Overview
Dual-input temperature transmitter for critical loops. It accepts RTD, thermocouple, mV and ohm inputs, holds accuracy to ±0.1 C on Pt100, and offers sensor backup, hot backup and drift alert so the loop keeps measuring when a sensor starts to fail.
Key features
- Two independent sensor channels in one transmitter
- RTD, thermocouple, millivolt, ohm and potentiometer inputs
- Accuracy to ±0.1 C on Pt100, declared per sensor type
- Sensor backup, hot backup and drift alert on dual-sensor duty
- 4-20 mA HART 5/7, FOUNDATION Fieldbus or PROFIBUS PA output
- SIL 2/3 (IEC 61508) with head, rail and field mounting options
Key specifications
- Measurement principle
- Dual-input RTD, thermocouple, millivolt, ohm and potentiometer measurement
- Accuracy
- ±0.1 C on Pt100 input; stated per sensor type
- Process temperature
- Sensor dependent; transmitter ambient -40 to 85 C (-40 to 185 F)
- Process connection
- Sensor head, DIN rail or field housing; sensor connection by terminal block
- Enclosure rating
- IP66 / IP67 on field-mount housing
- Output signal
- 4-20 mA HART (rev 5/7), FOUNDATION Fieldbus or PROFIBUS PA
What this transmitter is
The 3144P is the dual-input temperature transmitter in Emerson's range. Two independent sensor channels feed one 4-20 mA loop, so the instrument can measure a true differential, average two points, or hold one sensor in reserve while the other runs.
Inputs and accuracy
- Accepts RTD (Pt100, Pt200, Pt500, Pt1000, Ni120), thermocouples, millivolt, ohm and potentiometer inputs.
- Accuracy to ±0.1 C on a Pt100 input, stated per sensor type rather than as one headline figure.
- Two sensor channels with hot backup and sensor-drift alert.
Diagnostics
Drift alert compares the two sensors and flags the one that has moved, so a slow failure is caught before the loop trips. Open-circuit and short detection, plus a transmitter status flag, arrive over HART with the process value.
Mounting and housing
Head-mount, rail-mount and field-mount versions share the same electronics. The head-mount unit lives inside the sensor connection head, the rail unit sits in the panel, and the field version carries its own IP66/IP67 housing.
Output and approvals
Output is 4-20 mA with HART revision 5 or 7, FOUNDATION Fieldbus or PROFIBUS PA. SIL 2/3 certification to IEC 61508 is available, with explosion-proof and intrinsically safe approvals.
Manufacturer reference: Emerson document 00813-0100-4021.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Dual-input RTD, thermocouple, millivolt, ohm and potentiometer measurement |
| Accuracy | ±0.1 C on Pt100 input; stated per sensor type |
| Process temperature | Sensor dependent; transmitter ambient -40 to 85 C (-40 to 185 F) |
| Process connection | Sensor head, DIN rail or field housing; sensor connection by terminal block |
| Enclosure rating | IP66 / IP67 on field-mount housing |
| Output signal | 4-20 mA HART (rev 5/7), FOUNDATION Fieldbus or PROFIBUS PA |
| Power supply | 12 to 42.4 Vdc (HART, loop powered) |
| Wetted materials | Not wetted — mounts inside the sensor head or panel |
| Diagnostics | Sensor drift alert, open-circuit and short detection, transmitter status flag |
| Certifications | SIL 2/3 (IEC 61508); explosion-proof and intrinsically safe options |