Rosemount 248 Wireless Temperature Transmitter
Purchase options
From$642.08
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Wireless temperature transmitter with universal T/C, RTD, mV and ohm input, 1 s to 60 min update rate, and 10 year battery at one-minute updates.
Key features
- Wireless temperature transmitter for monitoring, with universal single-channel input: thermocouple, RTD in 2, 3 or 4 wire, millivolt and ohms
- WirelessHART at 2.4 GHz with a user-selectable update rate from 1 second to 60 minutes - a 3,600 to one range that sets the battery budget
- 10 year power module life stated at a ONE MINUTE update rate, 21 C reference and routing data for three additional network devices
- Routing for neighbours is a mesh property, not a setting: a device that relays for more than three spends energy on other people's data
- Ambient temperature compensation keeps the published accuracy meaningful once the transmitter sits on a hot pipe in the sun
- Accuracy +/-0.81 F (+/-0.45 C) for a Pt100 at a 20 C reference, published per sensor type; the green SmartPower module 701PGNKF ships separately
Key specifications
- Accuracy
- +/-0.81 F (+/-0.45 C) for a Pt100 at a 20 C reference, published per sensor type in the accuracy table across thermocouple, RTD, millivolt and ohm inputs. Ambient temperature compensation keeps the figure meaningful once the housing is at process-adjacent temperature
- Output signal
- IEC 62591 (WirelessHART) at 2.4 GHz, 15 channels, 2,400 to 2,485 GHz. User-selectable update rate from 1 second to 60 minutes
- Diagnostics
- Power module life is rated 10 years at a ONE MINUTE update rate, at 21 C reference, and while routing data for three additional network devices. Routing for neighbours is a mesh property rather than a setting, so a device that relays for more than three spends energy on other devices' data and its life falls accordingly
- Pressure range
- Not applicable - the transmitter mounts at the sensor or thermowell; process pressure belongs to the sensor, thermowell and connection
- Variants
- Single sensor channel with universal input: thermocouple, RTD in 2-, 3- or 4-wire, millivolt and ohm. Internal antenna compatible with the green power module, which must be ordered separately as model 701PGNKF
- Application
- Temperature monitoring where the value is visibility rather than control: bearing and surface temperatures on rotating equipment, temperature profiles across a tank farm or reactor, heat-tracing verification, and points never instrumented because cable cost exceeded instrument cost
The ten-year battery is a claim with three conditions
The Rosemount 248 is a wireless temperature transmitter for monitoring: a single-channel device with universal sensor inputs — thermocouple, RTD in 2-, 3- or 4-wire, millivolt and ohms — reporting over WirelessHART at 2.4 GHz. Its published power module life is 10 years, and that figure is worth reading as carefully as the accuracy.
What the ten years is measured at
The datasheet states the conditions beside the number: a one-minute update rate, at 70 °F (21 °C) reference conditions, and routing data for three additional network devices. Each of those is a variable in a real installation.
- The update rate is a dial from 1 second to 60 minutes — a range of 3,600 to one. The radio's energy budget is dominated by how often it transmits, so the life figure belongs to the one-minute setting. A monitoring point that needs a faster update is buying that responsiveness with battery life, and the honest way to plan is to choose the update rate first and read the life at that rate, not to quote ten years and then set the rate to ten seconds.
- The 21 °C reference is an indoor number. Continuous exposure to the ambient limits may reduce the specified life by less than 20 percent, which is a reassuring statement — but it is a statement about ambient, not about the device being in full sun on a hot pipe.
- Routing for three additional devices is the condition people miss, because it is a property of the network rather than of the setting. In a WirelessHART mesh a device does not merely transmit its own measurement; it relays for its neighbours. A transmitter that ends up routing for five or six devices spends energy on other people's data, and its life falls accordingly. That is not a fault — it is the mesh working — but it means battery life in a dense network is not a per-device calculation.
Universal input is the cost argument
One channel accepts thermocouple, RTD (2-, 3- and 4-wire), millivolt and ohm inputs. On a plant with mixed sensor types, that is one part number to stock instead of one per sensor family, and it means a monitoring point can be re-purposed without changing the transmitter. The accuracy table is published per sensor type rather than as a single figure, which is the honest form: ±0.81 °F (±0.45 °C) for a Pt100 at a 20 °C reference is the reference case, and other sensor types carry their own numbers.
Ambient compensation, which is what makes the number survive installation
The transmitter provides compensation for ambient temperature to enhance performance. This matters more on a wireless device than on a rack-mounted one, because the whole point is to mount it where a cable could not go: on a pipe, on a structure, in the sun, in a cold climate. A transmitter whose internal reference drifts with its own housing temperature reports a reading that moves with the weather, and on a monitoring point with no local reference that drift is indistinguishable from a process change. The compensation is what keeps the published accuracy meaningful once the device is bolted to something that is 60 °C in summer.
The power module is ordered separately
The green SmartPower module must be shipped separately as model 701PGNKF. It is the intrinsically safe, field-replaceable 3.6 V module used across the wireless range, and it is not in the box. That is a procurement detail with an obvious failure: a transmitter that arrives without a power module cannot be commissioned, and the delay lands on the installation crew rather than on the order desk.
Where it fits
Temperature monitoring where the value of the measurement is visibility rather than control: bearing and surface temperatures on rotating equipment, temperature profiles across a tank farm or a reactor, heat-tracing verification, and the points that were never instrumented because the cable cost exceeded the instrument cost. It is a monitoring device, and it should be chosen as one — with the update rate set to what the application actually needs, and the battery life planned from that rate rather than from the headline figure.
Manufacturer reference: Rosemount 248 Wireless Temperature Transmitter Product Data Sheet 00813-0100-4248 for input options and accuracy per sensor type, update rate, power module life conditions and ordering information.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | +/-0.81 F (+/-0.45 C) for a Pt100 at a 20 C reference, published per sensor type in the accuracy table across thermocouple, RTD, millivolt and ohm inputs. Ambient temperature compensation keeps the figure meaningful once the housing is at process-adjacent temperature |
| Output signal | IEC 62591 (WirelessHART) at 2.4 GHz, 15 channels, 2,400 to 2,485 GHz. User-selectable update rate from 1 second to 60 minutes |
| Diagnostics | Power module life is rated 10 years at a ONE MINUTE update rate, at 21 C reference, and while routing data for three additional network devices. Routing for neighbours is a mesh property rather than a setting, so a device that relays for more than three spends energy on other devices' data and its life falls accordingly |
| Pressure range | Not applicable - the transmitter mounts at the sensor or thermowell; process pressure belongs to the sensor, thermowell and connection |
| Variants | Single sensor channel with universal input: thermocouple, RTD in 2-, 3- or 4-wire, millivolt and ohm. Internal antenna compatible with the green power module, which must be ordered separately as model 701PGNKF |
| Application | Temperature monitoring where the value is visibility rather than control: bearing and surface temperatures on rotating equipment, temperature profiles across a tank farm or reactor, heat-tracing verification, and points never instrumented because cable cost exceeded instrument cost |
| Mounting | Mounted at the sensor or thermowell in the field, which is the point of the product - the locations a cable could not economically reach. Ambient temperature at the housing is the design consideration, not a cabinet condition |
| Operating temperature (°C) | Humidity limits 0 to 99 percent non-condensing. The transmitter provides compensation for ambient temperature; continuous exposure to the ambient limits may reduce power module life by less than 20 percent |
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer