Overview
In-line transmitter screwed straight into the process for gauge or absolute pressure. Spans run from 5 psi to 20 000 psi, reference accuracy is 0.04 % of span, and zero drift is held to 0.2 % of URL over ten years. Output options are 4-20 mA HART, FOUNDATION Fieldbus, PROFIBUS PA, WirelessHART or low-power 1-5 V.
Key features
- In-line body that mounts straight on the process, without impulse tubing
- Gauge or absolute measurement from 5 psi up to 20 000 psi
- 0.04 % span reference accuracy, 0.14 % installed total performance
- Zero drift held to 0.2 % of URL over ten years
- HART 5/7, FOUNDATION Fieldbus, PROFIBUS PA, WirelessHART or 1-5 V low power
- SIL 2/3 (IEC 61508) with 4X and IP66/IP67 enclosure options
Key specifications
- Measurement principle
- Piezoresistive in-line sensor for gauge and absolute pressure
- Accuracy
- ±0.04 % of span reference accuracy; ±0.14 % of span installed total performance
- Process temperature
- -46 to 121 C (-50 to 250 F) depending on fill fluid
- Pressure rating
- Ranges 1-6; up to 20 000 psi (1379 bar) on range 6
- Process connection
- 1/2-14 NPT standard; RC 1/2, 1/4 NPT and hygienic options
- Enclosure rating
- NEMA 4X / IP65, IP66, IP67, IP68
What this transmitter is
The 3051T is the in-line member of Emerson's 3051 family. There is no flange: the sensor ends in a threaded connection, so the unit screws directly onto the pipe or vessel and no impulse line runs between the process and the electronics.
Pressure range
- Gauge: -14.7 to 30 psi up to -14.7 to 10 000 psi, with a 20 000 psi upper-range option.
- Absolute: 0 to 30 psia up to 0 to 20 000 psia.
- Reference accuracy 0.04 % of span; installed total performance 0.14 %.
Mounting and connection
The standard process connection is 1/2-14 NPT, with RC 1/2, 1/4 NPT and hygienic versions available. The housing rotates on the neck, so the conduit entry can be aimed after the unit is in place, and a bracket is offered for pipe or panel mounting.
Electronics and approvals
Output is chosen at order time: 4-20 mA with HART revision 5 or 7, FOUNDATION Fieldbus, PROFIBUS PA, WirelessHART, or a 1-5 V low-power circuit. SIL 2/3 certification to IEC 61508 is available, together with explosion-proof and intrinsically safe approvals.
Choosing this build
The groups below carry the model variant, range, connection, housing and output. Selecting them in order assembles the part number, and each group lists the combinations it excludes.
Manufacturer reference: Emerson document 00813-0100-4001.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Piezoresistive in-line sensor for gauge and absolute pressure |
| Accuracy | ±0.04 % of span reference accuracy; ±0.14 % of span installed total performance |
| Process temperature | -46 to 121 C (-50 to 250 F) depending on fill fluid |
| Pressure rating | Ranges 1-6; up to 20 000 psi (1379 bar) on range 6 |
| Process connection | 1/2-14 NPT standard; RC 1/2, 1/4 NPT and hygienic options |
| Enclosure rating | NEMA 4X / IP65, IP66, IP67, IP68 |
| Output signal | 4-20 mA HART (rev 5/7), FOUNDATION Fieldbus, PROFIBUS PA, WirelessHART, 1-5 V low power |
| Power supply | 10.5 to 42.4 Vdc (HART, loop powered) |
| Wetted materials | 316L stainless steel, Alloy C-276, tantalum and gold-plated options |
| Diagnostics | Loop integrity and plugged impulse line detection (option DA1) |
| Certifications | SIL 2/3 (IEC 61508); explosion-proof, flameproof and intrinsically safe options |
| Pressure range | -14.7 to 30 psi up to 0 to 20 000 psia depending on range code |