Rosemount 33185-01 Mounting Adapter
No product images are published for this product yet.
Purchase options
$64.08
- Availability
- Call for availability Originalx
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Submersion mounting adapter, 3 in long, with a 1 in MNPT connection and a PEEK body, for holding a pH or ORP sensor at a fixed depth in a tank or channel.
Key features
- Submersion mounting adapter for sensors with a 1 in MNPT thread
- 3 in length sets the immersion depth
- 1 in MNPT process connection into the vessel
- PEEK body for chemical resistance and no metal path
- Fits pH/ORP sensors in the 389, 3500 and 3900 families
- Keeps the sensor at a fixed depth through fill, drain and cleaning cycles
Key specifications
- Line size range
- 3 in overall length, which sets the immersion depth of the sensor
- Process connection
- 1 in MNPT thread into the vessel
- Wetted materials
- PEEK body
- Sensor connection
- 1 in MNPT sensor thread, as used by the 389, 3500 and 3900 pH/ORP families
- Application
- Submersion mounting for a pH or ORP sensor in a tank, sump, basin or open channel
- Mounting
- Screws into a 1 in MNPT fitting; the sensor hangs below the liquid line and stays at a fixed depth through fill, drain and cleaning
What the 33185-01 is
A submersion mounting adapter: the piece of hardware that lets a sensor hang into a tank, sump or open channel instead of sitting in a pipe tee. It screws into a 1 in MNPT fitting on the vessel and holds the sensor at a fixed depth, with the body moulded in PEEK so the mounting itself survives the same chemistry the sensor is measuring.
Why the adapter is not a detail
A sensor in a tank needs to sit at a depth where the liquid actually moves and where the measuring surface stays submerged, and it needs to stay there while the tank is filled, drained and cleaned. Bracket-and-clamp lash-ups drift; a threaded adapter fixes the position and keeps the sensor's own thread out of the process.
What decides the fit
The three things that matter are the thread into the vessel (1 in MNPT), the length that sets how deep the sensor sits (3 in), and the material (PEEK, chosen for chemical resistance and for not introducing a metal path into a measuring circuit). The sensor side takes the 1 in MNPT thread used by the pH/ORP sensors in the 389, 3500 and 3900 families.
Where it fits
Tanks, sumps, basins and open channels in water, wastewater and chemical service where a pH or ORP sensor is immersed rather than piped.
Manufacturer reference: Rosemount liquid analysis accessory range, submersion mounting adapters.
Specifications
| Attribute | Value |
|---|---|
| Line size range | 3 in overall length, which sets the immersion depth of the sensor |
| Process connection | 1 in MNPT thread into the vessel |
| Wetted materials | PEEK body |
| Sensor connection | 1 in MNPT sensor thread, as used by the 389, 3500 and 3900 pH/ORP families |
| Application | Submersion mounting for a pH or ORP sensor in a tank, sump, basin or open channel |
| Mounting | Screws into a 1 in MNPT fitting; the sensor hangs below the liquid line and stays at a fixed depth through fill, drain and cleaning |
Documents
No documents are published for this product yet.
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer