Rosemount 3051CFA Annubar Flow Meter
Purchase options
From$1,460.65
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Annubar averaging pitot flow meter with a 3051C transmitter, installed through a single tapping in 2 to 96 in lines, with +/-1.80% of flow rate accuracy at 8:1.
Key features
- Annubar averaging pitot flow meter with a 3051C differential pressure transmitter
- Installs through a single pipe tapping with no spool piece or flange pair
- Line sizes 2 to 96 in (50 to 2400 mm), with three sensor sizes covering the range
- Accuracy +/-1.80% of flow rate at 8:1 turndown
- 4-20 mA with HART standard, FOUNDATION Fieldbus and PROFIBUS PA available
- DA1 Loop Integrity and Plugged Impulse Line diagnostics, Bluetooth, backlit display with totalizer
Key specifications
- Accuracy
- +/-1.80% of flow rate at 8:1 flow turndown
- Output signal
- 4-20 mA with HART digital signal from the 3051C transmitter; FOUNDATION Fieldbus and PROFIBUS PA available
- Power supply
- Loop powered from the 3051C, 10.5 to 42.4 Vdc with no load
- Diagnostics
- Loop Integrity and Plugged Impulse Line diagnostics (code DA1); Bluetooth configuration (BLE), backlit graphical display with totalizer (M6) and safety certification with proof testing (QT, T9) available
- Measurement range
- Line sizes 2 to 96 in (50 to 2400 mm); sensor size 1 covers 2 to 8 in, size 2 covers 6 to 96 in and size 3 covers lines above 12 in
- Application
- Averaging pitot flow measurement on large lines and ducts, installed through a single pipe tapping with the 3051C transmitter mounted on the sensor head
An averaging pitot that goes in through one tapping
The Rosemount 3051CFA is an Annubar flow meter: a T-shaped averaging pitot sensor inserted across the pipe through a single tapping, with a 3051C differential pressure transmitter mounted on top. It measures the same differential pressure an orifice would, but it does not need a spool piece, a flange pair or a plate to be centred.
How an averaging pitot differs
An orifice forces the whole flow through a restriction and measures the pressure drop across it. An Annubar sits in the flow and samples the velocity profile at several points across the diameter, averaging them into a single differential pressure. That has two practical consequences: the pressure loss is far lower, and the sensor can be installed through one threaded or flanged connection instead of breaking the line.
Sizes and accuracy
Line sizes run from 2 to 96 in (50 to 2400 mm) — the range where an orifice plate becomes heavy, expensive and hard to centre. Accuracy is ±1.80% of flow rate at 8:1 turndown, which is competitive with a good orifice installation and better than a badly installed one. The turndown matters: 8:1 is the working range, not a lab number.
What the 3051C adds
The transmitter is the standard 3051C: 4-20 mA with HART, 10.5 to 42.4 Vdc with no load, with FOUNDATION Fieldbus and PROFIBUS PA available. Loop Integrity and Plugged Impulse Line diagnostics (DA1) watch the connection between sensor and transmitter, Bluetooth allows configuration without opening the housing, and the M6 display shows flow rate directly with a totalizer. The assembly arrives leak tested, so the field work is the tapping and the wiring.
Where it fits
Large ducts and stacks, water and wastewater lines, compressed air and gas headers, and any installation where the pressure loss of an orifice would cost real energy or where the line cannot be cut. It is also the practical answer when the straight run is short, because an averaging pitot tolerates a less settled profile than a plate.
Practical note on steam
On steam service the impulse connections between the sensor head and the transmitter are where problems appear: they must be short, properly sloped and insulated, and the DA1 diagnostics exist precisely because a plugged or wet leg leaves a reading that looks like a real flow.
Manufacturer reference: Rosemount DP Flow Meters and Primary Elements Product Data Sheet, 00813-0100-4484, March 2023.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | +/-1.80% of flow rate at 8:1 flow turndown |
| Output signal | 4-20 mA with HART digital signal from the 3051C transmitter; FOUNDATION Fieldbus and PROFIBUS PA available |
| Power supply | Loop powered from the 3051C, 10.5 to 42.4 Vdc with no load |
| Diagnostics | Loop Integrity and Plugged Impulse Line diagnostics (code DA1); Bluetooth configuration (BLE), backlit graphical display with totalizer (M6) and safety certification with proof testing (QT, T9) available |
| Measurement range | Line sizes 2 to 96 in (50 to 2400 mm); sensor size 1 covers 2 to 8 in, size 2 covers 6 to 96 in and size 3 covers lines above 12 in |
| Application | Averaging pitot flow measurement on large lines and ducts, installed through a single pipe tapping with the 3051C transmitter mounted on the sensor head |
| Mounting | T-shaped averaging pitot inserted across the pipe through one threaded or flanged connection; supplied fully assembled and leak tested, with no spool piece or flange pair required |
| Material of construction | 316 stainless steel sensor and wetted parts as standard, with alternative materials by model code |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer