Rosemount 400 / 400VP Endurance Conductivity Sensor
Purchase options
From$259.98
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Screw-in contacting conductivity sensor with titanium electrodes, 3/4 in MNPT connection, cell constants of 0.01, 0.1 or 1.0/cm and a Variopol quick-disconnect option.
Key features
- Contacting conductivity sensor with titanium electrodes and a PEEK insulator
- Cell constants of 0.01, 0.1 or 1.0/cm, factory measured
- 3/4 in MNPT process connection, 250 psig rating, vacuum to 1.6 in Hg
- 32 to 221 °F (0 to 105 °C) standard, to 392 °F (200 °C) with the integral junction box option
- Rosemount 400 with 10 ft integral cable, or 400VP with Variopol quick disconnect
- 316 stainless steel body, Viton O-ring, 16 micro-inch wetted finish
Key specifications
- Measurement principle
- Contacting (electrolytic) conductivity - titanium electrode pair with a glass-filled PEEK insulator and a 316 stainless steel body
- Process temperature
- 32 to 221 °F (0 to 105 °C) standard; 32 to 392 °F (0 to 200 °C) with the optional integral junction box
- Pressure rating
- 250 psig; suitable for vacuum service down to 1.6 in. Hg
- Process connection
- 3/4 in MNPT for direct insertion into a pipe tee; optional 24092-02 flow cell for side-stream sampling
- Wetted materials
- Titanium electrodes, glass-filled PEEK insulator, 316 stainless steel body and Viton O-ring; 16 micro-in. (0.4 um) Ra finish on all wetted surfaces
- Measurement range
- Clean, non-corrosive liquids with conductivity below 20,000 uS/cm
The workhorse contacting sensor
A screw-in conductivity sensor with a titanium electrode pair, a PEEK insulator and a 316 stainless body, threaded ¾ in MNPT so it goes directly into a pipe tee or a flow cell. It is the sensor to reach for when the water is clean and the question is simply how much dissolved ionic material is in it.
Three cell constants, three jobs
The 400 ships with a cell constant of 0.01, 0.1 or 1.0/cm, and the choice is decided by the conductivity band, not by preference. The 0.01 cell is for high purity water where the reading is a few microsiemens; the 0.1 cell covers the middle ground of boiler feedwater, reverse osmosis permeate and drinking water; the 1.0 cell is for clean cooling water and dilute chemistry approaching 20,000 µS/cm. Fit a 1.0 cell to a high purity loop and the reading disappears into the noise floor — the sensor is not faulty, it is simply the wrong one.
Why a contacting sensor here
Electrodes polarise in strong solutions and foul in dirty ones, which is exactly why toroidal sensors exist. Below 20,000 µS/cm in clean, non-corrosive liquid that problem does not arise, and the contacting cell is the more accurate and the simpler answer. The PEEK insulator and the 16 micro-inch finish on the wetted surfaces are what make it usable in a sanitary-adjacent line without giving anything up.
Two versions, one decision
The 400 has 10 ft of integral cable. The 400VP ends in a Variopol quick-disconnect, so the cable is a separate item and the sensor can be swapped without re-pulling it — the version to specify where sensors are removed for cleaning or verification. For long runs, option -60 adds an integral junction box and raises the top temperature from 221 °F to 392 °F (105 °C to 200 °C), with the interconnecting cable ordered separately.
Mounting and limits
Threads into a ¾ in MNPT tee, or into the 24092-02 flow cell for side-stream sampling. Rated 250 psig and suitable for vacuum down to 1.6 in Hg — the vacuum figure matters in condenser and deaerator service, where a sensor that is only pressure-rated will draw air past its seals. Keep the electrodes clean: a coating on titanium reads as a falling conductivity that looks like a process change.
Where it fits
High purity water, reverse osmosis, boiler and cooling water, and clean chemical streams — anywhere the conductivity is below 20,000 µS/cm and the fluid will not attack titanium or PEEK.
Manufacturer reference: Rosemount 400 and 400VP Contacting Conductivity Sensors Product Data Sheet, 00813-0100-3400 Rev AC.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Contacting (electrolytic) conductivity - titanium electrode pair with a glass-filled PEEK insulator and a 316 stainless steel body |
| Process temperature | 32 to 221 °F (0 to 105 °C) standard; 32 to 392 °F (0 to 200 °C) with the optional integral junction box |
| Pressure rating | 250 psig; suitable for vacuum service down to 1.6 in. Hg |
| Process connection | 3/4 in MNPT for direct insertion into a pipe tee; optional 24092-02 flow cell for side-stream sampling |
| Wetted materials | Titanium electrodes, glass-filled PEEK insulator, 316 stainless steel body and Viton O-ring; 16 micro-in. (0.4 um) Ra finish on all wetted surfaces |
| Measurement range | Clean, non-corrosive liquids with conductivity below 20,000 uS/cm |
| Cable connection | 10 ft integral cable on the 400; Variopol VP6 quick disconnect on the 400VP, with interconnecting cable ordered separately |
| Cell constant | 0.01, 0.1 or 1.0/cm, factory measured so no initial calibration is needed |
| Temperature sensor | Integral platinum resistance temperature device (RTD) for temperature measurement and compensation |
| Dimensions | 1 lb (0.5 kg) net, 2 lb (1.0 kg) shipping weight for the 400 with 10 ft cable |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.