Hygienic in-line gauge pressure transmitter to 300 psig with tri-clamp connections, 3-A/EHEDG approval and Ra < 15 micro-inch wetted surfaces.
Key features
- Hygienic in-line gauge pressure transmitter, -14.7 to 300 psi (-1.01 to 20.7 bar-g), 3-A and EHEDG approved
- Wetted surfaces mechanically polished and electropolished to Ra < 15 micro-inch (0.38 micrometre), free of voids and crevices
- Demonstrated SIP/CIP performance up to 302 F (150 C), with rapid and repeatable recovery rather than just temperature survival
- 100:1 rangeability with 0.065% of span reference accuracy on the high performance option (0.075% standard)
- 1-1/2 in. and 2 in. tri-clamp connections, or assembled to a Rosemount 1199 diaphragm seal with an SST transmitter flange
- 4-20 mA HART or FOUNDATION Fieldbus; special cleaning (P2), <1 ppm chlorine/fluorine cleaning (P3) and a wetted surface finish certificate available
Key specifications
- Accuracy
- Reference accuracy 0.065% of span with the high performance option (0.075% standard), with five and seven year stability depending on option. Accuracy is quoted per span, so a narrower calibrated span improves the practical figure
- Output signal
- 4-20 mA with digital signal based on HART, or FOUNDATION Fieldbus; AMS Suite: Intelligent Device Manager compatible, with Plantweb diagnostics options including power advisory HART diagnostics
- Diagnostics
- Wetted surfaces mechanically polished and then electropolished to Ra < 15 micro-inch (0.38 micrometre), which is the geometry 3-A and EHEDG approve - not the material grade alone. Conduit entry 1/2-14 NPT or M20 x 1.5
- Pressure range
- -14.7 to 300 psi (-1.01 to 20.7 bar-g) gauge, with 100:1 rangeability so one part number covers duties that would otherwise need several
- Variants
- Tri-clamp 1-1/2 in. (T32) and 2 in. (T42) with 316L SST diaphragm and housing, or assembled to a Rosemount 1199 diaphragm seal with an SST transmitter flange (B11). Options include P2 special cleaning, P3 cleaning for <1 ppm chlorine/fluorine, and a wetted surface finish certificate
- Application
- Food and beverage lines with clean-in-place, pharmaceutical and biotech process piping, dairy and brewing, and any service where the instrument is part of the hygienic envelope rather than bolted outside it
Hygienic is a surface, not a sensor
The Rosemount 3051HT is an in-line gauge pressure transmitter for hygienic service: -14.7 to 300 psi (-1.01 to 20.7 bar-g), tri-clamp connections, and a wetted path finished to Ra < 15 μ-in (0.38 μm) by mechanical polishing followed by electropolishing. It carries 3-A and EHEDG approval. The approval is the part worth understanding, because it is not awarded for the material grade — it is awarded for a geometry and a surface that can be cleaned.
Why the finish is the measurement's credibility
A hygienic transmitter is judged on what can grow on it. A machined surface with microscopic pits, a crevice where the diaphragm meets its housing, a thread in contact with product — each is a place where a cleaning cycle does not reach and where a biofilm survives to inoculate the next batch. The 3051HT's wetted surfaces are polished and then electropolished, and the stainless design is described as free of voids and crevices. That is what 3-A and EHEDG are inspecting: not whether the steel is 316L, but whether the shape gives a cleaning fluid and a rinse somewhere to go.
The claim that matters after every CIP cycle
Emerson's own wording is more careful than "withstands 150 °C": the transmitter demonstrates best-in-class performance during SIP/CIP for process temperatures up to 302 °F (150 °C), and it is built so it recovers rapidly and repeatably from those cycles. That distinction is the whole engineering problem. A transmitter that survives a steam cycle but shifts its zero afterwards is worse than one that fails, because the shift is invisible — the batch reads a plausible number that is no longer true, and it keeps doing so until the next calibration. The design effort here is in minimising temperature-induced error and in the repeatability of recovery, not in the maximum temperature on a datasheet.
Rangeability as a spares decision
Rangeability is 100:1, with reference accuracy of 0.065 percent of span on the high performance option (0.075 percent standard) and stability quoted at five and seven years depending on the option. A 100:1 turndown means one part number can cover a range of duties that would otherwise need three, which on a plant with many small hygienic lines is the difference between a shelf of spares and a stocked part. The accuracy figure is per span, so the practical accuracy improves as the calibrated span narrows — another reason the high turndown is worth having rather than merely quoting.
Connections and the documentation options
Process connections are 1½ in and 2 in tri-clamp, or the transmitter can be assembled to a Rosemount 1199 diaphragm seal with an SST transmitter flange for service where the diaphragm has to be remote from the electronics. Output is 4–20 mA with HART, or FOUNDATION Fieldbus. Among the options, three exist for audits rather than for process: P2 special cleaning, P3 cleaning for <1 ppm chlorine/fluorine, and a wetted surface finish certificate — the paperwork a food or pharmaceutical qualification asks for when it wants proof of the Ra rather than a statement in a datasheet.
Where it fits
Food and beverage lines with clean-in-place, pharmaceutical and biotech process piping, dairy and brewing, and any service where the instrument is part of the hygienic envelope rather than bolted to the outside of it. It is also the right choice where a conventional transmitter would need a diaphragm seal simply to present a cleanable face — the 3051HT presents one by construction.
Manufacturer reference: Rosemount 3051HT Hygienic Pressure Transmitter Product Data Sheet, ordering information and specifications.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Reference accuracy 0.065% of span with the high performance option (0.075% standard), with five and seven year stability depending on option. Accuracy is quoted per span, so a narrower calibrated span improves the practical figure |
| Output signal | 4-20 mA with digital signal based on HART, or FOUNDATION Fieldbus; AMS Suite: Intelligent Device Manager compatible, with Plantweb diagnostics options including power advisory HART diagnostics |
| Diagnostics | Wetted surfaces mechanically polished and then electropolished to Ra < 15 micro-inch (0.38 micrometre), which is the geometry 3-A and EHEDG approve - not the material grade alone. Conduit entry 1/2-14 NPT or M20 x 1.5 |
| Pressure range | -14.7 to 300 psi (-1.01 to 20.7 bar-g) gauge, with 100:1 rangeability so one part number covers duties that would otherwise need several |
| Variants | Tri-clamp 1-1/2 in. (T32) and 2 in. (T42) with 316L SST diaphragm and housing, or assembled to a Rosemount 1199 diaphragm seal with an SST transmitter flange (B11). Options include P2 special cleaning, P3 cleaning for <1 ppm chlorine/fluorine, and a wetted surface finish certificate |
| Application | Food and beverage lines with clean-in-place, pharmaceutical and biotech process piping, dairy and brewing, and any service where the instrument is part of the hygienic envelope rather than bolted outside it |
| Mounting | In-line tri-clamp connection to a sanitary ferrule, or remote via a 1199 diaphragm seal. The stainless design is free of voids and crevices so the wetted path can be cleaned and wiped down in place |
| Operating temperature (°C) | Demonstrated SIP/CIP performance for process temperatures up to 302 F (150 C), designed to minimise temperature induced error and to recover rapidly and repeatably after a cleaning or sterilisation cycle |