Rosemount 4051SFP Integral Orifice Flow Meter

Part number4051SFPManufacturerEmerson

Purchase options

From$1,764.54

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Integral orifice flow meter with plate, manifold and transmitter in one body: no impulse lines, 0.8 percent flow accuracy at 14:1 turndown.

Key features

  • Integral orifice flow meter: orifice plate, manifold and 4051S differential pressure transmitter assembled in one body, configured at the factory for the application and reporting flow directly on the display
  • There are no impulse lines, so the failure mode of a plugged, frozen or wrongly filled leg cannot happen - the differential is taken inside the body a few centimetres from the diaphragms
  • Because the body is rigid, orientation becomes the installation: gas in a horizontal pipe mounts above it so condensate runs back, liquid or steam mounts below so gas bubbles rise away, vertical liquid must flow up and vertical gas must flow down
  • Vertical liquid flowing down and vertical gas flowing up cannot use direct mount at all and require a remote mounted transmitter, which is a model code decision rather than a site instruction
  • Direct mount is specified from -40 to 450 F (-40 to 232 C); above that the transmitter moves off the body onto a remote mount with the adapter giving 2, 2-1/8 or 2-1/4 in connection centres on the 1/2 in NPT ports
  • Straight lengths are multiples of the pipe inside diameter measured from the upstream face of the orifice plate, not from the flange, and sizing depends on the true pipe inside diameter. A three or five valve manifold is required for direct mounting

Key specifications

Accuracy
Ultra-For-Flow 0.8 percent flow rate accuracy with 14:1 flow turndown, or 28:1 with the universal pressure range option. Classic 1.25 percent flow rate at 8:1. Because flow follows the square root of differential pressure, a 14:1 flow turndown is a 196:1 turndown of differential
Output signal
4-20 mA with HART and Bluetooth on the 4051S platform, configured at the factory for the application and reporting volumetric flow, mass flow or totalized flow directly on the display. Two integral relay switches available
Diagnostics
The integral body removes the failure mode of a plugged, frozen or wrongly filled impulse line, because there are no legs - the differential is taken inside the body a few centimetres from the diaphragms. What replaces it is an orientation constraint that cannot be corrected after installation by re-routing anything, only by remote mounting the transmitter. A pipeline that has been re-rated or lined also changes the true inside diameter the plate was sized for, which shows up as a flow reading consistently a few percent off that no calibration removes
Pressure range
Set by the 4051S sensor module range code and the body and connection ratings. Direct mounting is specified over -40 to 450 F (-40 to 232 C); above that the transmitter must be remote mounted
Application
Flow measurement on small lines where a full orifice run would be disproportionate and the line is too small for an insertion probe: utilities, chemical dosing, steam to a small user, cooling water to a single machine and gas to a burner
Mounting
The body is rigid, so orientation is the installation: gas in a horizontal pipe mounts above it within a 90 degree zone so condensate runs back into the line, liquid or steam mounts below it so gas bubbles rise away, vertical liquid is only acceptable with flow upward, and vertical gas only with flow downward. Vertical steam must be remote mounted, and a three or five valve manifold is required when the transmitter is direct mounted