Rosemount 3051CFP Integral Orifice Flow Meter
Purchase options
From$1,776.50
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Integral orifice flow meter for 1/2 to 1 1/2 in lines, combining a honed pipe section, self-centering orifice plate and 3051 DP transmitter to remove alignment errors.
Key features
- Integral orifice flow meter with a honed pipe section and self-centering orifice plate
- Line sizes 1/2, 1 and 1 1/2 in (15, 25 and 40 mm), with bore sizes from 0.010 to 1.100 in
- Flow reference accuracy from +/-1.75% of flow rate at 8:1 turndown for 0.500 to 1.000 in bores
- 316 SST body and orifice plate; fully assembled and leak tested before shipment
- 3051 transmitter platform: 4-20 mA with HART, or FOUNDATION Fieldbus and PROFIBUS PA
- Optional Loop Integrity and Plugged Impulse Line diagnostics, Bluetooth, backlit display, safety certification
Key specifications
- Accuracy
- Flow reference accuracy at 8:1 turndown: +/-1.75% for bores 0.500 to 1.000 in, +/-1.95% for 0.160 to under 0.500 in, +/-2.15% above 1.000 in and +/-3.00% below 0.160 in; 3051C total performance +/-0.14% of span
- Output signal
- 4-20 mA with HART digital signal as standard; FOUNDATION Fieldbus and PROFIBUS PA available on the 3051 transmitter platform
- Power supply
- Loop powered from the 3051 transmitter; long-term stability +/-0.2% of URL for ten years on ranges 2 to 5
- Diagnostics
- Optional Loop Integrity and Plugged Impulse Line diagnostics (code DA1) detect impulse line problems; Bluetooth configuration (BLE), backlit graphical display (M6) and safety certification with proof test (QT, T9) available
- Certifications
- Hazardous area approval codes for FM, CSA, ATEX and IECEx; safety instrumented system certification available with proof testing
- Measurement range
- Line sizes 1/2, 1 and 1 1/2 in (15, 25 and 40 mm); bore sizes from 0.010 to 1.100 in selected by line size
Small lines, where every misalignment is magnified
The Rosemount 3051CFP is an integral orifice flow meter: a precision honed pipe section, an orifice plate that centres itself, and a 3051 differential pressure transmitter bolted directly to it. It is built for half-inch, one-inch and inch-and-a-half lines, and it exists because of an uncomfortable fact about orifice measurement.
Why small lines are harder than large ones
Orifice flow depends on the bore and the pipe inside diameter, and the relationship is not linear. On a two-inch line a plate that sits half a millimetre off centre barely matters. On a half-inch line, the same offset is a meaningful fraction of the bore, and the error it introduces is multiplied into the flow reading. Pipe inside-diameter tolerance compounds it: a standard pipe's wall tolerance is a larger percentage of a small diameter, and the beta ratio silently shifts with it.
What the hardware does about it
The pipe section is honed to a known inside diameter rather than accepted as supplied, and the plate is self-centering in the body, so the alignment error is removed by the design instead of by careful installation. The meter arrives fully assembled and leak tested, which removes the field step where a plate gets installed backwards or a gasket gets pinched — two failures that are invisible until someone compares the reading to a tank.
Accuracy by bore size
Flow reference accuracy at 8:1 turndown is ±1.75% for bores from 0.500 to 1.000 in, ±1.95% from 0.160 to under 0.500 in, ±2.15% above 1.000 in, and ±3.00% below 0.160 in. The pattern is worth reading: the smaller the bore, the worse the achievable accuracy, because manufacturing tolerance and Reynolds number effects both bite harder. That is the honest cost of measuring a small flow.
Transmitter and options
The 3051 transmitter platform supplies 4-20 mA with HART as standard, with FOUNDATION Fieldbus and PROFIBUS PA available. Long-term stability is ±0.2% of URL for ten years on ranges 2 to 5, and total performance ±0.14% of span. Optional Loop Integrity and Plugged Impulse Line diagnostics watch the impulse lines themselves — the failure that reads as a plausible flow — and Bluetooth, a backlit graphical display, or safety certification with proof testing can be specified.
Where it fits
Chemical injection, additive dosing, small utility lines, pilot plants and anywhere a half-inch or one-inch flow needs to be measured with a DP cell and there is no room for a long straight run. The 316 stainless body and plate cover the usual services, with the standard approval codes for hazardous areas.
Manufacturer reference: Rosemount DP Flow Meters and Primary Elements Product Data Sheet, 00813-0100-4484, March 2023.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Flow reference accuracy at 8:1 turndown: +/-1.75% for bores 0.500 to 1.000 in, +/-1.95% for 0.160 to under 0.500 in, +/-2.15% above 1.000 in and +/-3.00% below 0.160 in; 3051C total performance +/-0.14% of span |
| Output signal | 4-20 mA with HART digital signal as standard; FOUNDATION Fieldbus and PROFIBUS PA available on the 3051 transmitter platform |
| Power supply | Loop powered from the 3051 transmitter; long-term stability +/-0.2% of URL for ten years on ranges 2 to 5 |
| Diagnostics | Optional Loop Integrity and Plugged Impulse Line diagnostics (code DA1) detect impulse line problems; Bluetooth configuration (BLE), backlit graphical display (M6) and safety certification with proof test (QT, T9) available |
| Certifications | Hazardous area approval codes for FM, CSA, ATEX and IECEx; safety instrumented system certification available with proof testing |
| Measurement range | Line sizes 1/2, 1 and 1 1/2 in (15, 25 and 40 mm); bore sizes from 0.010 to 1.100 in selected by line size |
| Application | Integral orifice flow measurement in small line sizes where plate centring and pipe inside-diameter variation would otherwise dominate the uncertainty |
| Mounting | Precision honed pipe section with a self-centering orifice plate, supplied fully assembled and leak tested for out-of-the-box installation |
| Material of construction | 316 stainless steel body (code F) and 316 stainless steel orifice plate (code S) |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer