Overview
Coplanar pressure transmitter with 0.025 percent span Ultra accuracy, 200:1 rangedown, 20-year stability and a 40 ms response option.
Key features
- Coplanar differential, gauge or absolute pressure transmitter with an Ultra class quoting 0.025 percent of span accuracy and 20-year stability with a matching twenty-year limited warranty
- The performance classes pair accuracy with a turndown: Ultra 0.025 percent of span at 200:1, Ultra-For-Flow 0.04 percent of reading at 200:1, Classic 0.035 percent of span at 150:1. The 800:1 rangedown in the feature list is the platform's stock-keeping claim, not the accuracy class
- Accuracy degrades with turndown by a published equation: below ten to one, Ultra Coplanar ranges 2 to 4 become plus or minus (0.005 + 0.0035 x URL/Span) percent of span, which is 0.18 percent at 50:1 and 0.705 percent at 200:1
- At deep turndown the absolute error is still small because the span is small, but the effects that are not span-relative - static pressure zero shift, ambient temperature, mounting - are no longer small against that span
- Range U shows the cliff explicitly: spans beyond 200:1 switch to an equation whose fixed term is 0.615 instead of 0.005
- 40 ms time response option for compressor surge, hydraulic transients and test stands, where the pressure is the event rather than a condition. Bluetooth for configuration in hazardous areas, and level, volume, flow or totalized flow configured in the device
Key specifications
- Accuracy
- Ultra 0.025 percent of span on Coplanar DP ranges 2 to 4; Classic 0.035 percent of span; Ultra-For-Flow 0.04 percent of READING (not span) for flow. The accuracy degrades with turndown by a published equation: for spans below 10:1 the Ultra Coplanar DP figure becomes plus or minus (0.005 + 0.0035 x URL/Span) percent of span, which is 0.040 percent at 10:1, 0.180 percent at 50:1 and 0.705 percent at 200:1. On Range U, spans beyond 200:1 switch to an equation whose fixed term is 0.615 rather than 0.005
- Output signal
- 4-20 mA with HART digital signal, with Bluetooth connectivity for configuration and service in hazardous locations. The transmitter can be configured for pressure, level, volume, flow or totalized flow in the device rather than in the control system
- Diagnostics
- One electronics platform across Coplanar pressure, In-line pressure, the 4051SF flow meter and the 4051SLT level transmitter, so a site standardises on one configuration tool and one set of diagnostics. At deep turndown the effects that are not span-relative - static pressure zero shift, ambient temperature effect, mounting stress - are no longer small compared with the span, and they are what decides whether the loop holds
- Pressure range
- Range codes from Range 0 through Range 5 plus Range U, in differential, gauge and absolute variants. Rangedown is 200:1 in the Ultra class, 150:1 in Classic - the 800:1 in the feature list is the platform's stock-keeping claim across range codes, not the turndown of one accuracy class
- Application
- Differential pressure across filters, flow elements and columns; gauge pressure on process lines; absolute pressure on vacuum and distillation service; and level by hydrostatic head. Coplanar sensor module with a manifold bolted directly to the transmitter body
- Operating temperature (°C)
- Process and ambient limits are set by the sensor module and fill fluid selected; the electronics housing carries the hazardous-area marking on its bezel. A manifold and impulse lines add their own temperature exposure to the assembly
0.025 %, 200:1 and 800:1 are three different promises
The Rosemount 4051S Coplanar is a differential, gauge or absolute pressure transmitter with an Ultra performance class quoting 0.025 % of span, 20-year stability backed by a twenty-year warranty, a 40 ms time response option, Bluetooth configuration, and a platform that also covers in-line pressure, flow (4051SF) and level (4051SLT).
The feature list also says "800:1 rangedown reduces the number of unique models you need to stock". All three numbers are real and they do not describe the same instrument, which is worth getting straight before a specification is written.
The classes pair accuracy with a turndown
| Class | Accuracy | Rangedown |
|---|---|---|
| Ultra | 0.025 % of span | 200:1 |
| Ultra-For-Flow | 0.04 % of reading | 200:1 DP turndown |
| Classic | 0.035 % of span | 150:1 |
Note where the Ultra-For-Flow entry says reading rather than span. Those are different claims, and on a flow application — where the differential falls with the square of flow — a percentage of reading is the one that matters and a percentage of span is the one that flatters. The 800:1 is the platform's stock-keeping claim across the range codes; the accuracy figure belongs to a class, and the class tops out at 200:1.
What happens to accuracy at deep turndown
The datasheet does not hide this, and it is the most useful table in the document. For Coplanar DP ranges 2 to 4 in the Ultra class, the reference accuracy is ±0.025 % of span — and then, for spans below ten to one, it becomes an equation:
±(0.005 + 0.0035 × [URL / Span]) % of span
Work it through and the shape is clear:
| Turndown | Accuracy as % of span |
|---|---|
| Up to 10:1 | 0.025 % |
| 20:1 | 0.075 % |
| 50:1 | 0.180 % |
| 100:1 | 0.355 % |
| 200:1 | 0.705 % |
So a transmitter bought as "0.025 %" and ranged at 100:1 is a 0.36 % instrument in the units the datasheet used. That is the arithmetic the spec sheet is asking you to do, and it is why "0.025 % and 200:1" cannot be quoted as one capability.
