Overview
Integral orifice flow meter with the element in a precision honed pipe section, built for small line sizes and shipped as one assembled spool with the 3051S transmitter mounted.
Key features
- Integral orifice element in a precision honed pipe section
- Two diameters upstream and downstream straight run
- Built for small line sizes where a wafer element is awkward
- Shipped as one assembled, leak-tested spool
- 3051S transmitter: 4-20 mA HART, digital protocols and wireless
- Reference accuracy stated per bore and range in the data sheet
Key specifications
- Measurement principle
- Integral orifice in a precision honed pipe section; differential pressure is converted to flow
- Accuracy
- Reference accuracy is stated per bore and range in the DP Flow data sheet; calibrated builds reach about ±0.8% of flow rate at 14:1 turndown
- Process temperature
- Set by the flange rating and transmitter option; remote mount for hot process lines
- Process connection
- Flanged spool from 1/2 in line size; element and pipe section are one machined assembly
- Enclosure rating
- IP66/IP67 with aluminium or stainless steel housing
- Output signal
- 4-20 mA HART; FOUNDATION Fieldbus, PROFIBUS PA and WirelessHART available on the 3051S platform
What the 3051SFP is
An integral orifice flow meter for small lines. Instead of a plate clamped between two flanges, the orifice sits in a short, precision honed pipe section that is machined as one piece and shipped with the transmitter already mounted. The result is a meter that installs like a spool: two flange joints, no impulse tubing, no separate centring step.
Where it earns its place
On 1/2 in to 2 in lines a wafter plate and its carrier can be more trouble than the measurement is worth — the bore is tiny, the tolerance on the pipe inside diameter dominates the uncertainty, and a rough pipe wall spoils the profile. The honed section removes that variable, which is why the integral orifice family is the one usually specified for small-line steam, gas and liquid service.
Straight run
The meter asks for about two pipe diameters upstream and two downstream from most disturbances, so it fits where a conventional orifice would need a long approach that the plant does not have.
Transmitter and output
The 3051S transmitter mounts directly on the element, or remotely where the line runs hot. Output is 4-20 mA with HART as standard, with FOUNDATION Fieldbus, PROFIBUS PA and WirelessHART available, and the compensated builds add static pressure and temperature to report mass and energy flow rather than assumed-density volumetric flow.
Ordering notes
The part number fixes the line size, bore, element material, flange rating and transmitter option. Bore and beta follow from the pipe inside diameter and the expected flow range, so those two numbers come before the model code, not after.
Manufacturer reference: Emerson document 00813-0100-4485.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Integral orifice in a precision honed pipe section; differential pressure is converted to flow |
| Accuracy | Reference accuracy is stated per bore and range in the DP Flow data sheet; calibrated builds reach about ±0.8% of flow rate at 14:1 turndown |
| Process temperature | Set by the flange rating and transmitter option; remote mount for hot process lines |
| Process connection | Flanged spool from 1/2 in line size; element and pipe section are one machined assembly |
| Enclosure rating | IP66/IP67 with aluminium or stainless steel housing |
| Output signal | 4-20 mA HART; FOUNDATION Fieldbus, PROFIBUS PA and WirelessHART available on the 3051S platform |
| Power supply | Two-wire, loop powered |
| Wetted materials | 316L stainless steel pipe section and orifice; alternative materials per model code |
| Diagnostics | Transmitter diagnostics over HART, with flow verification available on the 3051S platform |
| Certifications | Hazardous-area approvals per model code, including intrinsically safe and explosion-proof options |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer