Overview

SIL 2 (SIL 3 capable) 80 GHz radar for level and overfill prevention, up to 30 m, with remote proof-testing from the control room.

Key features

  • 80 GHz fast-sweep FMCW radar level transmitter, SIL 2 certified to IEC 61508 and SIL 3 capable, for overfill prevention, dry-run prevention and level range monitoring
  • Smart Meter Verification carries out remote verification and proof-testing from the control room at any time without interrupting the process, which is what makes a long proof-test interval achievable rather than merely promised
  • Maximum range 98 ft (30 m) with +/-1 mm ultra accuracy or +/-2 mm standard, and 4-20 mA with HART 7
  • Three antennas for three problems: a lens antenna for small process fittings, a process seal antenna with PTFE wetted parts, and a bracket mounted ATAP lens for open air applications
  • The solids range is set by the product: 33 ft for light powder with a dielectric constant of 1.2 up to 98 ft for heavy powder, and the 3/4 in threaded lens antenna is limited to 49 ft whatever the product
  • Smart Diagnostics Suite gives early alerts for antenna build-up and abnormal surface conditions, which is the failure mode that matters in solids service

Key specifications

Accuracy
Performance class A ultra accuracy +/-1 mm (+/-0.04 in), or class S standard +/-2 mm (+/-0.08 in), under reference conditions. Maximum measuring range 98 ft (30 m)
Output signal
4-20 mA with HART 7. Optional HART Smart Diagnostics Suite, Smart Echo Level Test, and Smart Meter Verification professional, which allows remote verification and proof-testing from the control room without interrupting the process
Diagnostics
Smart Diagnostics Suite gives early alerts for antenna build-up or abnormal surface conditions. In solids service build-up is the real failure mode: material on the lens attenuates the signal gradually and the reading degrades into a plausible value rather than a fault
Pressure range
Sealed and lens antennas -1 to 25 bar (-15 to 363 psig) and -60 to 200 C (-76 to 392 F). The bracket mounted ATAP lens antenna is an open air version with a narrower envelope of -40 to 80 C
Variants
Three antenna types: lens antenna for small process fittings, process seal antenna with PTFE wetted parts, and the bracket mounted ATAP lens antenna for atmospheric open air service. SIL 2 certified to IEC 61508 and SIL 3 capable
Application
Tank and silo level where the reading participates in a safety function - overfill prevention, dry-run prevention, high and low level alarms - and solids level in silos and bins where the product sets the achievable range