-01
- Diagnostics
- Compare panel legends and display type against the existing unit before ordering on a special or older build: the panel is matched to the transmitter configuration and not only to the model family
- Pressure range
- Not applicable - a front panel assembly carries no process connection and no wetted parts
- Variants
- 24361-00 front panel without HART protocol (this item) and 24361-01 front panel with HART protocol. The two are visually identical from the front, so the correct choice is decided by the transmitter being repaired, not by appearance
- Application
- Replacement front panel for a Rosemount 1056 transmitter: the display window and keypad module for an instrument whose panel is damaged, worn or weathered, on single or dual sensor input installations
One digit separates two front panels that look identical from the outside
The Rosemount 24361-00 is the front panel assembly for the 1056 transmitter — a direct replacement screen and keypad module. The part number carries one piece of information that matters more than anything else on this page: it is the variant without HART.
The pair that gets confused
| Part number | Front panel |
|---|---|
| 24361-00 | Assembly, front panel — without HART protocol |
| 24361-01 | Assembly, front panel — with HART protocol |
The two assemblies present the same face to the operator: the same display window, the same keypad, the same cut-out in the enclosure door. The difference is the electronics behind the panel and which transmitter configuration it completes. Ordering by photograph, or by a description that reads "front panel for 1056", is how the wrong one arrives — and the failure mode is not a panel that does not fit. It fits. It is the communication capability of the transmitter that ends up different from what the plant believed it had.
So the check is mechanical, and it is worth doing before the order rather than after: does the 1056 being repaired have HART, or not? A replacement panel has to match the transmitter it goes into, because the panel is part of the assembly that carries that capability.
An assembly is not a transmitter
This is a module, and the distinction matters for anyone expecting a working instrument to arrive. The 1056 is a four-wire transmitter with sensor inputs, measurement electronics and an enclosure; the front panel is the part that faces the operator. Replacement is the appropriate response when the display is damaged, the keypad has worn through, or the window has been attacked by the environment — and inappropriate when the fault is in the measurement.
Why the panel is the part that fails
On a transmitter mounted at the process, the front panel is the surface that takes everything the location can deliver: sun on the window, chemical splash on the keypad, gloves pressing the same four keys for years. The measurement electronics behind it sit in a sealed enclosure and do not see any of that.
That is the honest reason a panel is a stocked line item rather than a curiosity. The parts with the shortest life on an installed analyzer are usually not the ones doing the chemistry — they are the ones a person touches and the weather reaches.
The 1056 it belongs to
The 1056 accepts single or dual sensor inputs, which is Emerson's own framing of the value: two measurements in one instrument means one enclosure, one power feed, one display and one panel cut-out instead of two, which reduces the cost per loop and saves panel space. That is why the front panel is a meaningful part rather than a faceplate — on a dual-input installation it is the single interface through which two loops are read.
Ordering notes
Order by part number, and state whether the target transmitter has HART when asking for a quotation. Check the display type and keypad legends against the existing panel if the instrument is a special or older build, because the panel is matched to the transmitter configuration and not only to the model family. Keep the removed panel until the replacement is proven, since a panel that is only partly faulty still has a readable display and a usable keypad for comparison.
Manufacturer reference: Emerson product listing for the Rosemount 24361-00 front panel assembly (without HART protocol) for the 1056 transmitter, and the corresponding 24361-01 listing for the HART variant.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not applicable to the panel itself. It is the operator interface of the 1056, so measurement accuracy stays with the transmitter's electronics and sensor inputs |
| Output signal | No output of its own and no HART capability: this is the 24361-00 variant, supplied without HART protocol. The HART variant is 24361-01 |
| Diagnostics | Compare panel legends and display type against the existing unit before ordering on a special or older build: the panel is matched to the transmitter configuration and not only to the model family |
| Pressure range | Not applicable - a front panel assembly carries no process connection and no wetted parts |
| Variants | 24361-00 front panel without HART protocol (this item) and 24361-01 front panel with HART protocol. The two are visually identical from the front, so the correct choice is decided by the transmitter being repaired, not by appearance |
| Application | Replacement front panel for a Rosemount 1056 transmitter: the display window and keypad module for an instrument whose panel is damaged, worn or weathered, on single or dual sensor input installations |
| Mounting | Fitted into the 1056 enclosure as a direct replacement assembly. Retain the removed panel until the replacement is proven, since a partly faulty panel still offers a readable display and usable keypad for comparison |
| Operating temperature (°C) | Set by the transmitter's location. The panel is the surface exposed to sun, chemical splash and repeated gloved key presses, which is why it wears before the sealed electronics behind it |
Documents
No documents are published for this product yet.
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer