Rosemount 326L Probes
Purchase options
From$27.34
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Guide rod probes for the 326L guided wave radar transmitter: seven lengths from 150 to 2000 mm, 316L polished to Ra 0.8 micrometre, IP69K.
Key features
- Guide rod probes for the Rosemount 326L guided wave radar level transmitter, in seven lengths from 5.9 in (150 mm) to 78.7 in (2000 mm)
- Polished to Ra < 32 micro-inch (0.8 micrometre) so the surface cannot harbour biofilm that a caustic wash will not remove
- IP69K on the transmitter: rated for high-pressure high-temperature jet cleaning, which is the food line washdown case, not just a wet environment
- Length is a vessel measurement, not a range measurement - the probe must not touch the tank bottom or walls and lateral clearance grows with length
- Probes may be shortened, but the transmitter does not support under 5.91 in (150 mm) and tank adjustment is impossible below 10.24 in (260 mm)
- Q8 adds a material traceability certificate and must be ordered with the probe; 316L SST with EPDM and PEEK wetted parts, 150 C, up to 2000 mm
Key specifications
- Accuracy
- The probe sets the path the radar pulse travels; measurement performance belongs to the 326L transmitter. A probe that is the wrong length or touching the tank bottom is the most common cause of a level reading that looks plausible and is offset
- Output signal
- Not applicable - the probe is a passive 316L rod; the transmitter generates and interprets the pulse
- Diagnostics
- Ra < 0.8 micrometre is a hygienic requirement rather than a finish preference: biofilm establishes in a roughness pattern that a caustic wash does not reliably clear, so a correct-length probe with the wrong finish reintroduces the problem the line was designed away from. IP69K covers high-pressure high-temperature jet cleaning, not merely a wet environment
- Pressure range
- Not stated as a probe rating: the probe is the waveguide inside the vessel and the process connection seals at the adapter. Process temperature to 302 F (150 C) and measuring range to 78.7 in (2000 mm)
- Variants
- Seven lengths: FB-2015 5.9 in (150 mm), FB-2030 11.8 in (300 mm), FB-2050 19.7 in (500 mm), FB-2070 27.6 in (700 mm), FB-2100 39.4 in (1000 mm), FB-2150 59.1 in (1500 mm), FB-2200 78.7 in (2000 mm). Add Q8 for a material traceability certificate
- Application
- Guide rod probe for the Rosemount 326L guided wave radar level transmitter in food and beverage, as a replacement or for a second vessel of a different height
Seven lengths, one transmitter, and a surface finish that is a regulatory requirement
These are the guide rod probes for the Rosemount 326L guided wave radar level transmitter — the stainless rod that the radar pulse travels along and reflects from the product surface. They are supplied in seven discrete lengths and polished to a hygienic finish, and both of those facts are more consequential than a spare-part listing usually is.
The lengths, and how to pick one
| Length | Part number |
|---|---|
| 5.9 in (150 mm) | FB-2015 |
| 11.8 in (300 mm) | FB-2030 |
| 19.7 in (500 mm) | FB-2050 |
| 27.6 in (700 mm) | FB-2070 |
| 39.4 in (1000 mm) | FB-2100 |
| 59.1 in (1500 mm) | FB-2150 |
| 78.7 in (2000 mm) | FB-2200 |
The choice is a vessel measurement, not a range measurement. The probe has to reach far enough to cover the level you need to see, and it must not touch the bottom or the walls — the installation instructions are explicit that the probe cannot contact the tank wall or structures, and that the minimum lateral distance grows with probe length because a long rod deflects. So the correct length comes from the tank drawing, with a margin at the bottom, rather than from matching a span figure.
Cutting is allowed, and it changes the instrument
The manual does describe shortening a probe to suit the vessel, which is useful when a longer standard length is what is on the shelf. Two limits bound it: the transmitter does not support probes shorter than 5.91 in (150 mm), and tank adjustment is not possible below 10.24 in (260 mm). Both mean the shortest probe in the table is a shallow-vessel part and not a universal blank. Any cut also moves the end of the probe, so the measurement has to be re-configured afterwards — a shortened probe with the old configuration reports a level that is wrong by the amount removed.
Ra and IP69K are the hygienic argument, in that order
Every probe is polished to Ra < 32 µin (0.8 µm), and the transmitter is rated IP69K. Those two numbers are what make this a food-and-beverage instrument rather than a stainless instrument:
- The finish is where biofilm lives. A caustic wash removes soil from a smooth surface; it does not reliably remove a layer of organisms that has established itself in an 80 µin scratch pattern. Hygienic design therefore specifies roughness, not just material, and the requirement survives into the spare part — a replacement probe that is the right length but the wrong finish reintroduces the problem the line was designed away from.
- IP69K is the washdown case, not the weather case. It covers high-pressure, high-temperature jet cleaning, which is what a food line does between runs. IP67 would survive a wet environment; it would not survive the cleaning procedure.
The certificate option
Q8 adds a material traceability certificate and is appended to the part number (FB-2015Q8). In food and beverage this is frequently a customer or audit requirement rather than a preference, and it carries additional lead time — so it belongs on the original order. A probe bought later without it cannot be retroactively certified, and the paperwork is the point.
Where it fits
Replacing a damaged or shortened probe on an existing 326L installation, or fitting a second vessel with a different height. Wetted materials are 316L stainless polished to Ra < 0.8 µm, with EPDM and PEEK, process temperature to 302 °F (150 °C) and measuring range to 78.7 in (2000 mm). Match the length to the vessel, keep the finish intact, and order the certificate with the probe if the application needs one.
Manufacturer reference: Rosemount 326L Level Transmitter Product Data Sheet 00813-0100-4326, probes, O-rings and accessories; 326L reference manual for probe length limits and installation clearances.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | The probe sets the path the radar pulse travels; measurement performance belongs to the 326L transmitter. A probe that is the wrong length or touching the tank bottom is the most common cause of a level reading that looks plausible and is offset |
| Output signal | Not applicable - the probe is a passive 316L rod; the transmitter generates and interprets the pulse |
| Diagnostics | Ra < 0.8 micrometre is a hygienic requirement rather than a finish preference: biofilm establishes in a roughness pattern that a caustic wash does not reliably clear, so a correct-length probe with the wrong finish reintroduces the problem the line was designed away from. IP69K covers high-pressure high-temperature jet cleaning, not merely a wet environment |
| Pressure range | Not stated as a probe rating: the probe is the waveguide inside the vessel and the process connection seals at the adapter. Process temperature to 302 F (150 C) and measuring range to 78.7 in (2000 mm) |
| Variants | Seven lengths: FB-2015 5.9 in (150 mm), FB-2030 11.8 in (300 mm), FB-2050 19.7 in (500 mm), FB-2070 27.6 in (700 mm), FB-2100 39.4 in (1000 mm), FB-2150 59.1 in (1500 mm), FB-2200 78.7 in (2000 mm). Add Q8 for a material traceability certificate |
| Application | Guide rod probe for the Rosemount 326L guided wave radar level transmitter in food and beverage, as a replacement or for a second vessel of a different height |
| Mounting | Screwed into the transmitter or hygienic adapter and inserted into the vessel. The probe must not contact the tank wall or structures, and minimum lateral distance grows with probe length because a long rod deflects. Probes may be shortened, but not below 5.91 in (150 mm), and tank adjustment is impossible below 10.24 in (260 mm) |
| Operating temperature (°C) | Process temperature up to 302 F (150 C). Wetted materials 316L SST polished to Ra < 32 micro-inch (0.8 micrometre), EPDM and PEEK |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer