Overview
Head-mount temperature transmitter with a HART digital signal on the 4-20 mA loop, universal RTD and thermocouple input, and +/-0.1 C annual stability.
Key features
- Head-mount temperature transmitter with HART digital signal superimposed on the 4-20 mA loop
- Universal user-selectable input: RTD, thermocouple, ohms and millivolt
- Stability of +/-0.1% of reading or 0.1 C for twelve months
- 12.0 to 42.4 Vdc at the terminals, loop resistance 250 to 1100 ohms
- -40 to 85 C operating, 0 to 99% non-condensing humidity
- NAMUR NE-21, NE-43 and NE-89; ATEX, IECEx, FM, CSA and China approvals by code
Key specifications
- Accuracy
- Stability +/-0.1% of reading or 0.1 °C, whichever is greater, for twelve months; supply voltage effect under +/-0.005% of span per volt; self-calibrating measurement circuitry
- Output signal
- Two-wire 4-20 mA, linear with temperature or input, with a digital HART signal superimposed on the loop (HART device revision 5.1)
- Power supply
- 12.0 to 42.4 Vdc at the transmitter terminals with loop resistance 250 to 1100 ohms; 17.75 Vdc minimum supply to drive a 250-ohm load; input/output isolation tested to 500 Vac rms
- Diagnostics
- Software-detected failure drives the output outside the measuring range: fail high 21 to 23 mA by default, fail low at or below 3.75 mA standard or 3.6 mA in NAMUR NE-43 mode
- Certifications
- ATEX, IECEx, FM, CSA and China approvals including intrinsic safety and Type n; meets NAMUR NE-21, NE-43 and NE-89
- Measurement range
- User-selectable universal input covering RTD, thermocouple, ohm and millivolt sensors
HART where the sensor is, not at the cabinet
The Rosemount 248H is a head-mount temperature transmitter that puts the conversion inside the sensor's connection head. It converts an RTD or thermocouple to a two-wire 4-20 mA signal with a digital HART signal superimposed on the same pair — so the loop carries the measurement and a configuration channel at the same time.
What that buys over the basic 148
The 148 sends a plain analog signal and is configured from a PC with an interface kit. The 248H speaks HART, which means it can be ranged, trimmed and diagnosed from the control room or from a field communicator clipped across the loop, without opening the housing. On a vessel with fifty temperature points, that difference decides how a technician spends the afternoon.
Built to stay in specification
Stability is ±0.1% of reading or 0.1 °C, whichever is greater, for twelve months; supply-voltage effect is under ±0.005% of span per volt; and the unit self-calibrates its measurement circuitry on every temperature update against internal references. Vibration is tested at 0.21 mm displacement from 10 to 60 Hz and 3 g peak from 60 to 2000 Hz with no effect on performance — the sort of numbers that matter when the transmitter is bolted to a compressor skid.
Loop details that bite at commissioning
Operating voltage is 12.0 to 42.4 Vdc at the terminals with a load between 250 and 1100 ohms, and a minimum of 17.75 Vdc supply is needed to drive a 250-ohm load — a loop powered from a marginal supply will look fine on the bench and fail on the wire. HART communication needs that 250-ohm minimum loop resistance, and the transmitter should not be interrogated below 12 V at its terminals.
Failure, stated plainly
Software-detected failures drive the output outside the measuring range — fail high 21 to 23 mA by default, fail low at or below 3.75 mA in standard mode or 3.6 mA in NAMUR NE-43 mode. Hardware failures such as a microprocessor fault always drive above 23 mA. The point is that a broken transmitter must not read like a plausible temperature.
Where it fits
Head-mount installations on RTD and thermocouple assemblies, ordered standalone or assembled to a sensor and thermowell, with ATEX, IECEx, FM, CSA and China approvals including intrinsic safety and Type n.
Manufacturer reference: Rosemount 248 Temperature Transmitter Reference Manual, 00809-0100-4825 Rev CB.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Stability +/-0.1% of reading or 0.1 °C, whichever is greater, for twelve months; supply voltage effect under +/-0.005% of span per volt; self-calibrating measurement circuitry |
| Output signal | Two-wire 4-20 mA, linear with temperature or input, with a digital HART signal superimposed on the loop (HART device revision 5.1) |
| Power supply | 12.0 to 42.4 Vdc at the transmitter terminals with loop resistance 250 to 1100 ohms; 17.75 Vdc minimum supply to drive a 250-ohm load; input/output isolation tested to 500 Vac rms |
| Diagnostics | Software-detected failure drives the output outside the measuring range: fail high 21 to 23 mA by default, fail low at or below 3.75 mA standard or 3.6 mA in NAMUR NE-43 mode |
| Certifications | ATEX, IECEx, FM, CSA and China approvals including intrinsic safety and Type n; meets NAMUR NE-21, NE-43 and NE-89 |
| Measurement range | User-selectable universal input covering RTD, thermocouple, ohm and millivolt sensors |
| Application | Head-mount temperature transmitter for a single measurement point, ordered standalone or assembled to a sensor and thermowell |
| Mounting | Head mount in a connection head or universal head, directly on the sensor assembly or apart from it using a universal head |
| Operating temperature (°C) | -40 to 85 °C (-40 to 185 °F) operating; -50 to 120 °C (-58 to 248 °F) storage; 0 to 99% relative humidity, non-condensing |