Rosemount 404 Endurance Low Flow Conductivity Sensor
Purchase options
From$343.62
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Low-flow conductivity sensor with an integrated flow cell and a small hold-up volume, for clean liquids below 2,000 uS/cm where conductivity changes quickly.
Key features
- Integrated low-flow flow cell with a small hold-up volume for fast response
- Clean, non-corrosive liquids below 2,000 uS/cm
- Cell constants of 0.01 or 0.1/cm
- Polymer body (-16) to 140 F, or stainless steel body (-17) to 212 F that can be disassembled
- 3/8 in barbed tubing (-16) or 3/8 in compression fittings (-17) that leave 1/4 in NPT ports
- 10 ft integral cable standard, options to 100 ft
Key specifications
- Measurement principle
- Contacting conductivity in an integrated through-flow cell with a small hold-up volume, so the reading responds quickly to process changes
- Process temperature
- Option -16: 32 to 140 °F (0 to 60 °C); option -17: 32 to 212 °F (0 to 100 °C)
- Pressure rating
- Option -16: 100 psig (791 kPa abs) at 77 °F (25 °C), falling to 20 psig (239 kPa abs) at 140 °F (60 °C); option -17: 100 psig (791 kPa abs)
- Process connection
- Option -16: 3/8 in barbed tubing connector; option -17: compression fitting for 3/8 in OD tubing, removable to leave 1/4 in NPT ports
- Wetted materials
- Titanium electrodes, glass-filled PEEK insulator and EPDM O-ring; body and fittings in polyethylene (-16) or stainless steel (-17); 15 micro-in. (0.4 um) Ra finish
- Certifications
- Optional certificate of calibration (CC) for the sensor, or loop calibration certificate (LC) with the sensor and transmitter calibrated together and test data supplied
A sensor built as a flow cell
The 404 is not a probe that goes into a pipe — it is a small sidestream cell with the electrodes built into it. Sample enters one fitting and leaves the other, passing through a chamber with a very small hold-up volume, so the reading tracks a change in the process almost immediately instead of waiting for a pocket of old liquid to flush out.
Where the response time is the point
Most conductivity points are steady and any sensor will do. The 404 is for the ones that are not: a chromatography gradient, a rinse step where the water quality changes within seconds, a product/water interface moving down a line. In those applications a conventional sensor's hold-up volume is the dominant lag in the control loop, and the 404's small chamber is what removes it. The trade is that it must be installed as a sidestream sample — it is not an insertion sensor, and it will not take a dirty stream that would block a small chamber.
Two body materials, two temperature limits
Option -16 is the polymer cell, limited to 140 °F (60 °C) and 100 psig at room temperature — dropping to 20 psig at its top temperature — and it cannot be taken apart for cleaning. Option -17 is stainless steel, rated to 212 °F (100 °C) and 100 psig, and it can be disassembled. That difference decides the choice more often than the price: a hot CIP sample needs the stainless version, and a cold high-purity sample is fine in polymer.
Ranging
Cell constants of 0.01 and 0.1/cm, for clean non-corrosive liquids below 2,000 µS/cm. Note the ceiling: this cell is not for concentrated chemistry, and a line that swings above 2,000 µS/cm needs the toroidal family instead.
Plumbing it in
The -16 takes ⅜ in barbed tubing; the -17 takes ⅜ in compression fittings, which can be removed to leave ¼ in NPT ports if the sample line is threaded. Cable is 10 ft standard with integral options to 100 ft. Optional calibration certificates (CC for the sensor, LC for sensor and transmitter together) suit a validated system where the calibration has to be documented rather than just performed.
Where it fits
Chromatography and purification skids, pharmaceutical and food rinse lines, and any low-flow sample point below 2,000 µS/cm where the conductivity changes faster than a conventional sensor can follow.
Manufacturer reference: Rosemount 404 Contacting Conductivity Sensors Product Data Sheet, 00813-0100-3404 Rev AB.
Specifications
| Attribute | Value |
|---|---|
| Measurement principle | Contacting conductivity in an integrated through-flow cell with a small hold-up volume, so the reading responds quickly to process changes |
| Process temperature | Option -16: 32 to 140 °F (0 to 60 °C); option -17: 32 to 212 °F (0 to 100 °C) |
| Pressure rating | Option -16: 100 psig (791 kPa abs) at 77 °F (25 °C), falling to 20 psig (239 kPa abs) at 140 °F (60 °C); option -17: 100 psig (791 kPa abs) |
| Process connection | Option -16: 3/8 in barbed tubing connector; option -17: compression fitting for 3/8 in OD tubing, removable to leave 1/4 in NPT ports |
| Wetted materials | Titanium electrodes, glass-filled PEEK insulator and EPDM O-ring; body and fittings in polyethylene (-16) or stainless steel (-17); 15 micro-in. (0.4 um) Ra finish |
| Certifications | Optional certificate of calibration (CC) for the sensor, or loop calibration certificate (LC) with the sensor and transmitter calibrated together and test data supplied |
| Measurement range | Clean, non-corrosive liquids with conductivity below 2,000 uS/cm |
| Cable connection | 10 ft (3 m) integral cable standard; integral 15, 20, 33, 50 and 100 ft options |
| Cell constant | 0.01 or 0.1/cm |
| Dimensions | 2 lb (1.0 kg) net for the -16 and 4 lb (2.0 kg) for the -17, with the 10 ft cable |