Rosemount 3051SFC Compact Orifice Flow Meter
Purchase options
From$1,414.30
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Compact conditioning orifice flow meter that bolts between existing raised-face flanges and needs only two pipe diameters upstream and downstream, with DP, compensated and mass-flow measurement types.
Key features
- Conditioning orifice element: 2D upstream, 2D downstream
- Bolts between existing raised-face flanges
- Seven measurement types from DP only to fully compensated mass flow
- Calibrated reference accuracy ±0.80% of flow at 14:1 turndown
- Beta ratios 0.40, 0.50 and 0.65
- 4-20 mA HART with digital protocol and wireless options
Key specifications
- Measurement principle
- Differential pressure across a conditioning orifice plate; beta ratios 0.40, 0.50 and 0.65; 2D upstream and 2D downstream straight run
- Accuracy
- ±0.80% of flow rate at 14:1 turndown on calibrated ranges 2-3; ±1.55% standard; Range 1 adds up to 0.9% uncertainty
- Process temperature
- Set by the flange rating and transmitter option; remote mount for hot process lines
- Process connection
- Bolts between existing raised-face flanges; compact spool design with no impulse tubing
- Enclosure rating
- IP66/IP67 with aluminium or stainless steel housing
- Output signal
- 4-20 mA HART; FOUNDATION Fieldbus, PROFIBUS PA and WirelessHART available on the 3051S platform
What the 3051SFC is
A compact differential pressure flow meter built around a conditioning orifice plate. The plate sits in a short spool that bolts between two existing raised-face flanges, so the meter joins the line without cutting a long straight run out of the pipework.
Why the conditioning element matters
A plain orifice needs a long approach to settle the flow profile; the conditioning plate does that inside the meter body, so the installation can sit about two pipe diameters from an upstream disturbance and two from the downstream one. On a skid or a plant retrofit that is often the difference between measuring the line and not measuring it.
Measurement types
The meter is ordered as one of seven measurement types: differential pressure alone, differential pressure with temperature compensation, or the fully compensated form that reads differential pressure, static pressure and temperature together for mass and energy flow. Volumetric flow is the base output; the compensated builds add the density terms themselves instead of relying on a fixed assumption.
Accuracy you can state to a customer
Calibrated builds in ranges 2 and 3 are rated at ±0.80 % of flow rate across a 14:1 turndown; the standard build is ±1.55 %. Range 1 meters carry an additional uncertainty of up to 0.9 %, which is worth saying before the quote rather than after commissioning.
Choosing a beta ratio
Beta ratios of 0.40, 0.50 and 0.65 cover the usual trade-off: a smaller beta keeps permanent pressure loss down and a larger one buys signal at low flow. The bore follows from the beta and the pipe inside diameter, so the pipe ID has to be measured rather than assumed.
Installation notes
The plate is centred by the flange bolts, the transmitter mounts directly on the meter body, and the assembly needs no impulse tubing on the compact design. For steam and hot process lines the transmitter can be ordered remote.
Manufacturer reference: Emerson document 00813-0100-4485.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Differential pressure across a conditioning orifice plate; beta ratios 0.40, 0.50 and 0.65; 2D upstream and 2D downstream straight run |
| Accuracy | ±0.80% of flow rate at 14:1 turndown on calibrated ranges 2-3; ±1.55% standard; Range 1 adds up to 0.9% uncertainty |
| Process temperature | Set by the flange rating and transmitter option; remote mount for hot process lines |
| Process connection | Bolts between existing raised-face flanges; compact spool design with no impulse tubing |
| Enclosure rating | IP66/IP67 with aluminium or stainless steel housing |
| Output signal | 4-20 mA HART; FOUNDATION Fieldbus, PROFIBUS PA and WirelessHART available on the 3051S platform |
| Power supply | Two-wire, loop powered |
| Wetted materials | 316L stainless steel orifice plate and spool; alternative materials per model code |
| Diagnostics | Transmitter diagnostics over HART, with flow verification available on the 3051S platform |
| Certifications | Hazardous-area approvals and custody-transfer options per model code; see the data sheet for the selected certification |