Now the other half, because it would be dishonest to stop here: at 100:1 the span is a hundred times smaller, so 0.355 % of that span is a very small number in inches of water or bar. Deep turndown costs accuracy relative to span and usually still delivers a smaller absolute uncertainty than a wide-range transmitter would. What it takes away is the right to compare your installation with a shallow-span one on the datasheet's headline percentage — and what it really changes is the weight of everything that is not span-relative: zero shift from static pressure, ambient temperature effect, mounting. At 200:1 those effects are no longer small compared with the span, and they are the ones that decide whether the loop holds.
Range U shows the cliff
One range code makes the point better than any explanation. On Range U in the Ultra class, spans from 10:1 to 200:1 use the familiar equation — and then a second line covers spans beyond 200:1 at ±(0.615 + 0.0005 [URL/Span]). The constant jumps from 0.005 to 0.615: a hundredfold change in the fixed term, at the exact point where the turndown passes 200:1.
That is what a turndown limit looks like when it is written down. It is not a marketing boundary; it is the point where the sensor's resolution stops being able to resolve the span, and the vendor publishes the equation rather than pretending the limit is not there.
40 milliseconds, and who needs it
The standard update rate is adequate for tanks, columns and most process loops. The 40 ms time response option exists for the processes that are faster than the control system reading them — compressor surge, hydraulic transients, fast packaging and test stands, and any loop where the pressure is the event rather than a condition. Specifying it on a level application adds cost for a speed nobody can use; leaving it off a surge application means the trip is late by design.
Twenty years, and what it is really promising
20-year stability with a matching twenty-year limited warranty is a statement about drift, and drift is the reason pressure transmitters get pulled for calibration. If the zero does not move, the calibration interval stops being a maintenance default and becomes a decision about the process — the same argument as the 0.025 % figure, applied to time instead of to span.
One platform, four measurements
The 4051S family is deliberately one electronics package on several sensor modules: Coplanar for differential, gauge and absolute pressure, In-line for direct-mount pressure with a simpler body, 4051SF as a complete differential pressure flow meter, and 4051SLT as a level transmitter. On a site that standardises, that means one configuration tool, one set of diagnostics and one spare — and it is also why the transmitter can be configured for level, volume, flow or totalized flow in the device rather than in the control system.
Bluetooth matters here for the same reason it matters on a temperature transmitter: the devices are mounted at the top of a column, behind a manifold, or inside an enclosure that has to be opened to reach a display. Reading a transmitter that shows its value and its Bluetooth state on the local display, without breaking a hazardous-area seal to do it, is a maintenance improvement rather than a feature.
Where it fits
Differential pressure across filters, flow elements and columns; gauge pressure on process lines; absolute pressure on vacuum and distillation service; level by hydrostatic head. Specify the performance class from the uncertainty the loop actually needs, then range it — and when the range is deep, quote the accuracy the equation gives at that turndown, not the one on the front page.
Manufacturer reference: Rosemount 4051S Pressure Transmitter Product Data Sheet for the performance classes, the reference accuracy equations by range and class, static pressure and temperature effects, response options and ordering codes.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Ultra 0.025 percent of span on Coplanar DP ranges 2 to 4; Classic 0.035 percent of span; Ultra-For-Flow 0.04 percent of READING (not span) for flow. The accuracy degrades with turndown by a published equation: for spans below 10:1 the Ultra Coplanar DP figure becomes plus or minus (0.005 + 0.0035 x URL/Span) percent of span, which is 0.040 percent at 10:1, 0.180 percent at 50:1 and 0.705 percent at 200:1. On Range U, spans beyond 200:1 switch to an equation whose fixed term is 0.615 rather than 0.005 |
| Output signal | 4-20 mA with HART digital signal, with Bluetooth connectivity for configuration and service in hazardous locations. The transmitter can be configured for pressure, level, volume, flow or totalized flow in the device rather than in the control system |
| Diagnostics | One electronics platform across Coplanar pressure, In-line pressure, the 4051SF flow meter and the 4051SLT level transmitter, so a site standardises on one configuration tool and one set of diagnostics. At deep turndown the effects that are not span-relative - static pressure zero shift, ambient temperature effect, mounting stress - are no longer small compared with the span, and they are what decides whether the loop holds |
| Pressure range | Range codes from Range 0 through Range 5 plus Range U, in differential, gauge and absolute variants. Rangedown is 200:1 in the Ultra class, 150:1 in Classic - the 800:1 in the feature list is the platform's stock-keeping claim across range codes, not the turndown of one accuracy class |
| Application | Differential pressure across filters, flow elements and columns; gauge pressure on process lines; absolute pressure on vacuum and distillation service; and level by hydrostatic head. Coplanar sensor module with a manifold bolted directly to the transmitter body |
| Operating temperature (°C) | Process and ambient limits are set by the sensor module and fill fluid selected; the electronics housing carries the hazardous-area marking on its bezel. A manifold and impulse lines add their own temperature exposure to the assembly |
| Response time | Standard update rate for tanks, columns and normal process loops, with a 40 ms time response option for compressor surge, hydraulic transients, packaging and test stands - the loops where the pressure is the event rather than a condition |
| Stability | 20-year stability with a matching twenty-year limited warranty. Stability is a claim about drift, and drift is the reason pressure transmitters get pulled for calibration, so the interval becomes a decision about the process rather than a default |