Overview
Electronic Remote Sensor level system pairing two sealed 3051SAL transmitters over a cable instead of a capillary, with +/-0.092% of DP span accuracy.
Key features
- Electronic Remote Sensor level system with two 3051SAL transmitters, each carrying a diaphragm seal at its tap
- Replaces a long fill-fluid capillary with a cable, removing its temperature error on tall vessels
- DP reference accuracy +/-0.092% of DP span on ranges 1 to 5 for both Ultra and Classic sensor classes
- Seal diaphragms in 316L SST, Alloy C-276, Alloy 400, Tantalum or gold-plated options
- Cable up to 500 ft (152 m) non-IS, 225 ft (68.6 m) intrinsically safe, 125 ft (38 m) armored
- 4-20 mA with HART on the 3051S platform; FOUNDATION Fieldbus and WirelessHART available
Key specifications
- Accuracy
- DP reference accuracy +/-0.092% of DP span on ranges 1 to 5 for both Ultra and Classic sensor classes, assuming two transmitters of identical range calibrated 0 to URL with the DP span at 10% of URL
- Output signal
- 4-20 mA with HART digital signal from the primary sensor; FOUNDATION Fieldbus and WirelessHART available
- Power supply
- Loop powered from the primary transmitter on the 3051S platform, 10.5 to 42.4 Vdc with no load
- Diagnostics
- Sensor module temperatures for both the primary (PHI) and secondary (PLO) sensor, plus the 3051S platform diagnostic suite
- Measurement range
- Level ranges 1 to 5 on the 3051S platform; the DP span is the difference between the two sensor readings
- Application
- Electronic Remote Sensor level measurement with two sealed 3051SAL transmitters, one at each tap, for tall vessels where a fill-fluid capillary is impractical
Two sealed sensors, one cable, for level in a tall vessel
The Rosemount 3051SAL ERS is the level version of the Electronic Remote Sensor system: two 3051SAL transmitters, each with its own diaphragm seal at a tap, communicating over a cable instead of a filled capillary. The primary sensor carries the loop; the secondary reports its own pressure. The difference between them is the level.
What it replaces, and why that matters on a column
A conventional sealed level measurement runs a fill-fluid capillary from the bottom tap up to the transmitter. On a tall column that capillary is long, exposed and temperature-sensitive: sun on one section and shade on another changes the fill volume, and the error appears as level. The ERS design puts a seal and a sensor at each tap and sends the reading digitally, so the fluid path is millimetres long at each end instead of metres between them.
Accuracy of the difference
For two 3051SAL level transmitters the ERS system gives ±0.092% of DP span on ranges 1 to 5, for both Ultra and Classic sensor classes — unlike the pressure versions, where the two classes differ. The figure assumes two transmitters of identical range, each calibrated over its full URL, with the DP span at 10% of that URL. That last condition is the one to check before quoting the number: a system measuring a small difference between two large pressures is limited by the sensors, not by the arithmetic.
Seals are still the interface
Each sensor keeps a diaphragm seal, so the same material logic applies as any sealed level measurement: 316L stainless steel, Alloy C-276, Alloy 400, Tantalum, or gold-plated diaphragms for hydrogen service. The difference is where the fill fluid lives — a short column behind a diaphragm at each tap, not a long capillary between the taps.
Cable and installation
The sensors connect over a dual twisted shielded pair, 22 AWG minimum for power and 24 AWG minimum for communication. Maximum total length is 500 ft (152 m) with Madison gray cable in non-intrinsically-safe installations, 225 ft (68.6 m) in IS, and 125 ft (38 m) with armored cable. Approval class therefore decides the cable before the cable decides anything else.
Where it fits
Distillation columns, tall storage tanks and reactors where a capillary would be long, hot, cold or subject to movement, and where the product is aggressive enough to need a seal at both taps. The two sensors also make it practical to measure level across a height that a single DP transmitter could not span with one capillary.
Manufacturer reference: Rosemount 3051S Electronic Remote Sensor System Reference Manual, 00809-0100-4804 Rev DB, and the Rosemount 3051S Series Product Data Sheet.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | DP reference accuracy +/-0.092% of DP span on ranges 1 to 5 for both Ultra and Classic sensor classes, assuming two transmitters of identical range calibrated 0 to URL with the DP span at 10% of URL |
| Output signal | 4-20 mA with HART digital signal from the primary sensor; FOUNDATION Fieldbus and WirelessHART available |
| Power supply | Loop powered from the primary transmitter on the 3051S platform, 10.5 to 42.4 Vdc with no load |
| Diagnostics | Sensor module temperatures for both the primary (PHI) and secondary (PLO) sensor, plus the 3051S platform diagnostic suite |
| Measurement range | Level ranges 1 to 5 on the 3051S platform; the DP span is the difference between the two sensor readings |
| Application | Electronic Remote Sensor level measurement with two sealed 3051SAL transmitters, one at each tap, for tall vessels where a fill-fluid capillary is impractical |
| Mounting | A sealed sensor at each pressure tap, connected by a dual twisted shielded pair (22 AWG power, 24 AWG communication); cable up to 500 ft (152 m) non-IS, 225 ft (68.6 m) IS and 125 ft (38 m) armored |
| Material of construction | Seal diaphragms in 316L SST, Alloy C-276, Alloy 400, Tantalum, gold-plated Alloy 400 or gold-plated 316L SST; sensor modules 316L SST |