Rosemount 3051CFC Compact Orifice Flow Meter
Purchase options
From$1,655.02
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Compact orifice flow meter built on the 3051C transmitter, with conditioning, plate or Annubar elements for 1/2 to 12 in lines, supplied assembled and leak tested.
Key features
- Compact orifice flow meter built on the 3051C differential pressure transmitter
- Element options: conditioning orifice plate (C), conventional plate (P) or Compact Annubar (A)
- Line sizes 1/2 to 12 in (15 to 300 mm); installs between existing raised-face flanges
- System reference accuracy from +/-1.75% of flow rate at 8:1 turndown (conditioning, beta 0.4)
- Loop Integrity and Plugged Impulse Line diagnostics (DA1) watch the impulse path
- Backlit graphical display with totalizer, Bluetooth configuration, safety certification options
Key specifications
- Accuracy
- System reference accuracy at 8:1 flow turndown: +/-1.75% of flow rate for a conditioning element at beta 0.4, +/-1.95% at beta 0.50 and 0.65, +/-2.00% for a conventional plate and +/-1.80% for a calibrated Annubar; add 0.5% outside 2 to 8 in line sizes on the plate option
- Output signal
- 4-20 mA with HART digital signal from the 3051C transmitter; the platform also supports FOUNDATION Fieldbus and PROFIBUS PA
- Power supply
- Loop powered from the 3051C transmitter, 10.5 to 42.4 Vdc with no load
- Diagnostics
- Loop Integrity and Plugged Impulse Line diagnostics (code DA1) detect impulse line problems; Bluetooth configuration (BLE), backlit graphical display with totalizer (M6) and safety certification with proof testing (QT, T9) available
- Measurement range
- Line sizes 1/2 to 12 in (15 to 300 mm); element options are a conditioning orifice plate (C), a conventional orifice plate (P) or a Compact Annubar averaging pitot (A)
- Application
- Compact differential pressure flow measurement for gas, liquid and steam, installed between existing raised-face flanges and supplied as an assembled, leak-tested meter
The 3051 version of the compact flow meter
The Rosemount 3051CFC is a compact orifice flow meter built around the 3051C differential pressure transmitter: an element that clamps between existing raised-face flanges, a manifold, and the transmitter, assembled and leak tested before shipping. It is the same idea as the 2051CFC with a different transmitter family underneath, and the accuracy figures differ accordingly.
Three element options again, one transmitter
Code C is the conditioning orifice plate, whose four-hole pattern reduces the straight run needed. Code P is a conventional orifice plate. Code A is a Compact Annubar averaging pitot, which is the choice when line size is large enough that a disc becomes unwieldy. Line sizes run from half-inch to 12 in (15 to 300 mm), so the same model covers a small utility line and a large gas header.
Accuracy at 8:1 turndown
With a 3051C transmitter the system holds ±1.75% of flow rate for a conditioning element at beta 0.4, ±1.95% at beta 0.50 and 0.65, ±2.00% for a conventional plate, and ±1.80% for a calibrated Annubar. The turndown here is 8:1, not the 5:1 used with the 2051 family — worth noticing if the two are being compared, because an accuracy figure quoted at a different turndown is not directly comparable.
Diagnostics that watch the impulse path
Loop Integrity and Plugged Impulse Line diagnostics (code DA1) detect problems in the connection between the element and the transmitter — the blocked or gas-filled leg that leaves a reading that looks plausible. On a steam line, a plugged impulse line is the classic failure that reads as a steady flow while the process has changed.
Installation and options
The assembly installs between existing raised-face flanges, is leak tested before shipment, and needs no spool piece. A backlit graphical display with local-language capability (M6) shows flow rate directly with an added totalizer, Bluetooth (BLE) allows configuration without opening the housing, and safety certification with proof testing (QT and T9) covers instrumented safety functions.
Where it fits
Steam, gas and liquid flow where the plant standard is the 3051 platform: boiler feedwater, plant air, fuel gas, and utility headers where a compact meter is preferable to a spool-piece installation. If the site stocks 2051 transmitters instead, the 2051CFC is the same meter with that transmitter.
Manufacturer reference: Rosemount DP Flow Meters and Primary Elements Product Data Sheet, 00813-0100-4484, March 2023.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | System reference accuracy at 8:1 flow turndown: +/-1.75% of flow rate for a conditioning element at beta 0.4, +/-1.95% at beta 0.50 and 0.65, +/-2.00% for a conventional plate and +/-1.80% for a calibrated Annubar; add 0.5% outside 2 to 8 in line sizes on the plate option |
| Output signal | 4-20 mA with HART digital signal from the 3051C transmitter; the platform also supports FOUNDATION Fieldbus and PROFIBUS PA |
| Power supply | Loop powered from the 3051C transmitter, 10.5 to 42.4 Vdc with no load |
| Diagnostics | Loop Integrity and Plugged Impulse Line diagnostics (code DA1) detect impulse line problems; Bluetooth configuration (BLE), backlit graphical display with totalizer (M6) and safety certification with proof testing (QT, T9) available |
| Measurement range | Line sizes 1/2 to 12 in (15 to 300 mm); element options are a conditioning orifice plate (C), a conventional orifice plate (P) or a Compact Annubar averaging pitot (A) |
| Application | Compact differential pressure flow measurement for gas, liquid and steam, installed between existing raised-face flanges and supplied as an assembled, leak-tested meter |
| Mounting | Primary element clamps between existing raised-face flanges with no spool piece; the complete assembly is leak tested before shipment |
| Material of construction | 316 stainless steel primary element and manifold |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer