Rosemount 3144S Temperature Transmitter
Purchase options
From$867.44
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Temperature transmitter with 0.05 C accuracy, 20-year stability, dual input, Bluetooth and X-well non-intrusive measurement to 650 C.
Key features
- HART 4-20 mA temperature transmitter with 0.05 C accuracy, 20-year stability and dual 4-wire sensor input
- Rosemount X-well technology measures the pipe surface and a secondary temperature and computes the process temperature with an in-transmitter thermal conductivity algorithm, so no thermowell and no process penetration are needed
- X-well reaches 1202 F (650 C) on the extended range, which must be remote mounted and carries industry standard accuracy, while the direct mounted standard range covers -58 to 572 F (-50 to 300 C) with industry leading accuracy
- The pipe mount material caps the temperature: 316 stainless stops at 842 F (450 C) and Alloy 625 is needed for the full 650 C
- ReadyConnect configures the sensor at the push of a button by detecting its type, and Bluetooth moves configuration and troubleshooting off the device at up to ten times the traditional speed
- Loop Integrity continuously monitors the electrical loop for corroded terminals and moisture paths that appear as a slow plausible drift rather than a fault, and the diagnostic log stores up to 100 events
Key specifications
- Accuracy
- 0.05 C. Rosemount X-well carries a performance class per range code: the standard range (TR1, -58 to 572 F / -50 to 300 C, direct mount) is industry leading, while the extended range (TR2, -76 to 1202 F / -60 to 650 C, remote mount) is industry standard
- Output signal
- 4-20 mA with digital signal based on HART protocol, with dual 4-wire sensor input and a local display that shows the process measurement and a second measurement side by side
- Diagnostics
- Complete diagnostic coverage from sensor to control room: sensor health diagnostics, RTD measurement protection, process alerts with min/max tracking, and Loop Integrity, which monitors the electrical loop continuously for corroded terminals and moisture paths. Those faults are invisible on a 4-wire RTD because the loop current is not the sensor current, and they appear as a slow plausible drift rather than a fault. Diagnostic log stores up to 100 events. ReadyConnect configures the sensor at the push of a button by detecting its type, and Bluetooth moves configuration and troubleshooting off the device
- Pressure range
- Not applicable with Rosemount X-well, which clamps to the outside of the pipe and creates no process penetration and no pressure boundary. The thermowell versions are rated by the well selected with the sensor
- Application
- Process temperature on reactors, columns, heat exchangers and pipelines; dual-sensor applications needing a differential or a redundant pair; and lines where a thermowell is unwanted or impossible, such as small bore, hygienic, high pressure, or a line that cannot be shut down to install a well
- Operating temperature (°C)
- X-well process range -58 to 572 F (-50 to 300 C) direct mount, or -76 to 1202 F (-60 to 650 C) remote mount. The pipe mount material caps it independently: 316 stainless to 842 F (450 C), Alloy 625 to 1202 F (650 C)
Two things changed: where the sensor is, and how you talk to it
The Rosemount 3144S is a HART 4–20 mA temperature transmitter with 0.05 °C accuracy, 20-year stability, dual 4-wire sensor input, Bluetooth connectivity, ReadyConnect sensor configuration, complete diagnostics from sensor to control room — and, if you order it that way, X-well technology: non-intrusive process temperature measurement up to 1202 °F (650 °C) with no thermowell at all.
The local display says a lot about the instrument: on a two-sensor configuration it shows the process reading and a second measurement side by side, which is the dual-input architecture made visible rather than hidden in a manual.
X-well measures a pipe, not a fluid
X-well does not put a sensor in the process. It clamps to the outside of the pipe, measures the pipe surface temperature and a secondary temperature, and computes the process temperature with an in-transmitter thermal conductivity algorithm using the thermal properties of the installation and the pipe.
Read that as: it is a calculation, and the pipe is an input to it. That has three consequences you can see in the ordering tables.
One — the pipe dimensions are a specification, not a label. The pipe size code runs from ½ in (DN15, 22 mm) up to at least 6 in (DN150) in fine steps, and the pipe mount is ordered either as a small-pipe mount for ½ to 1½ in, or a universal mount covering 2 to 60 in (DN50 to DN1500). Those numbers tell the algorithm the wall it is calculating across. They are also why the factory asks for the specific pipe characteristics at order time: an X-well configured for the wrong pipe is an instrument computing the right answer to the wrong question.
Two — the temperature range code decides the accuracy class. The standard range (TR1) covers −58 to +572 °F (−50 to +300 °C), mounts directly, and is listed with industry leading performance. The extended range (TR2) reaches −76 to +1202 °F (−60 to +650 °C), must be remote mounted — with connection head, cable glands and remote cable — and is listed with industry standard performance. So the 650 °C capability is bought with distance and with a step down in accuracy class. If your process is inside 300 °C, taking TR1 is not a compromise, it is the better measurement.
Three — the mount material caps the temperature. The 316 stainless pipe mount is rated to +842 °F (+450 °C); the Alloy 625 mount reaches +1202 °F (+650 °C). A specification written as "X-well, 650 °C" with a stainless mount is a 450 °C assembly. Say "Alloy 625 mount" if the number matters.
What removing the thermowell actually removes
The reasons to want this are engineering reasons, not conveniences:
A thermowell is a hole in a pressure boundary, closed by a weld or a thread, holding a cantilevered tube in a flowing stream. It introduces a leak path, a wake-frequency design problem in fast flow, a pressure-retaining weld that has to be inspected, an insertion length that has to be right, and on a small line, a well that is bigger than the pipe. Remove it and every one of those disappears, along with the isolation valves and the shutdown needed to service the sensor.
What it costs is response. A wall-mounted calculation responds to the pipe's thermal mass, not to the fluid directly, so it is slower and it depends on insulation and ambient conditions in a way an immersed sensor does not. That is the honest trade, and it is why the direct-mount TR1 with the leading accuracy is the right pick whenever the temperature allows it.
0.05 °C is the headline; twenty years is the saving
The accuracy figure is what gets quoted. The 20-year stability is what changes the maintenance plan: a transmitter that does not drift over twenty years is one whose recalibration interval is a decision about the process rather than a hedge against the electronics. Combine it with the diagnostic logging of up to 100 events and the loop has a history — what tripped, when, what the sensor reported — instead of a calibration sticker and someone's memory.
Loop Integrity is the diagnostic worth naming. It monitors the electrical loop continuously for problems that affect the measurement: a corroded terminal, a loose connection, a moisture path adding resistance. Those faults are invisible on a 4-wire RTD because the loop current is not the sensor current, and they are exactly the failures that appear as a slow, plausible drift rather than as a fault.
Commissioning without standing at the device
ReadyConnect configures the sensor at the push of a button, detecting the sensor type automatically — which removes the most common commissioning error in temperature measurement, a transmitter configured for a 3-wire Pt100 that is wired to a 4-wire one. Bluetooth connectivity moves configuration, service and troubleshooting off the device and onto a phone or tablet, quoted at up to ten times faster than the traditional route, and it matters most in the places these transmitters live: on top of a tank, inside a bundle, or behind a steam header.
Where it fits
Process temperature on reactors, columns, heat exchangers and pipelines; dual-sensor applications where a differential or a redundant pair matters; and lines where a thermowell is unwanted or impossible — small bore, hygienic, high-pressure, or simply too expensive to shut down to install. For the non-intrusive cases, choose the range code from the temperature, the mount material from the temperature too, and the pipe code from the actual pipe — and keep the pipe data with the instrument record, because the calculation depends on it.
Manufacturer reference: Rosemount 3144S Temperature Transmitter Product Data Sheet and Configuration Data Sheet for accuracy and stability, the measurement functionality codes, X-well ordering, and diagnostics.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | 0.05 C. Rosemount X-well carries a performance class per range code: the standard range (TR1, -58 to 572 F / -50 to 300 C, direct mount) is industry leading, while the extended range (TR2, -76 to 1202 F / -60 to 650 C, remote mount) is industry standard |
| Output signal | 4-20 mA with digital signal based on HART protocol, with dual 4-wire sensor input and a local display that shows the process measurement and a second measurement side by side |
| Diagnostics | Complete diagnostic coverage from sensor to control room: sensor health diagnostics, RTD measurement protection, process alerts with min/max tracking, and Loop Integrity, which monitors the electrical loop continuously for corroded terminals and moisture paths. Those faults are invisible on a 4-wire RTD because the loop current is not the sensor current, and they appear as a slow plausible drift rather than a fault. Diagnostic log stores up to 100 events. ReadyConnect configures the sensor at the push of a button by detecting its type, and Bluetooth moves configuration and troubleshooting off the device |
| Pressure range | Not applicable with Rosemount X-well, which clamps to the outside of the pipe and creates no process penetration and no pressure boundary. The thermowell versions are rated by the well selected with the sensor |
| Application | Process temperature on reactors, columns, heat exchangers and pipelines; dual-sensor applications needing a differential or a redundant pair; and lines where a thermowell is unwanted or impossible, such as small bore, hygienic, high pressure, or a line that cannot be shut down to install a well |
| Operating temperature (°C) | X-well process range -58 to 572 F (-50 to 300 C) direct mount, or -76 to 1202 F (-60 to 650 C) remote mount. The pipe mount material caps it independently: 316 stainless to 842 F (450 C), Alloy 625 to 1202 F (650 C) |
| Sensor | X-well measures the pipe surface temperature and a secondary temperature, then computes the process temperature with an in-transmitter thermal conductivity algorithm using the thermal properties of the installation and the pipe. The pipe size code (from 1/2 in / DN15 / 22 mm up to 6 in / DN150 and beyond) is an input to that calculation, not a label, which is why the factory asks for the pipe characteristics |
| Stability | 20-year stability. The transmitter is specified not to drift over twenty years, which makes the recalibration interval a decision about the process rather than a hedge against the electronics |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer